Skin cancer represents one of the most common forms of cancer in the U.S. This and other skin disorders can be effectively diagnosed by performing a punch biopsy to obtain full-thickness skin specimens. Their quality depends on the forces exerted by the punch cannula during the cutting process. The reduction of these forces is critical in the extraction of high quality tissue samples from the patient. During skin biopsy, the biopsy punch (BP) is advanced into the lesion while it is rotated alternately clockwise and counterclockwise generating, therefore, a rotary vibrational motion. No previous studies analyzed whether this motion is effective in soft tissue cutting and if it could be improved. In this study, the BP procedure is investigated in detail. First, the steady cutting motion of the BP is analyzed. Then, the superimposition of several vibrational motions onto the rotary motion of the BP is investigated. Analytical models, based on a fracture mechanics approach, are adopted to predict the cutting forces. Experimental studies are performed on phantom tissue, usually adopted in medical investigations. The results demonstrate that the application of rotary vibrational motions determines the increase of the force and penetration depth necessary to fracture soft tissue, while the implementation of axial vibrations can lead to 30% decrease of the axial force. The outcome of this study can benefit several clinical procedures in which a cannula device is used to cut and collect soft tissue samples.

References

1.
Zuber
,
T. J.
,
2002
, “
Punch Biopsy of the Skin
,”
Am. Fam. Phys.
,
65
(
6
), pp.
1155
1158
.https://www.ncbi.nlm.nih.gov/pubmed/11925094
2.
Linos
,
E.
,
Katz
,
K. A.
, and
Colditz
,
G. A.
,
2016
, “
Skin Cancer—The Importance of Prevention
,”
JAMA Intern. Med.
,
176
(
10
), pp.
1435
1436
.
3.
Izumi
,
H.
,
Yajima
,
T.
,
Aoyagi
,
S.
,
Tagawa
,
N.
,
Arai
,
Y.
, and
Hirata
,
M.
,
2008
, “
Combined Harpoonlike Jagged Microneedles Imitating Mosquito's Proboscis and Its Insertion Experiment With Vibration
,”
IEEJ Trans. Electr. Electron. Eng.
,
3
(
4
), pp.
425
431
.
4.
Kong
,
X. Q.
, and
Wu
,
C. W.
,
2009
, “
Measurement and Prediction of Insertion Force for the Mosquito Fascicle Penetrating Into Human Skin
,”
J. Bionic Eng.
,
6
(
2
), pp.
143
152
.
5.
Aoyagi
,
S.
,
Takaoki
,
Y.
,
Takayanagi
,
H.
,
Huang
,
C.
,
Tanaka
,
T.
,
Suzuki
,
M.
,
Takahashi
,
T.
,
Kanzaki
,
T.
, and
Matsumoto
,
T.
,
2012
, “
Equivalent Negative Stiffness Mechanism Using Three Bundled Needles Inspired by Mosquito for Achieving Easy Insertion
,”
IEEE/RSJ
International Conference on Intelligent Robots and Systems
,
Vilamoura
,
Portugal
, Oct. 7–12, pp.
2295
2300
.
6.
Barnett
,
A. C.
,
Feidner
,
M.
, and
Moore
,
J. Z.
,
2015
, “
Vibration Needle Tissue Cutting With Varying Tip Geometry
,”
ASME
Paper No. MSEC2015-9353.
7.
Begg
,
N. D.
, and
Slocum
,
A. H.
,
2014
, “
Audible Frequency Vibration of Puncture-Access Medical Devices
,”
Med. Eng. Phys.
,
36
(
3
), pp.
371
377
.
8.
Giovannini
,
M.
,
Ren
,
H.
,
Wang
,
X.
, and
Ehmann
,
K.
,
2017
, “
Tissue Cutting With Microserrated Biopsy Punches
,”
ASME J. Micro Nano-Manuf.
,
5
(
4
), p.
041004
.
9.
Han
,
P.
, and
Ehmann
,
K. F.
,
2013
, “
Study of the Effect of Cannula Rotation on Tissue Cutting for Needle Biopsy
,”
Med. Eng. Phys.
,
35
(
11
), pp.
1584
1590
.
10.
Badaan
,
S.
,
Petrisor
,
D.
,
Kim
,
C.
,
Mozer
,
P.
,
Mazilu
,
D.
,
Gruionu
,
L.
,
Patriciu
,
A.
,
Kevin
,
C.
, and
Stoianovici
,
D.
,
2011
, “
Does Needle Rotation Improve Lesion Targeting?
,”
Int. J. Med. Rob. Comput. Assist. Surg.
,
7
(
2
), pp.
138
147
.
11.
Atkins
,
A. G.
,
Xu
,
X.
, and
Jeronimidis
,
G.
,
2004
, “
Cutting by 'Pressing and Slicing' of Thin Floppy Slices of Materials Illustrated by Experiments on Cheddar Cheese and Salami
,”
J. Mater. Sci.
,
39
(
8
), pp.
2761
2766
.
12.
Slocum
,
A.
,
1992
,
Precision Machine Design
,
Society of Manufacturing Engineers
,
Prentice Hall
,
Englewood Cliffs, NJ
.
13.
Podder
,
T. K.
,
Clark
,
D. P.
,
Sherman
,
J.
,
Fuller
,
D.
,
Messing
,
E. M.
,
Rubens
,
D. J.
,
Strang
,
J. G.
,
Zhang
,
Y. D.
,
O'Dell
,
W.
,
Ng
,
W. S.
, and
Yu
,
Y.
,
2005
, “
Effects of Tip Geometry of Surgical Needles: An Assessment of Force and Deflection
,”
Third European Medical and Biological Engineering Conference
, Prague Czech Republic (
EMBEC
), Prague, Nov. 20–25, pp.
1641
1644
.https://pdfs.semanticscholar.org/8af9/0dbff3a9c1f73bdceeaf76abfd9e7831119c.pdf
14.
McGill
,
C. S.
,
Schwartz
,
J. A.
,
Moore
,
J. Z.
,
McLaughlin
,
P. W.
, and
Shih
,
A. J.
,
2012
, “
Effects of Insertion Speed and Trocar Stiffness on the Accuracy of Needle Position for Brachytherapy
,”
Med. Phys.
,
39
(
4
), pp.
1811
1817
.
15.
McGill
,
C. S.
,
Schwartz
,
J. A.
,
Moore
,
J. Z.
,
McLaughlin
,
P. W.
, and
Shih
,
A. J.
,
2011
, “
Precision Grid and Hand Motion for Accurate Needle Insertion in Brachytherapy
,”
Med. Phys.
,
38
(
8
), pp.
4749
4759
.
16.
Reyssat
,
E.
,
Tallinen
,
T.
,
Le Merrer
,
M.
, and
Mahadevan
,
L.
,
2012
, “
Slicing Softly With Shear
,”
Phys. Rev. Lett.
,
109
(
24
), p.
244301
.
17.
Mguil-Touchal
,
S.
,
Morestin
,
F.
, and
Brunet
,
M.
,
1997
, “
Various Experimental Applications of Digital Image Correlation Method
,”
CMEM
,
97
, pp.
45
58
.https://www.witpress.com/Secure/elibrary/papers/CMEM97/CMEM97005FU.pdf
18.
Ogden
,
R. W.
,
1972
, “
Large Deformation Isotropic Elasticity—On the Correlation of Theory and Experiment for Incompressible Rubberlike Solids
,”
Proc. R. Soc. London, Ser. A, Math. Phys. Sci.
,
326
(
1567
), pp.
565
584
.
19.
Han
,
P.
,
2014
, “
Mechanics of Soft Tissue Cutting in Needle Insertion
,” Ph.D. thesis, Northwestern University, Evanston, IL.
20.
Azar
,
T.
, and
Hayward
,
V.
,
2008
, “
Estimation of the Fracture Toughness of Soft Tissue From Needle Insertion
,”
Biomedical Simulation
, Vol.
5104
,
Springer
,
Berlin
, pp.
166
175
.
21.
Desai
,
P.
,
2007
,
Recent Trends in Obstetrics and Gynecology
,
B.I. Publications Pvt. Limited
,
New Delhi, India
.
You do not currently have access to this content.