A rotary dehumidifier consists of a rotating porous matrix made of a desiccant with mechanically supporting materials. The dehumidification performance of a rotary dehumidifier wheel depends on its rotational speed, the sorption properties of the desiccant, the heat and mass transfer characteristics of the matrix, and the size of the dehumidifier. The effect of the rotational speed on the dehumidification performance of a rotary dehumidifier has been investigated by Zheng, Worek, and Novosel (1993). This paper extends that previous work and investigates the effects of desiccant sorption properties, the heat and mass transfer characteristics, and the size of the rotary dehumidifier on the dehumidification performance. The results show that the using desiccant materials in a rotary dehumidifier with different adsorption characteristics results in a wide variation in dehumidification performance. However, the maximum performance of a rotary dehumidifier occurs for a desiccant material having an isotherm shape that can be characterized to have a separation factor of 0.07. Also, as the desiccant moisture uptake increases, the dehumidifier performance also increases. However, the performance improvement for a desiccant matrix having a maximum moisture uptake of larger than 0.25 by weight is not significant. The heat and mass transfer properties and the size of a rotary dehumidifier are characterized by the number of transfer units NTU. Generally, the larger the NTU, the better dehumidification performance. However, similar to the maximum moisture uptake, when the NTU is larger than 12, the performance will not improve significantly. Also, the dehumidifier with the most favorable adsorption characteristic has a slowest rotational speed, which results in a lower power requirements to rotate the desiccant wheel and smaller carry-over losses.

1.
Belding, W. A., et al., 1988, “Development of Desiccant Materials for Cooling Systems Applications—Phase I Final Report,” Gas Research Institute Report GRI-88/0343.
2.
Charoensupaya
D.
, and
Worek
W. M.
,
1988
, “
Parametric Study and Optimization of an Open-Cycle Desiccant Cooling System
,”
Energy—The International Journal
, Vol.
13
, No.
9
, pp.
739
747
.
3.
Collier, R. K., Jr., 1988, “Advanced Desiccant Materials Assessment—Phase II,” Gas Research Institute Report GRI-88/0125.
4.
Collier, R. K., Jr., Cale, T. S., and Lavan, Z., 1986, “Advanced Desiccant Materials Assessment,” Gas Research Institute Report GRI-86/0182.
5.
Collier
R. K.
,
Novosel
D.
, and
Worek
W. M.
,
1990
, “
Simulation of Open-Cycle Desiccant Cooling System Performance
,”
ASHRAE Transactions
, Vol.
96
, Pt.
1
, pp.
1262
1268
.
6.
Dini
S.
, and
Worek
W. M.
,
1986
, “
Sorption Equilibrium of a Solid Desiccant Felt and the Effect of Sorption Properties on a Cooled-Bed Desiccant Cooling System
,”
Journal of Heat Recovery Systems
, Vol.
6
, No.
2
, pp.
151
167
.
7.
Ruthven, D. M., 1984, Principles of Adsorption and Adsorption Processes, John Wiley and Sons, New York.
8.
Zheng
W.
, and
Worek
W. M.
,
1993
, “
Numerical Simulation of Combined Heat and Mass Transfer Processes in a Rotary Dehumidifier
,”
Numerical Heat Transfer
, Part A, Vol.
23
, pp.
211
232
.
9.
Zheng
W.
,
Worek
W. M.
, and
Novosel
D.
,
1992
, “
Control and Optimization of Rotational Speeds of Rotary Dehumidifiers
,”
ASHRAE Transactions
, Vol.
99
, Part 1, pp.
825
833
.
This content is only available via PDF.
You do not currently have access to this content.