Experiments with scala-tympani (ST) phantoms are used to evaluate new electrode arrays and cochlear-implant insertion techniques. To date, phantoms have not accounted for clinical orientations and geometric differences between round-window (RW) insertions and anteroinferior cochleostomy insertions. For improved assessments of insertion experiments, we present a scala-tympani phantom that offers three distinct benefits over previous phantoms: it mimics the standard otologic position, it accommodates for both round-window and anteroinferior cochleostomy insertions, and it incorporates a visual coordinate system based on industry consensus making standardized angular measurements possible.

References

1.
Clark
,
J. R.
,
Warren
,
F. M.
, and
Abbott
,
J. J.
,
2011
, “
A Scalable Model for Human Scala-Tympani Phantoms
,”
ASME J. Med. Dev.
,
5
(
1
), p.
014501
.10.1115/1.4002932
2.
Clark
,
J. R.
,
Leon
,
L.
,
Warren
,
F. M.
, and
Abbott
,
J. J.
,
2012
, “
Magnetic Guidance of Cochlear Implants: Proof-of-Concept and Initial Feasibility Study
,”
ASME J. Med. Dev.
,
6
(
3
), p.
035002
.10.1115/1.4007099
3.
Zhang
,
J.
,
Wei
,
W.
,
Ding
,
J.
,
Roland
,
J. T.
, Jr.
,
Manolidis
,
S.
, and
Simaan
,
N.
,
2010
, “
Inroads Toward Robot-Assisted Cochlear Implant Surgery Using Steerable Electrode Arrays
,”
Otol. Neurotol.
,
31
(
8
), pp.
1199
1206
.10.1097/MAO.0b013e3181e7117e
4.
Majdani
,
O.
,
Schurzig
,
D.
,
Hussong
,
A.
,
Rau
,
T.
,
Wittkopf
,
J.
,
Lenarz
,
T.
, and
Labadie
,
R. F.
,
2010
, “
Force Measurement of Insertion of Cochlear Implant Electrode Arrays In Vitro: Comparison of Surgeon to Automated Insertion Tool
,”
Acta Otolaryngol.
,
130
(
1
), pp.
31
36
.10.3109/00016480902998281
5.
Verbist
,
B. M.
,
Joemai
,
R. M. S.
,
Teeuwisse
,
W. M.
,
Veldkamp
,
W. J. H.
,
Geleijns
,
J.
, and
Frijns
,
J. H. M.
,
2008
, “
Evaluation of 4 Multisection CT Systems in Postoperative Imaging of a Cochlear Implant: A Human Cadaver and Phantom Study
,”
Am. J. Neuroradiol.
,
29
(
7
), pp.
1382
1388
.10.3174/ajnr.A1108
6.
Todd
,
C. A.
,
Naghdy
,
F.
, and
Svehla
,
M. J.
,
2007
, “
Force Application During Cochlear Implant Insertion: An Analysis for Improvement of Surgeon Technique
,”
IEEE Trans. Biomed. Eng.
,
54
(
7
), pp.
1247
1255
.10.1109/TBME.2007.891937
7.
Rebscher
,
S. J.
,
Talbot
,
N.
,
Bruszewski
,
W.
,
Heilmann
,
M.
,
Brasell
,
J.
, and
Merzenich
,
M. M.
,
1996
, “
A Transparent Model of the Human Scala Tympani Cavity
,”
J. Neurosci. Methods
,
64
(
1
), pp.
105
114
.10.1016/0165-0270(95)00116-6
8.
Rebscher
,
S. J.
,
Hetherington
,
A.
,
Bonham
,
B.
,
Wardrop
,
P.
,
Whinney
,
D.
, and
Leake
,
P. A.
,
2008
, “
Considerations for Design of Future Cochlear Implant Electrode Arrays: Electrode Array Stiffness, Size, and Depth of Insertion
,”
J. Rehabil. Res. Dev.
,
45
(
5
), pp.
731
747
.10.1682/JRRD.2007.08.0119
9.
Verbist
,
B. M.
,
Skinner
,
M. W.
,
Cohen
,
L. T.
,
Leake
,
P. A.
,
James
,
C.
,
Boëx
,
C.
,
Holden
,
T. A.
,
Finley
,
C. C.
,
Roland
,
P. S.
,
Roland
,
J. T.
, Jr.
,
Haller
,
M.
,
Patrick
,
J. F.
,
Jolly
,
C. N.
,
Faltys
,
M. A.
,
Briaire
,
J. J.
, and
Frijns
,
J. H. M.
,
2010
, “
Consensus Panel on a Cochlear Coordinate System Applicable in Histologic, Physiologic, and Radiologic Studies of the Human Cochlea
,”
Otol. Neurotol.
,
31
(
5
), pp.
722
730
.10.1097/MAO.0b013e3181d279e0
10.
Marsh
,
M. A.
,
Xu
,
J.
,
Blamey
,
P. J.
,
Whitford
,
L. A.
,
Xu
,
S. A.
,
Silverman
,
J. M.
, and
Clark
,
G. M.
,
1993
, “
Radiologic Evaluation of Multichannel Intracochlear Implant Insertion Depth
,”
Am. J. Otol.
,
14
(
4
), pp.
386
391
.
11.
Cohen
,
L. T.
,
Xu
,
J.
,
Xu
,
S. A.
, and
Clark
,
G. M.
,
1996
, “
Improved and Simplified Methods for Specifying Positions of the Electrode Bands of a Cochlear Implant Array
,”
Am. J. Otol.
,
17
(
6
), pp.
859
865
.
12.
Xu
,
J.
,
Xu
,
S. A.
,
Cohen
,
L. T.
, and
Clark
,
G. M.
,
2000
, “
Cochlear View: Postoperative Radiography for Cochlear Implantation
,”
Am. J. Otol.
,
21
(
1
), pp.
49
56
.10.1016/S0196-0709(00)80112-X
13.
Skinner
,
M. W.
,
Holden
,
T. A.
,
Whiting
,
B. R.
,
Voie
,
A. H.
,
Brunsden
,
B.
,
Neely
,
J. G.
,
Saxon
,
E. A.
,
Hullar
,
T. E.
, and
Finley
,
C. C.
,
2007
, “
In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea
,”
Ann. Otol. Rhinol. Laryngol. Suppl.
,
116
(
4
), pp.
2
24
.
14.
Verbist
,
B. M.
,
Joemai
,
R. M.
,
Briaire
,
J. J.
,
Teeuwisse
,
W. M.
,
Veldkamp
,
W. J.
, and
Frijns
,
J. H.
,
2010
, “
Cochlear Coordinates in Regard to Cochlear Implantation: A Clinically Individually Applicable 3 Dimensional CT-Based Method
,”
Otol. Neurotol.
,
31
(
5
), pp.
738
744
.10.1097/MAO.0b013e3181d8d3c4
15.
Wang
,
H.
,
Northrop
,
C.
,
Burgess
,
B.
,
Liberman
,
M. C.
, and
Merchant
,
S. N.
,
2006
, “
Three-Dimensional Virtual Model of the Human Temporal Bone: A Stand-Alone, Downloadable Teaching Tool
,”
Otol. Neurotol.
,
27
(
4
), pp.
452
457
.10.1097/00129492-200606000-00004
16.
Roland
,
P. S.
,
Wright
,
C. G.
, and
Isaacson
,
B.
,
2007
, “
Cochlear Implant Electrode Insertion: The Round Window Revisited
,”
Laryngoscope
,
117
(
8
), pp.
1397
1402
.10.1097/MLG.0b013e318064e891
17.
Lenarz
,
T.
,
Stover
,
T.
,
Buechner
,
A.
,
Paasche
,
G.
,
Briggs
,
R.
,
Risi
,
F.
,
Pesch
,
J.
, and
Battmer
,
R.-D.
,
2006
, “
Temporal Bone Results and Hearing Preservation With a New Straight Electrode
,”
Audiol. Neurotol.
,
11
(Suppl.
1
), pp.
34
41
.10.1159/000095612
18.
Briggs
,
R. J. S.
,
Tykocinski
,
M.
,
Stidham
,
K.
, and
Roberson
,
J. B.
,
2005
, “
Cochleostomy Site: Implications for Electrode Placement and Hearing Preservation
,”
Acta Otolaryngol.
,
125
(
8
), pp.
870
876
.10.1080/00016480510031489
19.
Nomura
,
Y.
,
1984
, “
Otological Significance of the Round Window
,”
Adv. Otorhinolaryngol.
,
33
, pp.
1
162
.
20.
Erixon
,
E.
,
Högstorp
,
H.
,
Wadin
,
K.
, and
Rask-Andersen
,
H.
,
2009
, “
Variational Anatomy of the Human Cochlea: Implications for Cochlear Implantation
,”
Otol. Neurotol.
,
30
(
1
), pp.
14
22
.10.1097/MAO.0b013e31818a08e8
21.
Wysocki
,
J.
,
1999
, “
Dimensions of the Human Vestibular and Tympanic Scalae
,”
Hear. Res.
,
135
(
1–2
), pp.
39
46
.10.1016/S0378-5955(99)00088-X
22.
Zarowski
,
A.
,
Offeciers
,
E.
,
Postnov
,
A.
,
Vanpoucke
,
F.
, and
Peeters
,
S.
,
2008
, “
Micro-CT Anatomical Measurements in the Human Cochlea
,” Auditory Research Bulletin 2007 Biennial Edition, Advanced Bionics LLC, Valencia, CA.
23.
Biedron
,
S.
,
Prescher
,
A.
,
Ilgner
,
J.
, and
Westhofen
,
M.
,
2010
, “
The Internal Dimensions of the Cochlear Scalae With Special Reference to Cochlear Electrode Insertion Trauma
,”
Otol. Neurotol.
,
31
(
5
), pp.
731
737
.10.1097/MAO.0b013e3181d27b5e
24.
Zrunek
,
M.
,
Lischka
,
M.
,
Hochmair-Desoyer
,
I.
, and
Burian
,
K.
,
1980
, “
Dimensions of the Scala Tympani in Relation to the Diameters of Multichannel Electrodes
,”
Eur. Arch. Otorhinolaryngol.
,
229
(
3–4
), pp.
159
165
.10.1007/BF02565517
25.
Lim
,
Y. S.
,
Park
,
S.-I.
,
Kim
,
Y. H.
,
Oh
,
S. H.
, and
Kim
,
S. J.
,
2005
, “
Three-Dimensional Analysis of Electrode Behavior in a Human Cochlear Model
,”
Med. Eng. Phys.
,
27
(
8
), pp.
695
703
.10.1016/j.medengphy.2004.12.009
26.
Li
,
P. M. M. C.
,
Wang
,
H.
,
Northrop
,
C.
,
Merchant
,
S. N.
, and
Nadol
,
J. B.
, Jr.
,
2007
, “
Anatomy of the Round Window and Hook Region of the Cochlea With Implications for Cochlear Implantation and Other Endocochlear Surgical Procedures
,”
Otol. Neurotol.
,
28
(
5
), pp.
641
648
.10.1097/mao.0b013e3180577949
27.
Kawano
,
A.
,
Seldon
,
H. L.
, and
Clark
,
G. M.
,
1996
, “
Computer-Aided Three-Dimensional Reconstruction in Human Cochlear Maps: Measurement of the Lengths of Organ of Corti, Outer Wall, Inner Wall, and Rosenthal's Canal
,”
Ann. Otol. Rhinol. Laryngol.
,
105
(
9
), pp.
701
709
.
28.
Yoo
,
S. K.
,
Wang
,
G.
,
Rubinstein
,
J. T.
,
Skinner
,
M. W.
, and
Vannier
,
M. W.
,
2000
, “
Three-Dimensional Modeling and Visualization of the Cochlea on the Internet
,”
IEEE Trans. Inf. Technol. Biomed.
,
4
(
2
), pp.
144
151
.10.1109/4233.845207
29.
O'Connor
,
E. F.
, and
Fitzgerald
,
A.
,
2010
, “
Hearing Preservation Surgery: Current Opinions
,”
Adv. Otorhinolaryngol.
,
67
, pp.
108
115
.10.1159/000262602
30.
Czerny
,
C.
,
Steiner
,
E.
,
Gstoettner
,
W.
,
Baumgartner
,
W. D.
, and
Imhof
,
H.
,
1997
, “
Postoperative Radiographic Assessment of the Combi 40 Cochlear Implant
,”
Am. J. Roentgenol.
,
169
(
6
), pp.
1689
1694
.10.2214/ajr.169.6.9393191
31.
Adunka
,
O. F.
, and
Buchman
,
C. A.
,
2007
, “
Scala Tympani Cochleostomy I: Results of a Survey
,”
Laryngoscope
,
117
(
12
), pp.
2187
2194
.10.1097/MLG.0b013e3181453a6c
32.
Wardrop
,
P.
,
Whinney
,
D.
,
Rebscher
,
S. J.
,
Luxford
,
W.
, and
Leake
,
P.
,
2005
, “
A Temporal Bone Study of Insertion Trauma and Intracochlear Position of Cochlear Implant Electrodes. II: Comparison of Spiral Clarion and HiFocus II Electrodes
,”
Hear. Res.
,
203
(
1–2
), pp.
68
79
.10.1016/j.heares.2004.11.007
33.
Boyd
,
P. J.
,
2011
, “
Potential Benefits From Deeply Inserted Cochlear Implant Electrodes
,”
Ear Hear.
,
32
(
4
), pp.
411
427
.10.1097/AUD.0b013e3182064bda
34.
Majdani
,
O.
,
Rau
,
T. S.
,
Baron
,
S.
,
Eilers
,
H.
,
Baier
,
C.
,
Heimann
,
B.
,
Ortmaier
,
T.
,
Bartling
,
S.
,
Lenarz
,
T.
, and
Leinung
,
M.
,
2009
, “
A Robot-Guided Minimally Invasive Approach for Cochlear Implant Surgery: Preliminary Results of a Temporal Bone Study
,”
Int. J. Comput. Assist. Radiol. Surg.
,
4
(
5
), pp.
475
486
.10.1007/s11548-009-0360-8
35.
Su
,
W.-Y.
,
Marion
,
M. S.
,
Hinojosa
,
R.
, and
Matz
,
G. J.
,
1982
, “
Anatomical Measurements of the Cochlear Aqueduct, Round Window Membrane, Round Window Niche, and Facial Recess
,”
Laryngoscope
,
92
(
5
), pp.
483
486
.10.1288/00005537-198205000-00003
You do not currently have access to this content.