The electrical power generated by a polycrystalline silicon photovoltaic (PV) module mounted on an unglazed transpired solar collector (UTC) has been studied and compared to that of a PV module without UTC for a quantitative analysis of electrical output and its role in reducing the simple payback periods of photovoltaic electrical systems. A 75W polycrystalline silicon PV module was fixed on an UTC in front of the ventilation fan, and effectiveness of cooling by means of the forced ventilation at the rate of 160CFM was monitored. The temperature reduction under forced ventilation was in the range of 3-9°C with a 5% recovery in the electrical output power on a typical day of the month of February 2005. The simulated and measured electrical power outputs are in reasonable agreement with root-mean-square error of 2.40. The life cycle assessment of a hypothetical PV system located at Daejeon, South Korea and consisting of 3kW PV modules fixed on a 50m2 UTC shows that with a possible reduction of 3-9°C in the operating temperatures, the system requires three 75W fewer PV modules. The simple payback period of PV system is reduced from 23yearsto15years when integrated into an UTC air heating system.

1.
Radziemska
,
E.
, 2003, “
The Effect of Temperature on the Power Drop in Crystalline Silicon Solar Cells
,”
Renewable Energy
0960-1481,
28
(
1
), pp.
1
12
.
2.
Brinkworth
,
B. J.
,
Cross
,
B. M.
,
Marshall
,
R. H.
, and
Yang
,
H.
, 1997, “
Thermal Regulations of Photovoltaic Claddings
,”
Sol. Energy
0038-092X,
61
(
3
), pp.
169
178
.
3.
Zakharchenko
,
R.
,
Licea-Jiménez
,
L.
,
Pérez-García
,
S. A.
,
Vorobiev
,
P.
,
Dehesa-Carrasco
,
U.
,
Pérez-Robles
,
J. F.
,
Gonzalez-Hernández
,
J.
, and
Vorobiev
,
Yu.
, 2004, “
Photovoltaic Solar Module for a Hybrid PV∕Thermal System
,”
Sol. Energy Mater. Sol. Cells
0927-0248,
82
(
1–2
), pp.
253
261
.
4.
Hollick
,
J. C.
, 1994, “
Unglazed Solar Wall Air Heaters
,”
Renewable Energy
0960-1481,
5
(
1–4
), pp.
415
421
.
5.
Gunnewiek
,
L. H.
,
Brundrett
,
E.
, and
Hollands
,
K. G. T.
, 1996, “
Flow Distribution in Unglazed Transpired Plate Solar Air Heaters of Large Area
,”
Sol. Energy
0038-092X,
58
(
4–6
), pp.
227
237
.
6.
Kutscher
,
C. F.
, 1994, “
Heat Exchange Effectiveness and Pressure Drop for Air Flow Through Perforated Plates With and Without Crosswinds
,”
ASME J. Heat Transfer
0022-1481,
116
, pp.
391
399
.
7.
Decker
,
G. W. E.
,
Hollands
,
K. G. T.
, and
Brunger
,
A. P.
, 2001, “
Heat-Exchange Relations for Unglazed Transpired Solar Collectors With Circular Holes on a Square or Triangular Pitch
,”
Sol. Energy
0038-092X,
71
(
1
), pp.
33
45
.
8.
Hollick
,
J. C.
, 1994, “
Solar Cogeneration Panels
,”
Renewable Energy
0960-1481,
15
(
1–4
), pp.
195
200
.
9.
Clarke
,
J. A.
,
Johnstone
,
C.
,
Kelly
,
N.
, and
Strachan
,
P. A.
, 1997, “
The Simulation of Photovoltaic-integrated Building Facades
,”
Building Simulation ’97
,
Prague
, pp.
189
195
.
10.
RETScreen International website: ⟨www.retscreen.netwww.retscreen.net
11.
Millman
,
J.
, and
Grabel
,
A.
, 1987,
Microelectronics
,
McGraw-Hill
,
New York
.
12.
Wolf
,
H. F.
, 1971,
Semiconductors
,
John Wiley and Sons Inc
,
New York
.
13.
Duffie
,
J. A.
, and
Beckman
,
W. A.
, 1991,
Solar Engineering of Thermal Processes
, 2nd ed.,
John Wiley & Sons Inc
,
New York
.
14.
Coventry
,
J. S.
, 2005, “
Performance of a Concentrating Photovoltaic∕Thermal Solar Collector
,”
Sol. Energy
0038-092X,
78
(
2
), pp.
211
222
.
You do not currently have access to this content.