The CardioMEMS heart failure (HF) system was tested for cardiac output (CO) measurement accuracy using an in vitro mock circulatory system. A software algorithm calculates CO based on analysis of the pressure waveform as measured from the pulmonary artery, where the CardioMEMS system resides. Calculated CO was compared to that from reference flow probe in the circulatory system model. CO measurements were compared over a clinically relevant range of stroke volumes and heart rates with normal, pulmonary hypertension (PH), decompensated left heart failure (DLHF), and combined DHLF + PH hemodynamic conditions. The CardioMEMS CO exhibited minimal fixed and proportional bias.
Issue Section:
Research Papers
References
1.
Abraham
, W. T.
, Adamson
, P. B.
, Bourge
, R. C.
, Aaron
, M. F.
, Costanzo
, M. R.
, Stevenson
, L. W.
, Strickland
, W.
, Neelagaru
, S.
, Raval
, N.
, Krueger
, S.
, Weiner
, S.
, Shavelle
, D.
, Jeffries
, B.
, and Yadav
, J. S.
, 2011
, “Wireless Pulmonary Artery Haemodynamic Monitoring in Chronic Heart Failure: A Randomised Controlled Trial
,” Lancet
, 377
(9766
), pp. 658
–666
.2.
Borges
, A. C.
, Wensel
, R.
, Opitz
, C.
, Bauer
, U.
, Baumann
, G.
, and Kleber
, F. X.
, 1997
, “Relationship Between Haemodynamics and Morphology in Pulmonary Hypertension. A Quantitative Intravascular Ultrasound Study
,” Eur. Heart J.
, 18
(12
), pp. 1988
–1994
.3.
Sanz
, J.
, Kariisa
, M.
, Dellegrottaglie
, S.
, Prat-González
, S.
, Garcia
, M. J.
, Fuster
, V.
, and Rajagopalan
, S.
, 2009
, “Evaluation of Pulmonary Artery Stiffness in Pulmonary Hypertension With Cardiac Magnetic Resonance
,” JACC Cardiovasc. Imaging
, 2
(3
), pp. 286
–295
.4.
Milnor
, W. R.
, Jose
, A. D.
, and Mcgaff
, C. J.
, 1960
, “Pulmonary Vascular Volume, Resistance, and Compliance in Man
,” Circulation
, 22
(1
), pp. 130
–137
.5.
Hall
, J. E.
, and Guyton
, A. C.
, 2011
, Guyton and Hall Textbook of Medical Physiology
, Saunders/Elsevier
, Philadelphia, PA
.6.
Rabbah
, J. P.
, Saikrishnan
, N.
, and Yoganathan
, A. P.
, 2013
, “A Novel Left Heart Simulator for the Multi-Modality Characterization of Native Mitral Valve Geometry and Fluid Mechanics
,” Ann. Biomed. Eng.
, 41
(2
), pp. 305
–315
.7.
Santhanakrishnan
, A.
, Maher
, K. O.
, Tang
, E.
, Khiabani
, R. H.
, Johnson
, J.
, and Yoganathan
, A. P.
, 2013
, “Hemodynamic Effects of Implanting a Unidirectional Valve in the Inferior Vena Cava of the Fontan Circulation Pathway: An In Vitro Investigation
,” Am. J. Physiol. Heart Circ. Physiol.
, 305
(10
), pp. H1538
–H1547
.8.
Zannoli
, R.
, Corazza
, I.
, and Branzi
, A.
, 2009
, “Mechanical Simulator of the Cardiovascular System
,” Phys. Med.
, 25
(2
), pp. 94
–100
.9.
Hamilton
, W. F.
, and Remington
, J. W.
, 1946
, “The Measurement of the Stroke Volume from the Pressure Pulse
,” Am. J. Physiol.
, 148
(1
), pp. 14
–24
.10.
Remington
, J. W.
, and Noback
, C. R.
, 1948
, “Volume Elasticity Characteristics of the Human Aorta and Prediction of the Stroke Volume From the Pressure Pulse
,” Am. J. Physiol.
, 153
(2
), pp. 298
–308
.11.
Warner
, H. R.
, Swan
, H. J. C.
, Connolly
, D. C.
, Tompkins
, R. G.
, and Wood
, E. H.
, 1953
, “Quantitation of Beat-to-Beat Changes in Stroke Volume From the Aortic Pulse Contour in Man
,” J. Appl. Physiol.
, 5
(9
), pp. 495
–507
.12.
Herd
, J. A.
, Leclair
, N. R.
, and Simon
, W.
, 1966
, “Arterial Pressure Pulse Contours During Hemorrhage in Anesthetized Dogs
,” J. Appl. Physiol.
, 21
(6
), pp. 1864
–1868
.13.
Wiener
, F.
, Morkin
, E.
, Skalak
, R.
, and Fishman
, A. P.
, 1966
, “Wave Propagation in the Pulmonary Circulation
,” Circ. Res.
, 19
(4
), pp. 834
–850
.14.
Kouchoukos
, N. T.
, Sheppard
, L. C.
, and McDonald
, D. A.
, 1970
, “Estimation of Stroke Volume in the Dog by a Pulse Contour Method
,” Circ. Res.
, 26
(5
), pp. 611
–623
.15.
Alderman
, E. L.
, Branzi
, A.
, Sanders
, W.
, Brown
, B. W.
, and Harrison
, D. C.
, 1972
, “Evaluation of the Pulse-Contour Method of Determining Stroke Volume in Man
,” Circulation
, 46
(3
), pp. 546
–558
.16.
Zacharoulis
, A. A.
, Evans
, T. R.
, Ziady
, G. M.
, Coltart
, D. J.
, and Shillingford
, J. P.
, 1975
, “Measurement of Stroke Volume From Pulmonary Artery Pressure Record in Man
,” Br. Heart J.
, 37
(1
), pp. 20
–25
.17.
Bourgeois
, M. J.
, Gilbert
, B. K.
, Von Bernuth
, G.
, and Wood
, E. H.
, 1976
, “Continuous Determination of Beat to Beat Stroke Volume From Aortic Pressure Pulses in the Dog
,” Circ. Res.
, 39
(1
), pp. 15
–24
.18.
DeLoskey
, A. F.
, Nichols
, W. W.
, Conti
, C. R.
, and Pepine
, C. J.
, 1978
, “Estimation of Beat-to-Beat Stroke Volume From the Pulmonary Arterial Pressure Contour in Man
,” Med. Biol. Eng. Comput.
, 16
(6
), pp. 707
–714
.19.
Murgo
, J. P.
, Westerhof
, N.
, Giolma
, J. P.
, and Altobelli
, S. A.
, 1980
, “Aortic Input Impedance in Normal Man: Relationship to Pressure Wave Forms
,” Circulation
, 62
(1
), pp. 105
–116
.20.
Tannenbaum
, G. A.
, Mathews
, D.
, and Weissman
, C.
, 1993
, “Pulse Contour Cardiac Output in Surgical Intensive Care Unit Patients
,” J. Clin. Anesth.
, 5
(6
), pp. 471
–478
.21.
Karamanoglu
, M.
, and Feneley
, M. P.
, 1999
, “Late Systolic Pressure Augmentation: Role of Left Ventricular Outflow Patterns
,” Am. J. Physiol.—Heart Circ. Physiol.
, 277
, pp. H481
–H487
.22.
Wonisch
, M.
, Fruhwald
, F. M.
, Maier
, R.
, Watzinger
, N.
, Hödl
, R.
, Kraxner
, W.
, Perthold
, W.
, and Klein
, W. W.
, 2005
, “Continuous Haemodynamic Monitoring During Exercise in Patients With Pulmonary Hypertension
,” Int. J. Cardiol.
, 101
(3
), pp. 415
–420
.23.
Karamanoglu
, M.
, McGoon
, M.
, Frantz
, R. P.
, Benza
, R. L.
, Bourge
, R. C.
, Barst
, R. J.
, Kjellström
, B.
, and Bennett
, T. D.
, 2007
, “Right Ventricular Pressure Waveform and Wave Reflection Analysis in Patients With Pulmonary Arterial Hypertension
,” Chest
, 132
(1
), pp. 37
–43
.24.
Karamanoglu
, M.
, Bennett
, T. D.
, Ståhlberg
, M.
, Splett
, V.
, Kjellström
, B.
, Linde
, C.
, and Braunschweig
, F.
, 2011
, “Estimation of Cardiac Output in Patients With Congestive Heart Failure by Analysis of Right Ventricular Pressure Waveforms
,” Biomed. Eng. Online
, 10
, p. 36
.25.
Ohlsson
, A.
, Nordlander
, R.
, Bennett
, T. D.
, Bitkover
, C.
, Kjellström
, B.
, Lee
, B.
, and Rydén
, L.
, 1998
, “Continuous Ambulatory Haemodynamic Monitoring With an Implantable System. The Feasibility of a New Technique
,” Eur. Heart J.
, 19
(1
), pp. 174
–184
.26.
Karamanoglu
, M.
, and Bennett
, T. D.
, 2006
, “A Right Ventricular Pressure Waveform Based Pulse Contour Cardiac Output Algorithm in Canines.
,” Cardiovasc. Eng.
, 6
(3
), pp. 83
–92
.27.
Westerhof
, N.
, Lankhaar
, J.-W.
, and Westerhof
, B. E.
, 2009
, “The Arterial Windkessel
,” Med. Biol. Eng. Comput.
, 47
(2
), pp. 131
–141
.Copyright © 2016 by ASME
You do not currently have access to this content.