Abstract

Postpartum hemorrhage (PPH) is the leading cause of maternal mortality worldwide, and effective interventions for addressing PPH are urgently needed. Uterine balloon tamponade (UBT) is a technique to control PPH. Commercially available UBT devices are expensive and frequently require imaging technology to ensure placement. Condom-catheter uterine tamponade (C-UBT) is a technique appropriate for low-resource settings. Testing of the C-UBT is needed to better understand and optimize this technique for use in a variety of clinical settings including low-resource contexts. We describe here the design, development, and bench-top validation of a reusable C-UBT device optimized for low-resource settings. The device was tested in three differently sized uterine models using a variety of condom balloon configurations. Intrauterine wall pressure application was measured to evaluate the device capacity to apply pressure of at least 90 mmHg, estimating the mean arterial pressure within the uterine vasculature. Bench-top experimental validation of pressure exerted in uterine models demonstrated the device's capability of reaching hemostatic pressure in uterine volumes ranging from 170 to 1740 mL. Device adaptability and versatility were shown through its ability to reach the target pressure of 90 mmHg in different uterine sizes by varying balloon parameters, including condom thickness and condom configuration. The results of this study show the potential of a low-cost, reusable C-UBT device optimized to treat PPH in a variety of clinical settings, including low-resource contexts.

References

1.
Ngwenya
,
S.
,
2016
, “
Postpartum Hemorrhage: Incidence, Risk Factors, and Outcomes in a Low-Resource Setting
,”
Int. J. Womens Health
,
8
, pp.
647
650
.10.2147/IJWH.S119232
2.
Weeks
,
A.
,
2015
, “
The Prevention and Treatment of Postpartum Haemorrhage: What Do We Know, and Where Do We Go To Next?
,”
BJOG
,
122
(
2
), pp.
202
212
.10.1111/1471-0528.13098
3.
Haeri
,
S.
, and
Dildy
,
G. A.
, III
,
2012
, “
Maternal Mortality From Hemorrhage
,”
Semin. Perinatol.
,
36
, pp.
48
55
.10.1053/j.semperi.2011.09.010
4.
Shah
,
M.
, and
Wright
,
J. D.
,
2009
, “
Surgical Intervention in the Management of Postpartum Hemorrhage
,”
Semin. Perinatol.
,
33
(
2
), pp.
109
115
.10.1053/j.semperi.2008.12.006
5.
World Health Organization
2012
,
WHO Recommendations for the Prevention and Treatment of Postpartum Haemorrhage
,
World Health Organization
,
Geneva
.
6.
Maternal and Neonatal Directed Assessment of Technology,
2014
, “
Devices to Control Hemorrhage
,”
Research Triangle Institute International
, Research Triangle Park, NC, accessed Aug. 15, 2019, http://mnhtech.org/technology/technology-briefs/devices-to-control-hemorrhage/
7.
Cook Medical, 2019, “
Bakri Postpartum Balloon With Rapid Instillation Components
,”
Cook Medical
, Bloomington, IN, accessed Aug. 15, 2019, https://www.cookmedical.com/products/wh_sosr_webds/
8.
Gronvall
,
M.
,
Tikkanen
,
M.
,
Tallberg
,
E.
,
Paavonen
,
J.
, and
Stefanovic
,
V.
,
2013
, “
Use of Bakri Balloon Tamponade in the Treatment of Postpartum Hemorrhage: A Series of 50 Cases From a Tertiary Teaching Hospital
,”
Acta. Obstet. Gynecol. Scand.
,
92
(
40
), pp.
433
438
.10.1111/j.1600-0412.2012.01531.x
9.
Georgiou
,
C.
,
2014
, “
A Review of Current Practice in Using Balloon Tamponade Technology in the Management of Postpartum Haemorrhage
,”
Hypertens. Res. Pregnancy.
,
2
(
1
), pp.
1
10
.10.14390/jsshp.2.1
10.
Cho
,
Y.
,
Rizvi
,
C.
,
Uppal
,
T.
, and
Condous
,
G.
,
2008
, “
Ultrasonographic Visualization of Balloon Placement for Uterine Tamponade in Massive Primary Postpartum Hemorrhage
,”
Ultrasound Obstet. Gynecol.
,
32
(
5
), pp.
711
713
.10.1002/uog.5408
11.
Thapa
,
K.
,
Malla
,
B.
,
Pandey
,
S.
, and
Amatyza
,
S.
,
2010
, “
Intrauterine Condom Tamponade in Management of Post Partum Haemorrhage
,”
J. Nepal. Health Res. Counc.
,
8
(
1
), pp.
19
22
.https://www.ncbi.nlm.nih.gov/pubmed/21879008
12.
Maya
,
E. T.
,
Buntugu
,
K. A.
,
Aki
,
L.
, and
Srofenyoh
,
E. K.
,
2015
, “
Condom Tamponade in the Management of Primary Postpartum Haemorrhage: A Report of Three Cases in Ghana
,”
Afr. J. Reprod. Health.
,
19
(
3
), pp.
151
157
. https://www.ncbi.nlm.nih.gov/pubmed/26897924
13.
Kandeel
,
M.
,
Sanad
,
Z.
,
Ellakwa
,
H.
,
El Halaby
,
A.
,
Rezk
,
M.
, and
Saif
,
I.
,
2016
, “
Management of Postpartum Hemorrhage With Intrauterine Balloon Tamponade Using a Condom Catheter in an Egyptian Setting
,”
Int. J. Gynaecol. Obstet.
,
135
(
3
), pp.
272
275
.10.1016/j.ijgo.2016.06.018
14.
Doumouchtsis
,
S. K.
,
Papageorghiou
,
A. T.
,
Vernier
,
C.
, and
Arulkumaran
,
S.
,
2008
, “
Management of Postpartum Hemorrhage by Uterine Balloon Tamponade: Prospective Evaluation of Effectiveness
,”
Acta Obstet. Gynecol. Scand.
,
87
(
8
), pp.
849
855
.10.1080/00016340802179822
15.
Santhanam
,
R.
,
Viswanathan
,
R. M.
, and
Priya
, V.
,
2018
, “
Condom Tamponade in the Management of Atonic Postpartum Hemorrhage
,”
Int. J. Reprod. Contracept. Obstet. Gynecol.
,
7
(
6
), pp.
2276
2282
.10.18203/2320-1770.ijrcog20182335
16.
Wright
,
C. E.
,
Chauhan
,
S. P.
, and
Abuhamad
,
A. Z.
,
2014
, “
Bakri Balloon in the Management of Postpartum Hemorrhage: A Review
,”
Am. J. Perinatol.
,
31
(
11
), pp.
957
964
.10.1055/s-0034-1372422
17.
Mishra
,
N.
,
Shrivastava
,
C.
,
Agrawal
,
S.
,
Mahilange
,
A.
,
Sai
,
M. M.
, and
Gulabani
,
K.
,
2017
, “
Easy Balloon: The Easiest to Assemble Condom Balloon Uterine Tamponade for Primary Level of Health Care Centres
,”
J. Obstet. Gynecol. India
,
67
(
5
), pp.
378
381
.10.1007/s13224-017-1014-3
18.
Condous
,
G. S.
,
Arulkumaran
,
S.
,
Symonds
,
I.
,
Chapman
,
R.
,
Sinha
,
A.
, and
Razvi
,
K.
,
2003
, “
The “Tamponade Test” in the Management of Massive Postpartum Hemorrhage
,”
Obstet. Gynecol.
,
101
(
4
), pp.
767
772
.10.1097/00006250-200304000-00026
19.
Lawrie
,
T. A.
,
Rogozinska
,
E.
,
Sobiesuo
,
P.
,
Vogel
,
J. P.
,
Ternent
,
L.
, and
Oladapo
,
O. T.
,
2019
, “
A Systematic Review of the Cost-Effectiveness of Uterotonic Agents for the Prevention of Postpartum Hemorrhage
,”
Int. J. Gynecol. Obstet.
,
146
(
1
), pp.
56
64
. 10.1002/ijgo.12836
20.
McQuivey
,
R. W.
,
Block
,
J. E.
, and
Massaro
,
R. A.
,
2018
, “
Ebb® Complete Tamponade System: Effective Hemostasis for Postpartum Hemorrhage
,”
Med. Dev. (Auckl)
,
11
, pp.
57
63
.10.2147/MDER.S158944
21.
eSutures.com, 2019, “
Clinical Innovations Ebb Complete Tamponade System—Postpartum Hemorrhage Balloon
,” CTS-1000-SD, Mokena, IL, accessed Aug. 15, 2019, https://www.esutures.com/product/3-short-dated/3-miscellaneous/1191-clinical-innovations/46312922-clinical-innovations-ebb-complete-tamponade-system--postpartum-hemorrhage-balloon-CTS-1000-SD/
22.
Massachusetts General Hospital, “
Every Second Matters for Mothers and Babies—Uterine Balloon Tamponade for Postpartum Hemorrhage
,” The General Hospital Corporation, Boston, MA, accessed Aug. 15, 2019, https://www.massgeneral.org/emergency-medicine/global-health/initiatives-and-programs/every-second-matters-for-mothers-and-babies-uterine-balloon-tamponade-for-postpartum-hemorrhage
23.
Tamizian
,
O.
, and
Arulkumaran
,
S.
,
2001
, “
The Surgical Management of Postpartum Haemorrhage
,”
Curr. Opin. Obstet. Gynecol.
,
13
(
2
), pp.
127
131
.10.1097/00001703-200104000-00005
24.
Aderoba
,
A. K.
,
Olagbuji
,
B. N.
,
Akintan
,
A. L.
,
Oyeneyin
,
O. L.
,
Owa
,
O. O.
, and
Osaikhuwuomwan
,
J. A.
,
2017
, “
Condom-Catheter Tamponade for the Treatment of Postpartum Haemorrhage and Factors Associated With Success: A Prospective Observational Study
,”
BJOG
,
124
(
11
), pp.
1764
1771
.10.1111/1471-0528.14361
25.
Tindell
,
K.
,
Garfinkel
,
R.
,
Abu-Haydar
,
E.
,
Ahn
,
R.
,
Burke
,
T. F.
,
Conn
,
K.
, and
Eckardt
,
M.
,
2013
, “
Uterine Balloon Tamponade for the Treatment of Postpartum Haemorrhage in Resource-Poor Settings: A Systematic Review
,”
BJOG
,
120
(
1
), pp.
5
14
.10.1111/j.1471-0528.2012.03454.x
26.
Goergiou
,
C.
,
2010
, “
Intraluminal Pressure Readings During the Establishment of a Positive ‘Tamponade Test’ in the Management of Postpartum Haemorrhage
,”
BJOG
,
117
(
3
), pp.
295
202
.10.1111/j.1471-0528.2009.02436.x
27.
Nathan
,
H. L.
,
Cottam
,
K.
,
Hezelgrave
,
N. L.
,
Seed
,
P. T.
,
Briley
,
A.
,
Bewley
,
S.
,
Chappell
,
L. C.
, and
Shennan
,
A. H.
,
2016
, “
Determination of Normal Ranges of Shock Index and Other Haemodynamic Variables in the Immediate Postpartum Period: A Cohort Study
,”
PLoS One
,
11
(
12
), p.
e0168535
.10.1371/journal.pone.0168535
28.
Wachsberg
,
R. H.
,
Kurtz
,
A. B.
,
Levine
,
C. D.
,
Solomon
,
P.
, and
Wapner
,
R. J.
,
1994
, “
Real-Time Ultrasonographic Analysis of the Normal Postpartum Uterus: Technique, Variability, and Measurements
,”
J. Ultrasound Med.
,
13
(
3
), pp.
215
221
.10.7863/jum.1994.13.3.215
29.
Mulic-Lutvica
,
A.
,
Bekuretsion
,
M.
,
Bakos
,
O.
, and
Axelsson
,
O.
,
2001
, “
Ultrasonic Evaluation of the Uterus and Uterine Cavity After Normal, Vaginal Delivery
,”
Ultrasound Obstet. Gynecol.
,
18
(
5
), pp.
491
498
.10.1046/j.0960-7692.2001.00561.x
30.
Chan
,
C.
,
Razvi
,
K.
,
Tham
,
K. F.
, and
Arulkumaran
,
S.
,
1997
, “
The Use of a Sengstaken—Blakemore Tube to Control Post-Partum Haemorrhage
,”
Int. J. Gynaecol. Obstet.
,
58
(
2
), pp.
251
252
.10.1016/S0020-7292(97)00090-8
31.
Keriakos
,
R.
, and
Mukhopadhyay
,
A.
,
2006
, “
The Use of the Rusch Balloon for Management of Severe Postpartum Haemorrhage
,”
J. Obstet. Gynaecol.
,
26
(
4
), pp.
335
338
.10.1080/01443610600595077
32.
Lyon
,
D. S.
,
2004
, “
Postpartum Care
,”
Gynecology and Obstetrics
, Vol.
2
,
J. J.
Sciarra
, ed.,
Lippincott Williams & Wilkins
,
Philadelphia, PA
, p.
90
.
33.
Georgiou
,
C.
,
2009
, “
Balloon Tamponade in the Management of Postpartum Haemorrhage: A Review
,”
BJOG
,
116
(
6
), pp.
748
757
.10.1111/j.1471-0528.2009.02113.x
34.
Mvundura
,
M.
,
Kokonya
,
D.
,
Abu-Haydar
,
E.
,
Okoth
,
E.
,
Herrick
,
T.
,
Mukabi
,
J.
,
Carlson
,
L.
,
Oguttu
,
M.
, and
Burke
,
T.
,
2017
, “
Cost-Effectiveness of Condom Uterine Balloon Tamponade to Control Severe Postpartum Hemorrhage in Kenya
,”
Int. J. Gynaecol. Obstet.
,
137
(
2
), pp.
185
191
.10.1002/ijgo.12125
35.
Sweat
,
M.
,
Denison
,
J.
,
Kennedy
,
C.
,
Tedrow
,
V.
, and
O'Reilly
,
K.
,
2012
, “
Effects of Condom Social Marketing on Condom Use in Developing Countries: A Systematic Review and Meta-Analysis, 1990–2010
,”
Bull. World Health Organ.
,
90
(
8
), pp.
613A
622A
.10.2471/BLT.11.094268
36.
Solidworks,
2016
,
Dassault Systèmes
,
Vélizy-Villacoublay
,
France
.
37.
MATLAB
,
2017
, “
The Mathworks
,” The Mathworks,
Natick, MA
.
38.
Shomali
,
M.
,
Opie
,
D.
,
Avasthi
,
T.
, and
Trilling
,
A.
,
2015
, “
Nitrogen Dioxide Sterilization in Low-Resource Environments: A Feasibility Study
,”
PLoS One
,
10
(
6
), p.
e0130043
.10.1371/journal.pone.0130043
You do not currently have access to this content.