The CardioMEMS heart failure (HF) system was tested for cardiac output (CO) measurement accuracy using an in vitro mock circulatory system. A software algorithm calculates CO based on analysis of the pressure waveform as measured from the pulmonary artery, where the CardioMEMS system resides. Calculated CO was compared to that from reference flow probe in the circulatory system model. CO measurements were compared over a clinically relevant range of stroke volumes and heart rates with normal, pulmonary hypertension (PH), decompensated left heart failure (DLHF), and combined DHLF + PH hemodynamic conditions. The CardioMEMS CO exhibited minimal fixed and proportional bias.

References

1.
Abraham
,
W. T.
,
Adamson
,
P. B.
,
Bourge
,
R. C.
,
Aaron
,
M. F.
,
Costanzo
,
M. R.
,
Stevenson
,
L. W.
,
Strickland
,
W.
,
Neelagaru
,
S.
,
Raval
,
N.
,
Krueger
,
S.
,
Weiner
,
S.
,
Shavelle
,
D.
,
Jeffries
,
B.
, and
Yadav
,
J. S.
,
2011
, “
Wireless Pulmonary Artery Haemodynamic Monitoring in Chronic Heart Failure: A Randomised Controlled Trial
,”
Lancet
,
377
(
9766
), pp.
658
666
.
2.
Borges
,
A. C.
,
Wensel
,
R.
,
Opitz
,
C.
,
Bauer
,
U.
,
Baumann
,
G.
, and
Kleber
,
F. X.
,
1997
, “
Relationship Between Haemodynamics and Morphology in Pulmonary Hypertension. A Quantitative Intravascular Ultrasound Study
,”
Eur. Heart J.
,
18
(
12
), pp.
1988
1994
.
3.
Sanz
,
J.
,
Kariisa
,
M.
,
Dellegrottaglie
,
S.
,
Prat-González
,
S.
,
Garcia
,
M. J.
,
Fuster
,
V.
, and
Rajagopalan
,
S.
,
2009
, “
Evaluation of Pulmonary Artery Stiffness in Pulmonary Hypertension With Cardiac Magnetic Resonance
,”
JACC Cardiovasc. Imaging
,
2
(
3
), pp.
286
295
.
4.
Milnor
,
W. R.
,
Jose
,
A. D.
, and
Mcgaff
,
C. J.
,
1960
, “
Pulmonary Vascular Volume, Resistance, and Compliance in Man
,”
Circulation
,
22
(
1
), pp.
130
137
.
5.
Hall
,
J. E.
, and
Guyton
,
A. C.
,
2011
,
Guyton and Hall Textbook of Medical Physiology
,
Saunders/Elsevier
,
Philadelphia, PA
.
6.
Rabbah
,
J. P.
,
Saikrishnan
,
N.
, and
Yoganathan
,
A. P.
,
2013
, “
A Novel Left Heart Simulator for the Multi-Modality Characterization of Native Mitral Valve Geometry and Fluid Mechanics
,”
Ann. Biomed. Eng.
,
41
(
2
), pp.
305
315
.
7.
Santhanakrishnan
,
A.
,
Maher
,
K. O.
,
Tang
,
E.
,
Khiabani
,
R. H.
,
Johnson
,
J.
, and
Yoganathan
,
A. P.
,
2013
, “
Hemodynamic Effects of Implanting a Unidirectional Valve in the Inferior Vena Cava of the Fontan Circulation Pathway: An In Vitro Investigation
,”
Am. J. Physiol. Heart Circ. Physiol.
,
305
(
10
), pp.
H1538
H1547
.
8.
Zannoli
,
R.
,
Corazza
,
I.
, and
Branzi
,
A.
,
2009
, “
Mechanical Simulator of the Cardiovascular System
,”
Phys. Med.
,
25
(
2
), pp.
94
100
.
9.
Hamilton
,
W. F.
, and
Remington
,
J. W.
,
1946
, “
The Measurement of the Stroke Volume from the Pressure Pulse
,”
Am. J. Physiol.
,
148
(
1
), pp.
14
24
.
10.
Remington
,
J. W.
, and
Noback
,
C. R.
,
1948
, “
Volume Elasticity Characteristics of the Human Aorta and Prediction of the Stroke Volume From the Pressure Pulse
,”
Am. J. Physiol.
,
153
(
2
), pp.
298
308
.
11.
Warner
,
H. R.
,
Swan
,
H. J. C.
,
Connolly
,
D. C.
,
Tompkins
,
R. G.
, and
Wood
,
E. H.
,
1953
, “
Quantitation of Beat-to-Beat Changes in Stroke Volume From the Aortic Pulse Contour in Man
,”
J. Appl. Physiol.
,
5
(
9
), pp.
495
507
.
12.
Herd
,
J. A.
,
Leclair
,
N. R.
, and
Simon
,
W.
,
1966
, “
Arterial Pressure Pulse Contours During Hemorrhage in Anesthetized Dogs
,”
J. Appl. Physiol.
,
21
(
6
), pp.
1864
1868
.
13.
Wiener
,
F.
,
Morkin
,
E.
,
Skalak
,
R.
, and
Fishman
,
A. P.
,
1966
, “
Wave Propagation in the Pulmonary Circulation
,”
Circ. Res.
,
19
(
4
), pp.
834
850
.
14.
Kouchoukos
,
N. T.
,
Sheppard
,
L. C.
, and
McDonald
,
D. A.
,
1970
, “
Estimation of Stroke Volume in the Dog by a Pulse Contour Method
,”
Circ. Res.
,
26
(
5
), pp.
611
623
.
15.
Alderman
,
E. L.
,
Branzi
,
A.
,
Sanders
,
W.
,
Brown
,
B. W.
, and
Harrison
,
D. C.
,
1972
, “
Evaluation of the Pulse-Contour Method of Determining Stroke Volume in Man
,”
Circulation
,
46
(
3
), pp.
546
558
.
16.
Zacharoulis
,
A. A.
,
Evans
,
T. R.
,
Ziady
,
G. M.
,
Coltart
,
D. J.
, and
Shillingford
,
J. P.
,
1975
, “
Measurement of Stroke Volume From Pulmonary Artery Pressure Record in Man
,”
Br. Heart J.
,
37
(
1
), pp.
20
25
.
17.
Bourgeois
,
M. J.
,
Gilbert
,
B. K.
,
Von Bernuth
,
G.
, and
Wood
,
E. H.
,
1976
, “
Continuous Determination of Beat to Beat Stroke Volume From Aortic Pressure Pulses in the Dog
,”
Circ. Res.
,
39
(
1
), pp.
15
24
.
18.
DeLoskey
,
A. F.
,
Nichols
,
W. W.
,
Conti
,
C. R.
, and
Pepine
,
C. J.
,
1978
, “
Estimation of Beat-to-Beat Stroke Volume From the Pulmonary Arterial Pressure Contour in Man
,”
Med. Biol. Eng. Comput.
,
16
(
6
), pp.
707
714
.
19.
Murgo
,
J. P.
,
Westerhof
,
N.
,
Giolma
,
J. P.
, and
Altobelli
,
S. A.
,
1980
, “
Aortic Input Impedance in Normal Man: Relationship to Pressure Wave Forms
,”
Circulation
,
62
(
1
), pp.
105
116
.
20.
Tannenbaum
,
G. A.
,
Mathews
,
D.
, and
Weissman
,
C.
,
1993
, “
Pulse Contour Cardiac Output in Surgical Intensive Care Unit Patients
,”
J. Clin. Anesth.
,
5
(
6
), pp.
471
478
.
21.
Karamanoglu
,
M.
, and
Feneley
,
M. P.
,
1999
, “
Late Systolic Pressure Augmentation: Role of Left Ventricular Outflow Patterns
,”
Am. J. Physiol.—Heart Circ. Physiol.
,
277
, pp.
H481
H487
.
22.
Wonisch
,
M.
,
Fruhwald
,
F. M.
,
Maier
,
R.
,
Watzinger
,
N.
,
Hödl
,
R.
,
Kraxner
,
W.
,
Perthold
,
W.
, and
Klein
,
W. W.
,
2005
, “
Continuous Haemodynamic Monitoring During Exercise in Patients With Pulmonary Hypertension
,”
Int. J. Cardiol.
,
101
(
3
), pp.
415
420
.
23.
Karamanoglu
,
M.
,
McGoon
,
M.
,
Frantz
,
R. P.
,
Benza
,
R. L.
,
Bourge
,
R. C.
,
Barst
,
R. J.
,
Kjellström
,
B.
, and
Bennett
,
T. D.
,
2007
, “
Right Ventricular Pressure Waveform and Wave Reflection Analysis in Patients With Pulmonary Arterial Hypertension
,”
Chest
,
132
(
1
), pp.
37
43
.
24.
Karamanoglu
,
M.
,
Bennett
,
T. D.
,
Ståhlberg
,
M.
,
Splett
,
V.
,
Kjellström
,
B.
,
Linde
,
C.
, and
Braunschweig
,
F.
,
2011
, “
Estimation of Cardiac Output in Patients With Congestive Heart Failure by Analysis of Right Ventricular Pressure Waveforms
,”
Biomed. Eng. Online
,
10
, p.
36
.
25.
Ohlsson
,
A.
,
Nordlander
,
R.
,
Bennett
,
T. D.
,
Bitkover
,
C.
,
Kjellström
,
B.
,
Lee
,
B.
, and
Rydén
,
L.
,
1998
, “
Continuous Ambulatory Haemodynamic Monitoring With an Implantable System. The Feasibility of a New Technique
,”
Eur. Heart J.
,
19
(
1
), pp.
174
184
.
26.
Karamanoglu
,
M.
, and
Bennett
,
T. D.
,
2006
, “
A Right Ventricular Pressure Waveform Based Pulse Contour Cardiac Output Algorithm in Canines.
,”
Cardiovasc. Eng.
,
6
(
3
), pp.
83
92
.
27.
Westerhof
,
N.
,
Lankhaar
,
J.-W.
, and
Westerhof
,
B. E.
,
2009
, “
The Arterial Windkessel
,”
Med. Biol. Eng. Comput.
,
47
(
2
), pp.
131
141
.
You do not currently have access to this content.