The paper presents a novel concept and method of coal combustion process analysis using flame scanners supervision system. The combustion process analysis and diagnostic has a crucial influence on boiler effectiveness, especially in high variance of load demand, which is nowadays a top challenge for coal-fired power plants. The first indicator of combustion inefficiency is flame stability, which can be observed as variation of flame intensity. Nowadays, there are no validated measuring methods dedicated for industrial usage, which are able to give complete information about flame condition. For this reason, the research activity was launched and focused on usage of commercial flame scanners for fast combustion analysis based on on-line flame parameters measuring. The analysis of combustion process was performed for 650 t/h live steam power boiler, which is supplied by five coal mill units. Each coal mill supplies four pulverized coal burners pulverized fuel ((PF) burners). The boiler start-up installation consists of 12 heavy oil burners placed in PF burners equipped with individual supervisory system based on Paragon 105f-1 flame scanners, which gave the possibility to observe and analyze the PF burner flame and oil burner flame individually. The research included numerous tests in which the combustion conditions inside the combustion chamber were changed. During stable load of selected mills, the primary air flow, secondary air dampers, air–coal mixture temperature, and balance were changed. The results of the changes were observed by flame scanners and the available optical parameters of the flame were analyzed: power spectral density, average amplitude (AA) of flame fluctuation, and flame temperature.
Skip Nav Destination
Article navigation
July 2018
Research-Article
Combustion Process Analysis and Diagnostic Using Optical Flame Scanners in Front-Fired Pulverized Coal Boiler
Daniel Nabagło,
Daniel Nabagło
PGE Energia Ciepła S.A., Research &
Development Department,
Ciepłownicza St. 1,
Krakow 31-587, Poland
e-mail: daniel.nabaglo@gkpge.pl
Development Department,
Ciepłownicza St. 1,
Krakow 31-587, Poland
e-mail: daniel.nabaglo@gkpge.pl
Search for other works by this author on:
Teresa Kurek,
Teresa Kurek
Warsaw University of Technology,
Institute of Heat Engineering Faculty of Power
and Aeronautical Engineering,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: teresa.kurek@itc.pw.edu.pl
Institute of Heat Engineering Faculty of Power
and Aeronautical Engineering,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: teresa.kurek@itc.pw.edu.pl
Search for other works by this author on:
Konrad Wojdan
Konrad Wojdan
Institute of Heat Engineering,
Faculty of Power and Aeronautical Engineering,
Warsaw University of Technology,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: konrad.wojdan@itc.pw.edu.pl
Faculty of Power and Aeronautical Engineering,
Warsaw University of Technology,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: konrad.wojdan@itc.pw.edu.pl
Search for other works by this author on:
Daniel Nabagło
PGE Energia Ciepła S.A., Research &
Development Department,
Ciepłownicza St. 1,
Krakow 31-587, Poland
e-mail: daniel.nabaglo@gkpge.pl
Development Department,
Ciepłownicza St. 1,
Krakow 31-587, Poland
e-mail: daniel.nabaglo@gkpge.pl
Teresa Kurek
Warsaw University of Technology,
Institute of Heat Engineering Faculty of Power
and Aeronautical Engineering,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: teresa.kurek@itc.pw.edu.pl
Institute of Heat Engineering Faculty of Power
and Aeronautical Engineering,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: teresa.kurek@itc.pw.edu.pl
Konrad Wojdan
Institute of Heat Engineering,
Faculty of Power and Aeronautical Engineering,
Warsaw University of Technology,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: konrad.wojdan@itc.pw.edu.pl
Faculty of Power and Aeronautical Engineering,
Warsaw University of Technology,
Nowowiejska St. 21/25,
Warsaw 00-665, Poland
e-mail: konrad.wojdan@itc.pw.edu.pl
1Corresponding author.
Contributed by the Advanced Energy Systems Division of ASME for publication in the JOURNAL OF ENERGY RESOURCES TECHNOLOGY. Manuscript received January 19, 2017; final manuscript received December 5, 2017; published online February 27, 2018. Assoc. Editor: Ashwani K. Gupta.
J. Energy Resour. Technol. Jul 2018, 140(7): 072003 (9 pages)
Published Online: February 27, 2018
Article history
Received:
January 19, 2017
Revised:
December 5, 2017
Citation
Nabagło, D., Kurek, T., and Wojdan, K. (February 27, 2018). "Combustion Process Analysis and Diagnostic Using Optical Flame Scanners in Front-Fired Pulverized Coal Boiler." ASME. J. Energy Resour. Technol. July 2018; 140(7): 072003. https://doi.org/10.1115/1.4039096
Download citation file:
Get Email Alerts
Cited By
Analysis of the multiphase flow with condensation in the two-phase ejector condenser using CFD modeling
J. Energy Resour. Technol
Fatigue-Life Estimation of Vertical-Axis Wind Turbine Composite Blades Using Modal Analysis
J. Energy Resour. Technol
Related Articles
Development of the Radially Stratified Flame Core Low NO x Burner: From Fundamentals to Industrial Applications
J. Eng. Gas Turbines Power (April,2004)
Performance Improvements in Cooker-Top Gas Burners for Small Aspect Ratio Changes
J. Thermal Sci. Eng. Appl (December,2017)
A Method for Reduction in the Start-Up Time of a Bubbling Bed Boiler Combustor
J. Energy Resour. Technol (September,2010)
Special Issue: Selected Papers From the 40th International Technical Conference on Clean Coal and Fuel Systems
J. Energy Resour. Technol (July,2016)
Related Chapters
The Impact of Plant Economics on the Design of Industrial Energy Systems
Industrial Energy Systems
Physiology of Human Power Generation
Design of Human Powered Vehicles
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies