This paper deals with a new model of HVAC systems for hourly simulations. The former is derived from a short time step model that is priory described. The hourly model is appraised by comparing its predictions to those of the short time step simulations. Finally, a sensitivity analysis is carried out to understand the cause of the discrepancies between the two models when it occurs. The analysis also allows to identify the factors that mainly affect the system performance.

1.
O’Neal
,
D. L.
, and
Katipamula
,
S.
,
1993
, “
Development of Nondimensional Cycling Model for Estimating the Seasonal Performance of Air Conditioners
,”
ASME J. Sol. Energy Eng.
,
115
, pp.
176
181
.
2.
McQuistion, F. C. and Parker, J. D., 1988, Heating, Ventilating and Air Conditioning Analysis and Design, John Wiley, New York.
3.
Parken, W. H., Didion, D. A., Wojciechoski, P. H., and Chern, L., 1985, “Field Performance of Three Residential Heat Pumps in the Cooling Mode,” NBSIR 85-3107, report by National Bureau of Standards, Washington D.C.
4.
Henderson, H. I., Parker, D., Huang, Y. J., 2000, “Improving DOE-2’s RESYS Routine: User Defined Functions to Provide More Accurate Part-load Energy Use and Humidity Predictions,” Proceedings of the ACEEE Summer Study on Energy Efficiency in Buildings, Pacific Grove, CA, Aug. 2000. DOE 2 Technical Report LBNL-46304 available at http://gundog.lbl.gov/dirpubs/d2all.html.
5.
O’Nea
,
D. L.
, and
Katipamula
,
S.
,
1991
, “
Performance Degradation During On-Off Cycling of Single-Speed Air Conditioners and Heat Pump: Model Development and Analysis
,”
ASHRAE Trans.
,
97
(
2
), pp.
316
323
.
6.
Mara
,
T. A.
,
Garde
,
F.
,
Boyer
,
H.
, and
Mamode
,
M.
,
2001
, “
Empirical Validation of the Thermal Model of a Passive Solar Test Cell
,”
Energy Build.
,
33
(
6
), pp.
589
599
.
7.
Mara
,
T. A.
,
Boyer
,
H.
, and
Garde
,
F.
,
2002
, “
Parametric Sensitivity Analysis of a Test Cell Thermal Model Using Spectral Analysis
,”
ASME J. Sol. Energy Eng.
,
124
, pp.
237
242
.
8.
Henderson
,
H. I.
, and
Rengarajan
,
K.
,
1996
, “
A Model to Predict the Latent Capacity of Air Conditioners and Heat Pumps at Part-Load Conditions with the Constant Fan Mode
,”
ASHRAE Trans.
,
102
(
1
), pp.
266
274
.
9.
Goldsmith
,
V. W.
,
Hart
,
G. H.
, and
Reiner
,
R. C.
,
1980
, “
A note on the Degradation Coefficient of a Field Tested Heat Pump—Cooling and Heating Mode
,”
ASHRAE Trans.
,
86
(
2
), pp.
368
375
.
10.
Garde
,
F.
,
Mara
,
T. A.
,
Lucas
,
F.
,
Lauret
,
A. P.
,
Bastide
,
A.
,
2002
, “
Development of a Nondimensional Model for Estimating the Cooling Capacity and Electric Consumption of Single-Speed Split Systems Incorporated in a Building Thermal Simulation Program
,”
ASHRAE Trans.
, Annual meeting, Honolulu, ref. HI-02-18-03.
You do not currently have access to this content.