The paper describes measurement and calculation of 2D distribution of the vibration signal originated by the gradient coil system of the magnetic resonance imaging (MRI) equipment. The measurement experiments were performed at the bottom plastic holder of the scanning area of the open-air weak magnetic field MRI device. Selection of a usable type of a vibration sensor for measurement in a magnetic field with low B0 up to 0.2 T is also discussed. Realized calibration of the chosen sensor (sensitivity and frequency response) together with determination of the propagation time delay between the excitation impulses and the subsequently generated vibration signal is mentioned, too. The picked-up vibration signal exhibits harmonic character so it is suitable to describe it by determined spectral properties and features. Obtained statistical results of spectral analysis will be used to improve image sharpening and reduction of the motion effect in the MR pictures of thin layer samples and phantoms scanned by this MRI system.

References

1.
van den Brink
,
J. S.
,
Watanabe
,
Y.
,
Kuhl
,
C. K.
,
Chung
,
T.
,
Muthupillai
,
R.
,
van Cauteren
,
M.
,
Yamada
,
K.
,
Dymarkowski
,
S.
,
Bogaert
,
J.
,
Maki
,
J. H.
,
Matos
,
C.
,
Casselman
,
J. W.
, and
Hoogeveen
,
R. M.
,
2003
, “
Implications of SENSE MR in Routine Clinical Practice
,”
Eur. J. Radiol.
,
46
(
1
), pp.
3
27
.10.1016/S0720-048X(02)00333-9
2.
Bertram
,
H. C.
,
Rasmussen
,
M.
,
Busk
,
H.
,
Oksbjerg
,
N.
,
Karlsson
,
A. H.
, and
Andersen
,
H. J.
,
2002
, “
Changes in Porcine Muscle Water Characteristics During Growth—An In Vitro Low-Field NMR Relaxation Study
,”
J. Magn. Reson.
,
157
(
2
), pp.
267
276
.10.1006/jmre.2002.2600
3.
Thybo
,
A. K.
,
Andersen
,
H. J.
,
Karlsson
,
A. H.
,
Dønstrup
,
S.
, and
Stødkilde-Jørgensen
,
H.
,
2003
, “
Low-Field NMR Relaxation and NMR-Imaging as Tools in Differentiation Between Potato Sample and Determination of Dry Matter Content in Potatoes
,”
LWT—Food Sci. Technol.
,
36
(
3
), pp.
315
322
.10.1016/S0023-6438(02)00210-4
4.
du Trémolet de Lacheisserie
,
É.
,
Gignoux
,
D.
, and
Schlenker
,
M.
,
2005
,
Magnetism: Fundamentals
,
Springer Science + Business Media
, Berlin.
5.
Moelker
,
A.
,
Wielopolski
,
P. A.
, and
Pattynama
,
M. T.
,
2003
, “
Relationship Between Magnetic Field Strength and Magnetic-Resonance-Related Acoustic Noise Levels
,”
Mag. Reson. Mater. Phys., Biol. Med.
,
16
(
1
), pp.
52
55
.10.1007/s10334-003-0005-9
6.
Frollo
,
I.
,
Andris
,
P.
,
Přibil
,
J.
, and
Juráš
,
V.
,
2007
, “
Indirect Susceptibility Mapping of Thin-Layer Samples Using Nuclear Magnetic Resonance Imaging
,”
IEEE Trans. Magn.
,
43
(
8
), pp.
3363
3367
.10.1109/TMAG.2007.900571
7.
Oveisi
,
A.
,
Gudarzi
,
M.
,
Mohammadi
,
M. M.
, and
Doosthoseini
,
A.
,
2013
, “
Modeling, Identification and Active Vibration Control of a Funnel-Shaped Structure Used in MRI Throat
,” J. Vibroeng.,
15
(
1
), pp.
438
449
, available at: http://jve.lt/Vibro/JVE-2013-15-1/JVE-2013-15-1-961.pdf
8.
Rudd
,
B. W.
,
Lee
,
J. H.
,
Lim
,
T. C.
, and
Li
,
M.
,
2012
, “
In Situ Active Noise Cancellation Applied to Magnetic Resonance Imaging
,”
ASME J. Vib. Acoust.
,
134
(
1
), p.
011017
.10.1115/1.4005008
9.
Baker
,
M. A.
,
2013
, “
Reduction of MRI Acoustic Noise Achieved by Manipulation of Scan Parameters—A Study Using Veterinary MR Sequences
,”
Radiography
,
19
(
1
), pp.
11
16
.10.1016/j.radi.2012.09.004
10.
E-scan Opera,
2008
,
Image Quality and Sequences Manual
, 830023522
Rev. A, Esaote
,
Genova, Italy
.
11.
Kwak
,
M. K.
, and
Yang
,
D. H.
,
2013
, “
Active Vibration Control of a Ring-Stiffened Cylindrical Shell in Contact With Unbounded External Fluid and Subjected to Harmonic Disturbance by Piezoelectric Sensor and Actuator
,”
J. Sound Vib.
,
332
(
20
), pp.
4775
4797
.10.1016/j.jsv.2013.04.014
12.
Žiaran
,
S.
, and
Darula
,
R.
,
2013
, “
Determination of the State of Wear of High Contact Ratio Gear Sets by Means of Spectrum and Cepstrum Analysis
,”
ASME J. Vib. Acoust.
,
135
(
2
), pp.
1
10
.10.1115/1.4023208
13.
Fraden
,
J.
,
2010
,
Handbook of Modern Sensors. Physics, Designs, and Applications
, 4th ed.,
Springer
,
New York
.
14.
Niedżwiecki
,
M.
, and
Meller
,
M.
,
2013
, “
Generalized Adaptive Comb Filters/Smoothers and Their Application to the Identification of Quasi-Periodically Varying Systems and Signals
,”
Automatica
,
49
(
6
), pp.
1601
1613
.10.1016/j.automatica.2013.02.037
15.
Sierra
,
C. V. R.
,
Versluis
,
M. J.
,
Hoogduin
,
J. M.
, and
Duifhuis
,
H. D.
,
2008
, “
Acoustic fMRI Noise: Linear Time-Invariant System Model
,”
IEEE Trans. Biomed. Eng.
,
55
(
9
), pp.
2115
2123
.10.1109/TBME.2008.923112
16.
Borza
,
D. N.
,
2011
, “
Vibration Measurement by Speckle Interferometry Between High Spatial and High Temporal Resolution
,”
Holography, Research, and Technologies
,
J.
Rosen
, ed.,
InTech
,
Rjeka, Croatia
, pp.
325
346
.
17.
Phidgets 1104,
2009
,
Vibration Sensor Product Manual
,
Phidgets, Inc.
,
Calgary, Canada
.
18.
Raitio
,
T.
,
Suni
,
A.
,
Vainio
,
M.
, and
Alku
,
P.
,
2013
, “
Synthesis and Perception of Breathy, Normal, and Lombard Speech in the Presence of Noise
,”
Comput. Speech Lang.
,
28
(
2
), pp.
648
664
.10.1016/j.csl.2013.03.003
19.
Misra
,
H.
,
Ikbal
,
S.
,
Sivadas
,
S.
, and
Bourlard
,
H.
,
2005
, “
Multi-Resolution Spectral Entropy Feature for Robust ASR
,”
IEEE International Conference on Acoustics, Speech, and Signal Processing
(
ICASSP’05
), Philadelphia, PA, March 18–23, pp.
253
256
.10.1109/ICASSP.2005.1415098
20.
Le
,
P. N.
,
Ambikairajah
,
E.
,
Epps
,
J.
,
Sethu
,
V.
, and
Choi
,
E. H. C.
,
2011
, “
Investigation of Spectral Centroid Features for Cognitive Load Classification
,”
Speech Commun.
,
53
(
4
), pp.
540
551
.10.1016/j.specom.2011.01.005
21.
Madhu
,
N.
,
2009
, “
Note on Measures for Spectral Flatness
,”
Electron. Lett.
,
45
(
23
), pp.
1195
1196
.10.1049/el.2009.1977
22.
Sinha
,
J. K.
,
2005
, “
On Standardisation of Calibration Procedure for Accelerometer
,”
J. Sound Vib.
,
286
(
1–2
), pp.
417
427
.10.1016/j.jsv.2004.12.004
23.
Frollo
,
I.
,
Andris
,
P.
,
Přibil
,
J.
,
Dermek
,
T.
, and
Gogola
,
D.
,
2013
, “
Soft Magnetic Material Testing Using Magnetic Resonance Imaging
,”
Adv. Mater. Res.
,
740
, pp.
618
623
.10.4028/www.scientific.net/AMR.740.618
You do not currently have access to this content.