An experimental investigation into the parameters affecting heat transport in two three-dimensional oscillating heat pipes (OHPs) was implemented. A three-dimensional OHP is one in which the center axis of the circular channels containing the internal working fluid do not lie in the same plane. This novel design allows for more turns in a more compact size. The OHPs in the current investigation is made of copper tubings (3.175 mm outside diameter, 1.65 mm inside diameter) wrapped in a three-dimensional fashion around two copper spreaders that act as the evaporator and condenser. The two OHPs have 10 and 20 turns in both the evaporator and condenser. The 20-turn OHP was filled to 50% of the total volume with a high performance liquid chromatography grade water. Transient and steady state temperature data were recorded at different locations for various parameters. Parameters such as heat input, operating temperature, and filling ratio were varied to determine its effect on the overall heat transport. Neutron radiography was simultaneously implemented to create images of the internal working fluid flow at a rate of 30 frames per second. Results show the average temperature drop from the evaporator to condenser decreases at higher heat inputs due to an increase in temperature throughout the condenser region due to greater oscillations. These large oscillations were visually observed using neutron radiography. As the operating temperature is increased, the thermal resistance is reduced. A decrease in filling ratio tends to create more steady fluid motion; however, the heat transfer performance is reduced.

1.
Wilson
,
C.
,
Borgmeyer
,
B.
,
Winholtz
,
R. A.
,
Ma
,
H. B.
,
Jacobson
,
D.
, and
Hussey
,
D.
, 2008, “
Thermal and Visual Observation of Water and Acetone Oscillating Heat Pipes
,”
ASME Summer Heat Transfer Conference
, Jacksonville, FL, Jul. 10–14.
2.
Charoensawan
,
P.
,
Khandekar
,
S.
,
Groll
,
M.
, and
Terdtoon
,
P.
, 2003, “
Closed Loop Pulsating Heat Pipes Part A: Parametric Experimental Investigations
,”
Appl. Therm. Eng.
1359-4311,
23
, pp.
2009
2020
.
3.
Khandekar
,
S.
,
Dollinger
,
N.
, and
Groll
,
M.
, 2003, “
Understanding Operational Regimes of Closed Loop Pulsating Heat Pipes: An Experimental Study
,”
Appl. Therm. Eng.
1359-4311,
23
(
6
), pp.
707
719
.
4.
Khandekar
,
S.
, and
Groll
,
M.
, 2003, “
On the Definition of Pulsating Heat Pipes: An Overview
,”
Proceedings of the Fifth Minsk International Seminar
, Minsk, Belarus.
5.
Ma
,
H. B.
,
Wilson
,
C.
,
Borgmeyer
,
B.
,
Park
,
K.
,
Yu
,
Q.
,
Choi
,
U. S.
, and
Tirumala
,
M.
, 2006, “
Nanofluid Effect on the Heat Transport Capability in an Oscillating Heat Pipe
,”
Appl. Phys. Lett.
0003-6951,
88
(
14
), p.
143116
.
6.
Xu
,
J. L.
,
Li
,
Y. X.
, and
Wong
,
T. N.
, 2005, “
High Speed Flow Visualization of a Closed Loop Pulsating Heat Pipe
,”
Int. J. Heat Mass Transfer
0017-9310,
48
, pp.
3338
3351
.
7.
Khandekar
,
S.
,
Schneider
,
M.
,
Schafer
,
P.
,
Kulenovic
,
R.
, and
Groll
,
M.
, 2002, “
Thermofluid Dynamic Study of Flat-Plate Closed-Loop Pulsating Heat Pipes
,”
Microscale Thermophys. Eng.
1089-3954,
6
, pp.
303
317
.
You do not currently have access to this content.