Accurate force simulation is essential to haptic simulators for surgical training. Factors such as tissue inhomogeneity pose unique challenges for simulating needle forces. To aid in the development of haptic needle insertion simulators, a handheld force sensing syringe was created to measure the motion and forces of needle insertions. Five needle insertions were performed into the neck of a cadaver using the force sensing syringe. Based on these measurements a piecewise exponential needle force characterization, was implemented into a haptic central venous catheterization (CVC) simulator. The haptic simulator was evaluated through a survey of expert surgeons, fellows, and residents. The maximum needle insertion forces measured ranged from 2.02 N to 1.20 N. With this information, four characterizations were created representing average, muscular, obese, and thin patients. The median survey results showed that users statistically agreed that “the robotic system made me sensitive to how patient anatomy impacts the force required to advance needles in the human body.” The force sensing syringe captured force and position information. The information gained from this syringe was able to be implemented into a haptic simulator for CVC insertions, showing its utility. Survey results showed that experts, fellows, and residents had an overall positive outlook on the haptic simulator's ability to teach haptic skills.

References

1.
Kunkler
,
K.
,
2006
, “
The Role of Medical Simulation: An Overview
,”
Int. J. Med. Rob. Comput. Assisted Surg.
,
2
(
3
), pp.
203
210
.
2.
Coles
,
T. R.
,
Meglan
,
D.
, and
John
,
N. W.
,
2011
, “
The Role of Haptics in Medical Training Simulators: A Survey of the State of the Art
,”
IEEE Trans. Haptics
,
4
(
1
), pp.
51
66
.
3.
Duffy
,
A. J.
,
Hogle
,
N. J.
,
McCarthy
,
H.
,
Lew
,
J. I.
,
Egan
,
A.
,
Christos
,
P.
, and
Fowler
,
D. L.
,
2005
, “
Construct Validity for the LAPSIM Laparoscopic Surgical Simulator
,”
Surg. Endoscopy Other Interventional Tech.
,
19
(
3
), pp.
401
405
.
4.
Coles
,
T. R.
,
John
,
N. W.
,
Gould
,
D. A.
, and
Caldwell
,
D. G.
,
2011
, “
Integrating Haptics With Augmented Reality in a Femoral Palpation and Needle Insertion Training Simulation
,”
IEEE Trans. Haptics
,
4
(
3
), pp.
199
209
.
5.
Roth Monzon
,
E. L.
,
Dumas
,
C.
,
Chellah
,
A.
, and
Cao
,
C. G. L.
,
2011
, “
Haptic Sensitivity in Needle Insertion: The Effects of Training and Visual Aid
,”
International Skills Conference
, Montpellier, France, Dec. 15–16, pp.
250
253
.
6.
Goksel
,
O.
,
Sapchuk
,
K.
, and
Member
,
S.
,
2011
, “
Haptic Simulator for Prostate Brachytherapy With Simulated Needle and Probe Interaction
,”
IEEE Trans. Haptics
,
4
(
3
), pp.
188
198
.
7.
Pepley
,
D.
,
Yovanoff
,
M.
,
Mirkin
,
K.
,
Miller
,
S.
,
Han
,
D.
, and
Moore
,
J.
,
2016
, “
A Virtual Reality Haptic Robotic Simulator for Central Venous Catheterization Training
,”
ASME J. Med. Devices
,
10
(
3
), p.
030937
.
8.
Okamura
,
A. M.
,
Simone
,
C.
, and
O'Leary
,
M. D.
,
2004
, “
Force Modeling for Needle Insertion Into Soft Tissue
,”
IEEE Trans. Biomed. Eng.
,
51
(
10
), pp.
1707
1716
.
9.
Heverly
,
M.
,
Dupont
,
P.
, and
Triedman
,
J.
,
2005
, “
Trajectory Optimization for Dynamic Needle Insertion
,” IEEE International Conference on Robotics and Automation (
ICRA
), Barcelona, Spain, Apr. 18–22, pp.
1646
1651
.
10.
Jin
,
X.
,
Joldes
,
G. R.
,
Miller
,
K.
, and
Wittek
,
A.
,
2013
, “
3D Algorithm for Simulation of Soft Tissue Cutting
,”
Computational Biomechanics for Medicine: Models Algorithms Implementation
, Springer, New York, pp.
49
46
.
11.
Sharifi Sedeh
,
R.
,
Ahmadian
,
M. T.
, and
Janabi-Sharifi
,
F.
,
2010
, “
Modeling, Simulation, and Optimal Initiation Planning for Needle Insertion Into the Liver
,”
ASME J. Biomech. Eng.
,
132
(
4
), p.
041001
.
12.
Patriciu
,
A.
,
2012
, “
CUDA Accelerated Simulation of Needle Insertions in Deformable Tissue
,”
J. Phys.: Conf. Ser.
,
385
(
1
), p.
012006
.
13.
Xu
,
J.
,
Wang
,
L.
,
Wong
,
K. C. L.
, and
Shi
,
P.
, 2010, “
A Meshless Framework for Bevel-Tip Flexible Needle Insertion Through Soft Tissue
,” Third IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics (
BioRob
), Tokyo, Japan, Sept. 26–29, pp.
753
758
.
14.
Gordon
,
A.
,
Kim
,
I.
,
Barnett
,
A. C.
, and
Moore
,
J. Z.
,
2015
, “
Needle Insertion Force Model Haptic Simulation
,”
ASME
Paper No. MSEC2015-9352.
15.
Graham
,
A. S.
,
Ozment
,
C.
,
Tegtmeyer
,
K.
,
Lai
,
S.
, and
Braner
,
D. A. V.
,
2007
, “
Central Venous Catheterization
,”
N. Engl. J. Med.
,
356
(
21
), p.
e21
.
You do not currently have access to this content.