This paper presents a novel articulated drive mechanism (ADM) for a multifunctional natural orifice transluminal endoscopic surgery (NOTES) robotic manipulator. It consists mainly of three major components including a snakelike linkage, motor housing, and an arm connector. The ADM can articulate into complex shapes for improved access to surgical targets. A connector provides an efficient and convenient modularity for insertion and removal of the robot. Four DC motors guide eight cables to steer the robot. The workspace, cable displacement and force transmission relationships are derived. Experimental results give preliminary validation of the feasibility and capability of the ADM system.

References

1.
Georgeson
,
K. E
, and
Robertson
,
D. J.
,
2004
, “
Minimally Invasive Surgery in the Neonate: Review of Current Evidence
,”
Semin. Perinatol.
,
28
(
3
), pp.
212
220
.10.1053/j.semperi.2004.03.008
2.
Wang
,
X.
, and
Meng
,
M. Q.-H.
,
2012
, “
Robotics for Natural Orifice Transluminal Endoscopic Surgery: A Review
,”
J. Rob.
,
2012
, p.
512616
.10.1155/2012/512616
3.
Zhou
,
Y.
,
Ren
,
H.
,
Meng
,
M. Q.-H.
,
Tse
,
Z. T. H.
, and
Yu
,
H.
,
2013
, “
Robotics in Natural Orifice Transluminal Endoscopic Surgery
,”
J. Mech. Med. Biol.
,
13
(
2
), p.
1350044
.10.1142/S0219519413500449
4.
Clark
,
M. P.
,
Qayed
,
E. S.
,
Kooby
,
D. A.
,
Maithel
,
S. K.
, and
Willingham
,
F. F.
,
2012
, “
Natural Orifice Transluminal Endoscopic Surgery in Humans: A Review
,”
Minimally Invasive Surg.
,
2012
, p.
189296
.10.1155/2012/189296
5.
Kalloo
,
A. N.
,
Singh
,
V. K.
,
Jagannath
,
S. B.
,
Niiyama
,
H.
,
Hill
,
S. L.
,
Vaughn
,
C. A.
,
Magee
,
C. A.
, and
Kantsevoy
,
S. V.
,
2004
, “
Flexible Transgastric Peritoneoscopy: A Novel Approach to Diagnostic and Therapeutic Interventions in the Peritoneal Cavity
,”
Gastrointest. Endoscopy
,
60
(
1
), pp.
114
117
.10.1016/S0016-5107(04)01309-4
6.
Rao
,
G. V.
,
Reddy
,
D. N.
, and
Banerjee
,
R.
, 2008. “NOTES: Human Experience,”
Gastrointest. Endosc. Clin. N. Am.
,
18
(2), pp. 361–370.10.1016/j.giec.2008.01.007
7.
Swanstrom
,
L. L.
,
Khajanchee
,
Y.
, and
Abbas
,
M. A.
,
2008
, “
Natural Orifice Transluminal Endoscopic Surgery: The Future of Gastrointestinal Surgery
,”
Perm. J.
,
12
(
2
), pp.
42
47
.
8.
Shang
,
J.
,
Noonan
,
D. P.
,
Payne
,
C.
,
Clark
,
J.
,
Sodergren
,
M. H.
,
Darzi
,
A.
, and
Yang
,
G.-Z.
,
2011
, “
An Articulated Universal Joint Based Flexible Access Robot for Minimally Invasive Surgery
,”
IEEE International Conference on Robotics and Automation
(
ICRA
), Shanghai, China, May 9–13, pp.
1147
1152
.10.1109/ICRA.2011.5980261
9.
Bardaro
,
S. J.
, and
Swanstrom
,
L.
,
2006
, “
Development of Advanced Endoscopes for Natural Orifice Translumenal Endoscopic Surgery (NOTES)
,”
Minimally Invasive Therapy
,
15
(
6
), pp.
378
383
.10.1080/13645700601038069
10.
Degani
,
A.
,
Choset
,
H.
,
Wolf
,
A.
, and
Zenati
,
M. A.
,
2006
, “
Highly Articulated Robotic Probe for Minimally Invasive Surgery
,”
Proceedings of the 2006 IEEE International Conference on Robotics and Automation
(
ICRA 2006
), Orlando, FL, May 15–19, pp.
4167
4172
.10.1109/ROBOT.2006.1642343
11.
Bajo
,
A.
,
Goldman
,
R. E.
,
Wang
,
L.
,
Fowler
,
D.
, and
Simaan
,
N.
,
2012
, “
Integration and Preliminary Evaluation of an Insertable Robotic Effectors Platform for Single Port Access Surgery
,”
IEEE International Conference on Robotics and Automation
(
ICRA
), Saint Paul, MN, May 14–18.10.1109/ICRA.2012.6224986
12.
Li
,
C.
, and
Rahn
,
C. D.
,
2002
, “
Design of Continuous Backbone, Cable-Driven Robots
,”
ASME J. Mech. Des.
,
124
(
2
), pp.
265
271
.10.1115/1.1447546
13.
Kim
,
Y.
,
Cheng
,
S.
,
Kim
,
S.
, and
Iagnemma
,
K.
,
2013
, “
A Stiffness-Adjustable Hyperredundant Manipulator Using a Variable Neutral-Line Mechanism for Minimally Invasive Surgery
,”
IEEE Trans. Rob.
,
30
(
2
), pp.
382
395
.10.1109/TRO.2013.2287975
14.
Lehman
,
A. C.
,
Dumpert
,
J.
,
Wood
,
N. A.
,
Redden
,
L.
,
Visty
,
A. Q.
,
Farritor
,
S.
,
Varnell
,
B.
, and
Oleynikov
,
D.
,
2009
, “
Natural Orifice Cholecystectomy Using a Miniature Robot
,”
Surg. Endoscopy
,
23
(
2
), pp.
260
266
.10.1007/s00464-008-0195-3
15.
Seow
,
C. M.
,
Chin
,
W. J.
,
Nelson
,
C. A.
,
Nakamura
,
A.
,
Farritor
,
S.
, and
Oleynikov
,
D.
,
2013
, “
Articulated Manipulator With Multiple Instruments for Natural Orifice Transluminal Endoscopic Surgery
,”
ASME J. Med. Devices
,
7
(
4
), p.
041004
.10.1115/1.4025183
16.
Chin
,
W. J.
,
Nakamura
,
A.
,
Head
,
M.
,
Farritor
,
S.
,
Oleynikov
,
D.
,
Nelson
,
C. A.
, and
Seow
,
C. M.
,
2011
, “
Multifunctional Articulating Surgical Robot for NOTES
,”
Design of Medical Devices Conference
,
ASME
Paper No. DMD2011-5259.10.1115/DMD2011-5259
17.
Shen
,
T.
,
Warburton
,
K.
,
Pourghodrat
,
A.
,
Nelson
,
C. A.
, and
Oleynikov
,
D.
,
2014
, “
A Novel Articulated Drive Mechanism for Multifunctional NOTES Robot
,”
ASME
Paper No. DMD2014-3562.10.1115/DMD2014-3562
18.
Seow
,
C. M.
,
2011
, “
Robotic Manipulator With Multiple Instruments for Natural Orifice Transluminal Endoscopic Surgery
,” Master's thesis, University of Nebraska—Lincoln, Lincoln, NE.
19.
Simaan
,
N.
,
Taylor
,
R.
, and
Flint
,
P.
,
2004
, “
A Dexterous System for Laryngeal Surgery
,”
IEEE International Conference on Robotics & Automation
(
ICRA '04
), New Orleans, LA, Apr. 26–May 1, pp.
351
357
.10.1109/ROBOT.2004.1307175
20.
Brown
,
J. D.
,
Rosen
,
J.
,
Chang
,
L.
,
Sinanan
,
M. N.
, and
Hannaford
,
B.
,
2004
, “
Quantifying Surgeon Grasping Mechanics in Laparoscopy Using the Blue DRAGON System
,”
Stud. Health Technol.
,
98
, pp.
34
36
.
You do not currently have access to this content.