An experimental study of an evacuated-tube, integral-collector-storage water heater was conducted in an indoor solar simulator. Useful collected energy, radiation-induced stratification and draw-induced mixing are characterized in eight trials in which test duration, initial tank water temperature, flow rate during withdrawal of heated water from the collector, withdrawal pattern and reflectance of the back-plane were varied. All tests were performed at nominal irradiance of 900 W/m2, normal incidence, and collector slope of 45 degrees. The capability of the TRNSYS integral collector storage model to predict performance for operating conditions for which data are assumed to be unavailable was assessed. Using data from one experimental trial, optical efficiency (τα) of the collector was determined by matching predicted useful energy gain to measured gain. Effectiveness of the calibrated model was based on a comparison of predicted gains to measured values obtained in the remaining seven trials. For five of seven trials, predicted performance is within nine percent of measured performance and less than experimental error. For the other two trials, predicted performance is within 15 percent of measured performance. The higher discrepancies may be partially due to experimental conditions not modeled such as heating of the piping connecting the collector to the test facility and inadequate characterization of back-plane reflectivity. The model does not predict radiation-induced stratification. Although the effect of mixing during draws can be approximated by specifying the number of fully mixed volume segments in the tanks, selection of number of nodes requires knowledge of the behavior of the system. The number of nodes selected has minimal impact on total energy gain, but does affect the temperature of water delivered to the load.

1.
Albrecht, B., Cox, S. K., 1976, “Pyrgeometer Data Reduction and Calibration Procedures,” Atmospheric Science Paper No. 251, Department of Atmospheric Science, Colorado State University, Fort Collins, CO.
2.
American Society of Heating, Refrigerating and Air Conditioning Engineers, 1986, “Methods of Testing to Determine the Thermal Performance of Solar Collectors,” Standard 95-1986, Atlanta, GA.
3.
Burch, J., National Renewable Energy Laboratory, 1993, personal communication.
4.
Davidson
J. H.
,
Carlson
W. T.
, and
Duff
W. S.
,
1992
, “
Impact of Component Selection and Operation on Thermal Ratings of Drain-Back Solar Water Heaters
,”
ASME JOURNAL OF SOLAR ENERGY ENGINEERING
, Vol.
114
, pp.
219
226
.
5.
Duff, W. S., and Menon, A., 1993, “Parametric Design Study of Cylindrical Absorber Tubular Collectors with and Without Reflectors,” Solar’93, Proceedings of the 1993 Annual Conference American Energy Society, pp. 330–336.
6.
Fanney
A. H.
, and
Klein
S. A.
,
1987
, “
Comparison of Experimental and Calculated Performance of Integral Collector-Storage Solar Water Heaters
,”
Solar Energy
, Vol.
38
, No.
5
, pp.
303
309
.
7.
Kenny
S. P.
, and
Davidson
J. H.
,
1994
, “
Design of an Indoor Solar Simulator
,”
ASME JOURNAL OF SOLAR ENERGY ENGINEERING
, Vol.
116
, pp.
200
205
.
8.
Menon, A., 1993, personal communication.
9.
Reichmuth, H., and Robison, D., 1982, “An Analytical Model and Associated Test Procedure for Predicting Performance of Batch Type Solar DHW Systems,” Proceedings of the 1983 ASES Passive Solar Conference, Columbus, OH.
10.
Sherman, C., Wood, B. D., and Mason, J., 1979, “Effect of Vertical Wall Conductance on Temperature Relation in Thermally Stratified Liquid Thermal Storage Tanks,” Sun II. Proceedings of the International Solar Energy Society Silver Jubilee Congress, Atlanta, GA, pp. 591–595.
11.
Solar Rating and Certification Corporation, 1984, “Test Methods and Minimum Standard for Certifying Solar Water Heating Systems,” Standard 200-82, Washington, DC.
12.
Weller, P., Clark, G., and Collins, W., 1985, “Indoor Testing of an Integral Passive Solar Water Heater,” Proceedings of the 10th National Passive Solar Conference, Raleigh, NC, pp. 15–20.
13.
Wells, K. W., and Thomas, W. C., 1987, “Experimental Investigation of Night-time Losses from Integral Collector Storage Solar Water Systems,” Proceedings of the ASME-JSME-JSES Solar Energy Conference, pp. 452–458.
14.
Zollner
A.
,
Klein
S. A.
, and
Beckman
W. A.
,
1985
, “
A Performance Prediction Methodology for Integral Collection-Storage Solar Domestic Hot Water Systems
,”
ASME JOURNAL OF SOLAR ENERGY ENGINEERING
, Vol.
107
, pp.
265
272
.
This content is only available via PDF.
You do not currently have access to this content.