Mass recovery can play an important role to better the performance of adsorption refrigeration cycles. Cooling capacity can be significantly increased with mass recovery process. The coefficient of performance (COP) of the activated carbon/ammonia adsorption refrigeration cycle might be increased or decreased with mass recovery process due to different working conditions. The advantage is that its COP is not sensitive to the variation of heat capacity of adsorber metal and condensing and evaporating temperature. The cycle with mass and heat recovery has a relatively high COP.

1.
Pons
,
M.
,
Meunier
,
F.
, and
Cacciola
,
G.
, et al.
,
1999
, “
Thermodynamic Based Comparison of Sorption Systems for Cooling and Heat Pumping
,”
Int. J. Refrig.
,
22
, pp.
5
17
.
2.
Pons
,
M.
, and
Poyelle
,
F.
,
1999
, “
Adsorptive Machines with Advanced Cycles for Heat Pumping or Cooling Applications
,”
Int. J. Refrig.
,
22
, pp.
27
37
.
3.
Wang
,
R. Z.
,
Wu
,
J. Y.
,
Xu
,
Y. X.
, and
Wang
,
W.
,
2001
, “
Performance Researches and Improvements on Heat Regenerative Adsorption Recovery and Heat Pump
,”
Energy Convers. Manage.
,
42
(
2
), pp.
233
249
.
4.
Wang
,
R. Z.
,
Wu
,
J. Y.
,
Xu
,
Y. X.
,
Teng
,
Y.
, and
Shi
,
W.
,
1998
, “
Experiment on a Continuous Heat Regenerative Adsorption Refrigerator using Spiral Plate Heat Exchanger as Adsorbers
,”
Appl. Therm. Eng.
,
18
, pp.
13
23
.
5.
van Benthem
,
G. H. W.
,
Cacciola
,
G.
, and
Restaccia
,
G.
,
1995
, “
Regenerative Adsorption Heat Pumps: Optimization of the Design
,”
Heat Recovery Syst. CHP
,
15
, pp.
531
544
.
6.
Shelton
,
S. V.
,
Wepfer
,
W. J.
, and
Miles
,
D. J.
,
1990
, “
Ramp Wave Analysis of the Solid/Vapor Heat Pump
,”
ASME J. Energy Resour. Technol.
,
112
, pp.
69
78
.
7.
Critoph
,
R. E.
,
1996
, “
Performance Estimation of Convective Thermal Wave Adsorption Cycles
,”
Appl. Therm. Eng.
,
16
, pp.
429
437
.
8.
Tan
,
Z. C.
, and
Wang
,
R. Z.
,
1998
, “
Research on the Double Effect Cascade Adsorption Refrigeration
,”
Acta Energiae Solaris Sinica (in Chinese)
,
19
, pp.
156
160
.
9.
Turner, L., 1992, “Improvement of Activated Charcoal-Ammonia Adsorption Heat Pumping/Refrigeration Cycles,” Ph.D. thesis, Warwick Univ.
10.
Poyelle F., Guilleminot J. J., Meunier F., and Soide I., 1996, “Experimental Test of a Gas Fired Adsorptive Air Conditioning System,” Proc. Ab-Sorption ’96, Int. Absorption Heat Pump Conf., Montreal, 1, pp. 221–229.
11.
Pons
,
M.
,
1997
, “
Analysis of the Adsorption Cycles with Thermal Recovery Based on the Entropic Mean Temperatures
,”
Appl. Therm. Eng.
,
17
, pp.
615
627
.
12.
Szarzynski
,
S.
,
Feng
,
Y.
, and
Pons
,
M.
,
1997
, “
Study of Different Internal Vapor Transports for Adsorption Cycles with Heat Recovery
,”
Int. J. Refrig.
,
20
, pp.
390
401
.
13.
Teng
,
Y.
,
Wang
,
R. Z.
, and
Wu
,
J. Y.
,
1997
, “
Study of the Fundamentals of Adsorption Systems
,”
Appl. Therm. Eng.
,
17
, pp.
327
338
.
14.
Wang
,
R. Z.
,
2001
, “
Adsorption Refrigeration Research in Shanghai Jiao Tong University
,”
Renewable Energy
,
5
, pp.
1
37
.
You do not currently have access to this content.