The transient thermal response of a rock bed with no net fluid flow is examined following all-day charging under clear sky conditions. The experimental system consists of 1.86 m2 (20 ft2) of flat-plate solar collectors using air as the working fluid, a flow control system, and a 0.357 m3 (12.6 ft3) rock bed for thermal energy storage. A thermocline is established in the bed during charging due to the time-varying nature of the collector outlet temperature. Experimental measurements of the temperature distribution in the bed for a 13-hour stagnation period allow a preliminary estimate of the loss of available energy in the storage medium. The net loss in thermodynamic availability is 30 percent. Since the temperatures in the upper regions of the bed are lower than those in the central regions at the end of charging under clear sky conditions, the possibility of natural convection motion of the fluid in the bed exists. An “apparent” local thermal diffusivity is calculated and from comparison with stagnant bed values indicates that natural convection motion may occur in the upper regions of the bed.
Skip Nav Destination
Article navigation
February 1985
Research Papers
Observations on the Decay of a Thermocline in a Rock Bed With No Net Fluid Flow
D. E. Beasley,
D. E. Beasley
Department of Mechanical Engineering, Clemson University, Clemson, S.C. 29631
Search for other works by this author on:
J. A. Clark,
J. A. Clark
Department of Mechanical Engineering and Applied Mechanics, University of Michigan, Ann Arbor, Mich. 48109
Search for other works by this author on:
M. J. Holstege
M. J. Holstege
Department of Mechanical Engineering and Applied Mechanics, University of Michigan, Ann Arbor, Mich. 48109
Search for other works by this author on:
D. E. Beasley
Department of Mechanical Engineering, Clemson University, Clemson, S.C. 29631
J. A. Clark
Department of Mechanical Engineering and Applied Mechanics, University of Michigan, Ann Arbor, Mich. 48109
M. J. Holstege
Department of Mechanical Engineering and Applied Mechanics, University of Michigan, Ann Arbor, Mich. 48109
J. Sol. Energy Eng. Feb 1985, 107(1): 50-53 (4 pages)
Published Online: February 1, 1985
Article history
Received:
March 1, 1984
Online:
November 11, 2009
Citation
Beasley, D. E., Clark, J. A., and Holstege, M. J. (February 1, 1985). "Observations on the Decay of a Thermocline in a Rock Bed With No Net Fluid Flow." ASME. J. Sol. Energy Eng. February 1985; 107(1): 50–53. https://doi.org/10.1115/1.3267653
Download citation file:
Get Email Alerts
Cited By
Techno-Economic Analysis of Using Reversible Turbomachinery for Pumped Thermal Energy Storage Systems
J. Sol. Energy Eng (October 2024)
Effects of an Annular Baffle on Heat Transfer to an Immersed Coil Heat Exchanger in Thermally Stratified Tanks
J. Sol. Energy Eng (October 2024)
Related Articles
Exergy Analysis and Sustainability Assessment of a Solar-Ground Based Heat Pump With Thermal Energy Storage
J. Sol. Energy Eng (February,2011)
Transient Natural Convection Heat Transfer Correlations for Tube Bundles Immersed in a Thermal Storage
J. Sol. Energy Eng (May,2007)
Numerical and Experimental Investigation on a Combined Sensible and Latent Heat Storage Unit Integrated With Solar Water Heating System
J. Sol. Energy Eng (November,2009)
Thermal Characterization of Prototypical Integral Collector Storage Systems With Immersed Heat Exchangers
J. Sol. Energy Eng (February,2005)
Related Proceedings Papers
Related Chapters
Finite Element Solution of Natural Convection Flow of a Nanofluid along a Vertical Flat Plate with Streamwise Sinusoidal Surface Temperature
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)
Numerical Analysis of a Latent Heat Storage Heat Exchanger Considering the Effect of Natural Convection
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach