Background: The occurrence of multi-directional sliding motion between total knee replacement bearing surfaces is theorized to be a primary wear and failure mechanism of ultra-high molecular weight poly(ethylene) (UHMWPE). To better quantify the tribologic mechanisms of this cross-shear wear, the MAX-Shear wear-testing system was developed to evaluate candidate biomaterials under controlled conditions of cross-shear wear. Method of approach: A computer controlled traveling x-y stage under a 3 degree-of-freedom statically loaded pin is used to implement the complex multi-directional motion pathways observed during TKR wear simulation. A MHz collection of dynamic x-y friction was available on all six environmentally controlled stations. The functionality of this testing platform was proven in a 100,000 cycle, 11.6 MPa, wear test using 15.0 mm diameter polished stainless steel spheres against flat GUR4150 UHMWPE. A five-pointed star wear pattern was used to incorporate the physiologically relevant cross-shear sliding conditions of stop/start, 50mms entraining velocity and five crossing angles of 72°. Using normalized volumetric reconstruction of the resulting surface damage, a direct quantitative relationship between linear and cross-shear surface damage intensity was obtained. Results: Cross-shear surface damage volume loss was found to be 2.94 (±0.88) times that associated with linear sliding under identical tribologic conditions. SEM analysis of linear wear damage showed consistent fibril orientation along the direction of sliding while cross-shear wear damage showed multi-directional fibril orientations and increased surface roughness. Significant increases in discrete crossing-point friction coefficients were recorded throughout testing. Conclusions: This scientific approach to quantifying the tribologic effects of cross-shear provides fundamental wear mechanism data that are critical in evaluating potential biomaterials for use as in vivo bearings. Relevant multi-axis, cross-shear wear testing is necessary to provide quantifiable measures of complex biomaterials wear phenomena.

1.
McGloughlin
T. M.
, and
Kavanagh
,
A. G.
, 2000, “
Wear of Ultra-High Molecular Weight Polyethylene (UHMWPE) in Total Knee Prostheses: A Review of Key Influences
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
214
(
H4
), pp.
349
359
.
2.
Bradgon
,
C. R.
,
O’Connor
,
D. O.
,
Lowenstein
,
J. D.
,
Jasty
,
M.
, and
Syniuta
,
W. D.
, 1996, “
The Importance of Multidirectional Motion on the Wear of Polyethylene
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
210
(
H3
), pp.
157
165
.
3.
Blunn
,
G. W.
,
Walker
,
P. S.
,
Joshi
,
A.
, and
Hardinge
,
K.
, 1991, “
The Dominance of Cyclic Sliding in Producing Wear in Total Knee Replacements
,”
Clin. Orthop. Relat. Res.
0009-921X,
273
, pp.
253
260
.
4.
Wang
,
A.
,
Stark
,
C.
, and
Dumbleton
,
J. H.
, 1996, “
Mechanistic and Morphological Origins of Ultra-High Molecular Weight Polyethylene Wear Debris in Total Joint Replacement Prostheses
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
210
(
H3
), pp.
141
155
.
5.
Johnson
,
T.
,
Andriacchi
,
T.
,
Laurent
,
M.
,
Yao
,
J.
, and
Mclean
,
C.
, 2001, “
An in Vivo Based Knee Wear Test Protocol Incorporating a Heel Strike Slip Velocity Transient
,”
Trans. Annu. Meet. \M Orthop. Res. Soc.
0149-6433,
26
, p.
1006
.
6.
DesJardins
,
J.
,
Caroll
,
M.
, and
LaBerge
,
M.
, 2002, “
Tracking TKR Design Dynamic Pivot Locations During Force-Controlled TKR Wear Simulation
,”
Trans. Soc. Biomater.
,
25
, p.
718
.
7.
DesJardins
,
J.
,
Banks
,
S.
, and
LaBerge
,
M.
, 2002, “
Validation of TKR Wear Testing Contact Sliding Velocities Using in Vivo TKR Fluoroscopy
,”
Trans. Annu. Meet. \M Orthop. Res. Soc.
0149-6433,
27
, p.
0959
.
8.
DesJardins
,
J.
,
Banks
,
S.
, and
LaBerge
,
M.
, 2001, “
A Direct Comparison of Patient and Simulator Total Knee Replacement Kinematics
,”
Trans. Annu. Meet. \M Orthop. Res. Soc.
0149-6433,
26
,
1096
.
9.
Sawyer
,
W. G.
,
Hamilton
,
M. A.
,
Sucec
,
M. C.
,
Fregly
,
B. J.
, and
Banks
,
S. A.
, 2003, “
Analysis of in Vivo Crossing Motion in Total Knee Replacements
,” Summer Bioengineering Conference, Key Biscayne, FL, 0549, http://www.tulane.edu/~sbc2003/pdfdocs/0549.PDFhttp://www.tulane.edu/~sbc2003/pdfdocs/0549.PDF
10.
DesJardins
,
J.
, and
LaBerge
,
M.
, 2002, “
Force-Controlled TKR Wear Simulation Produces Complex Cross-Shear Kinematics
,”
Trans. Soc. Biomater.
,
25
,
711
.
11.
Johnson
,
K. L.
, 1987,
Contact Mechanics
,
Cambridge University Press
, Cambridge, UK.
12.
Szivek
,
J. A.
,
Anderson
,
P. L.
, and
Benjamin
,
J. B.
, 1996, “
Average and Peak Contact Stress Distribution Evaluation of Total Knee Arthroplasties
,”
J. Arthroplasty
0883-5403,
11
(
8
), pp.
952
963
.
13.
Bartel
,
D. L.
,
Bicknell
,
V. L.
, and
Wright
,
T. M.
, 1986, “
The Effect of Conformity, Thickness, and Material on Stresses in Ultrahigh Molecular-Weight Components for Total Joint Replacement
,”
J. Bone Jt. Surg., Am. Vol.
0021-9355 Vol.,
68
(
7
), pp.
1041
1051
.
14.
Calonius
,
O.
, and
Saikko
V.
, 2002, “
Slide Track Analysis of Eight Contemporary Hip Simulator Designs
,”
J. Biomech.
0021-9290,
35
, pp.
1439
1450
.
15.
Fischer
,
D. A.
,
Sambasivan
,
S.
,
Shen
,
M. C.
, and
Hsu
,
S. M.
, 1999, “
Wear Induced Molecular Orientation in UHMWPE Measured by Soft X-ray Absorption
,”
Trans. Soc. Biomater.
,
22
, p.
194
.
16.
Saikko
,
V.
, 1997, “
A Multi-Directional Motion Pin-On-Disk Test Method for Prosthetic Joint Materials
,”
J. Biomed. Mater. Res.
0021-9304,
41
, pp.
58
64
.
17.
Bradgon
,
C. R.
,
O’Connor
,
D. O.
,
Lowenstein
,
J. D.
,
Jasty
,
M.
,
Biggs
,
S. A.
, and
Harris
,
W. H.
, 2001, “
A New Pin-On-Disk Wear Testing Method for Simulating Wear of Polyethylene on Cobalt-Chrome Alloy in Total Hip Arthoplasty
,”
J. Arthroplasty
0883-5403,
16
(
5
), pp.
658
665
.
18.
Wang
,
A.
, 2000, “
A Unified Theory of Wear for Ultra-High Molecular Weight Polyethylene in Multi-Directional Sliding
,”
Wear
0043-1648,
248
, pp.
38
47
.
19.
Joyce
,
T. J.
,
Vandelli
,
C.
,
Cartwright
,
T.
, and
Unsworth
,
A.
, 2001, “
A Comparison of the Wear of Cross-Linked Polyethylene Against Itself Under Reciprocating and Multi-Directional Motion with Different Lubricants
,”
Wear
0043-1648,
250
, pp.
206
211
.
20.
Turell
,
M.
,
Wang
,
A. G.
, and
Bellare
,
A.
, 2003, “
Quantification of the Effect of Cross-Path Motion on the Wear Rate of Ultra-High Molecular Weight Polyethylene
,”
Wear
0043-1648,
255
(
2
), pp.
1034
1039
.
21.
Toohey
,
K. S.
,
Blanchet
,
T. A.
, and
Heckelman
,
D. D.
, 2003, “
Effect of Accelerated Aging Conditions on Resultant Depth-Dependent Oxidation and Wear Resistance of UHMWPE Joint Replacement Bearing Materials
,”
Wear
0043-1648,
255
, pp.
1076
1084
.
22.
Sambasivan
,
S.
,
Fischer
,
D. A.
,
Chen
,
M. C.
, and
Hsu
,
S. M.
, 2004, “
Molecular Orientation of Ultrahigh Molecular Weight Polyethylene Induced by Various Sling Motions
,”
J. Biomed. Mater. Res., Part B: Appl. Biomater.
1552-4973,
70
(
B
), pp.
278
285
.
23.
Yao
,
J. Q.
,
Blanchet
,
T. A.
,
Murphy
,
D. J.
, and
Laurent
,
M. P.
, 2003, “
Effect of Fluid Absorption on the Wear Resistance of UHMWPE Orthopedic Bearing Surfaces
,”
Wear
0043-1648,
255
, pp.
1113
1120
.
24.
Saikko
,
V.
, and
Calonius
,
O.
, 2002, “
Slide Track Analysis of the Relative Motion between Femoral Head and Acetabular Cup in Walking and in Hip Simulators
,”
J. Biomech.
0021-9290,
35
, pp.
455
464
.
25.
Fregly
,
B. J.
,
Sawyer
,
W. G.
,
Harman
,
M. K.
, and
Banks
,
S. A.
, 2004, “
Computational Wear Prediction of Total Knee Replacement from in Vivo Kinematics
,”
J. Biomech.
0021-9290,
38
(
2
), pp.
305
314
.
26.
DesJardins
,
J. D.
,
Benson
,
L. C.
,
Gustafson
,
L. M.
, and
LaBerge
,
M.
, 2005, “
Fiberscopic Visualization of Total Knee Replacement Contact Kinematics During In Vitro Simulation
,”
Trans. World Tribology Congress
3
, p.
63699
.
27.
Benson
,
L. C.
,
DesJardins
,
J. D.
,
Harman
,
M. K.
, and
LaBerge
,
M.
, 2002, “
Effect of Stair Descent Loading on Ultra-High Molecular Weight Polyethylene Wear in a Force-controlled Knee Simulator
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
216
(
6
), pp.
409
418
.
28.
Wang
,
A.
,
Sun
,
D.
,
Yau
,
S.-S.
,
Edwards
,
B.
,
Sokol
,
M.
,
Essner
,
A.
,
Polineni
,
V.
,
Stark
,
C.
, and
Dumbleton
,
J. H.
, 1997, “
Orientation Softening in the Deformation and Wear of Ultra-High Polyethylene
,”
Wear
0043-1648,
203
, pp.
230
241
.
29.
Ramamurthi
,
B.
,
Bragdon
,
C.
,
O’Connor
,
D.
,
Lowenstein
,
J.
,
Jasty
,
M.
,
Estok
,
D.
, and
Harris
,
W.
, 1996, “
Loci of Movement of Selected Points on the Femoral Head During Normal Gait
,”
J. Arthroplasty
0883-5403,
11
(
7
) pp.
852
855
.
30.
Wang
,
A.
,
Essner
,
A.
,
Stark
,
C.
, and
Dumbleton
,
J. H.
, 1999, “
A Biaxial Line-Contact Wear Machine for the Evaluation of Bearing Materials for Total Knee Joint Replacement
,”
Wear
0043-1648,
229
, pp.
701
707
.
31.
Johnson
,
T. S.
,
Laurent
,
M. P.
,
Yao
,
J. Q.
, and
Gilbertson
,
L. N.
, 2001, “
The Effect of Displacement Control Input Parameters on Tibiofemoral Prosthetic Knee Wear
,”
Wear
0043-1648,
250
, pp.
222
226
.
32.
Sawyer
,
W. G.
,
Hamilton
,
M. A.
,
Sucec
,
M. C.
,
Fregly
,
B. J.
, and
Banks
,
S. A.
, 2003, “
Mapping Multidirectional Sliding Motions on the Tibial Component of Total Knee Replacements Using Patient Specific Kinematics
,”
Proceedings of the ASME/STLE International Joint Tribology Conference
,
Ponte Vedra Beach
, FL.
You do not currently have access to this content.