If a custom hip stem could be designed according to X-ray films, the cost of the hip stem would be reduced, and a simpler designing method could be provided than using computer tomography images. In addition, the problem, which is that hip stems cannot be designed for some revision operations because of metal artifacts in computer tomography images, could be solved. A software system for designing custom hip stems based on X-ray films was developed. In order to verify whether the software system could be used, eleven femurs were used for this study. Hip stems for these eleven femurs were designed by using the software system. Ten of these femurs were taken computer tomography scans directly. According to the data collected from the computer tomography images, models of these ten femurs were rebuilt. Ten hip stem models, designed for these ten femurs, were simulated to be inserted into corresponding femur models. Results show each of the ten hip stems matches its corresponding femur. The hip stem designed for the remaining femur was manufactured and inserted in the remaining femur. Cancellous bone, retained in the matching area, was about 1–1.5 mm thick. From the above verifications, it could be concluded that the software system for designing custom hip stems based on X-ray films could be used to design custom hip stems.

References

1.
Noble
,
P. C.
,
Alexander
,
J. W.
,
Lindahl
,
L. J.
,
Yew
,
D. T.
,
Granberry
,
W. M.
, and
Tullos
,
H. S.
,
1988
, “
The Anatomic Basis of Femoral Component Design
,”
Clin. Orthop. Relat. Res.
,
235
, pp.
148
165
.
2.
Stulberg
,
S. D. F.
,
Stulbert
,
B. N.
, and
Wixson
,
R. L.
,
1989
, “
The Rationale, Design Characteristics and Preliminary Results of a Primary Custom Total Hip Prosthesis
,”
Clin. Orthop. Relat. Res.
,
249
, pp.
79
96
,
3.
Zhu
,
J.-W.
,
Liu
,
F.
,
Dong
,
Q.
,
Xu
,
W.-W.
,
Bai
,
E.-Z.
, and
Huang
,
X.
,
2010
, “
Computer-Assisted Design of Individualized Femoral Prosthesis According to 3D Reconstruction of CT Images
,”
J. Clin. Rehab. Tissue Eng. Res.
,
14
(
35
), pp.
6639
6642
.
4.
Pawlikowski
,
M.
,
Skalski
,
K.
, and
Haraburda
,
M.
,
2003
, “
Process of Hip Joint Prosthesis Design Including Bone Remodeling Phenomenon
,”
Comput. Struct.
,
81
, pp.
8
11
.10.1016/S0045-7949(02)00428-5
5.
Werner
,
A.
, and
Lechniak
,
Z.
,
2000
, “
Design and Manufacture of Anatomical Hip Joint Endostems Using CAD/CAM Systems
,”
J. Mater. Process. Technol.
,
107
, pp.
181
186
.10.1016/S0924-0136(00)00682-8
6.
Iguchi
,
H.
,
Hua
,
J.
, and
Walker
,
P. S.
,
1996
, “
Accuracy of Using Radiographs for Custom Hip Stem Design
,”
J. Arthroplasty
,
11
, pp.
312
332
.10.1016/S0883-5403(96)80084-2
7.
Eggers
,
E. A.
, and
McTighe
,
T.
,
1993
, “
Can Plain X-Rays Generate Reliable Data for Identification and Fabrication of Custom Implants?
,”
Proceedings of the 6th Meeting of the International Society for the Study of Custom Prostheses
,
Amelia Island, FL
, September 29-October 2.
8.
Ma
,
R.
,
Wang
,
D.
,
Xue
W.
, Dai, K., and Wang, C.,
2004
, “
3D Reconstruction of Marrow Cavities in Proximal Femurs Based on X-Ray Films
,”
Beijing Biomed. Eng.
,
23
(
4
), pp.
254
256
.
9.
Ma
,
R.
,
Xue
,
W.
,
Wang
,
D.
,
Dai
,
K.
, and
Wang
,
C.
,
2005
, “
Design and Manufacture of Custom Hip Prostheses Based on Standard X-Ray Films
,”
Int. J. Adv. Manuf. Technol.
,
27
, pp.
70
74
.
10.1007/s00170-004-2168-6
10.
Ma
,
R.
,
Wang
,
D.
,
Xue
,
W.-D.
, Dai, K., and Wang, C.,
2004
, “
Construction of a Database of Average Cross-Sections in Chinese Proximal Femurs
,”
J. Southeast Univ. (English ed.)
,
20
(
2
), pp.
191
194
.
You do not currently have access to this content.