Abstract

Airside economizers lower the operating cost of data centers by reducing or eliminating mechanical cooling. It, however, increases the risk of reliability degradation of information technology (IT) equipment due to contaminants. IT Equipment manufacturers have tested equipment performance and guarantee the reliability of their equipment in environments within ISA 71.04-2013 severity level G1 and the ASHRAE recommended temperature-relative humidity (RH) envelope. IT Equipment manufacturers require data center operators to meet all the specified conditions consistently before fulfilling warranty on equipment failure. To determine the reliability of electronic hardware in higher severity conditions, field data obtained from real data centers are required. In this study, a corrosion classification coupon experiment as per ISA 71.04-2013 was performed to determine the severity level of a research data center (RDC) located in an industrial area of hot and humid Dallas. The temperature-RH excursions were analyzed based on time series and weather data bin analysis using trend data for the duration of operation. After some period, a failure was recorded on two power distribution units (PDUs) located in the hot aisle. The damaged hardware and other hardware were evaluated, and cumulative corrosion damage study was carried out. The hypothetical estimation of the end of life of components is provided to determine free air-cooling hours for the site. There was no failure of even a single server operated with fresh air-cooling shows that using evaporative/free air cooling is not detrimental to IT equipment reliability. This study, however, must be repeated in other geographical locations to determine if the contamination effect is location dependent.

References

1.
ASHRAE Technical Committee 9.9
,
2010
, “
ASHRAE DOE Course: Save Energy Now Presentation Series
,” American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Dallas, TX.
2.
Shah
,
J. M.
,
2016
, “
Reliability Challenges in Airside Economization and Oil Immersion Cooling
,”
Master's thesis
,
University of Texas at Arlington
, Arlington, TX.https://www.researchgate.net/publication/315726572_Reliability_challenges_in_airside_economization_and_oil_immersion_cooling
3.
Singh
,
P.
,
Klein
,
L.
,
Agonafer
,
D.
,
Shah
,
J. M.
, and
Pujara
,
K. D.
,
2015
, “
Effect of Relative Humidity, Temperature and Gaseous and Particulate Contaminations on Information Technology Equipment Reliability
,”
ASME
Paper No. IPACK2015-48176.10.1115/IPACK2015-48176
4.
ASHRAE Technical Committee 9.9
,
2004
, “
Thermal Guidelines for Data Processing Environments (ASHRAE Datacom Series)
,” 1st ed., American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, GA.
5.
ASHRAE Technical Committee 9.9
,
2008
, “
Thermal Guidelines for Data Processing Environments (ASHRAE Datacom Series)
,” 2nd ed., American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, GA.
6.
ASHRAE Technical Committee 9.9
,
2012
, “
Thermal Guidelines for Data Processing Environments (ASHRAE Datacom Series)
,” 3rd ed., American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, GA.
7.
Burnett
,
W. H.
,
Sandroff
,
F. S.
, and
D'Egidio
,
S. M.
,
1992
, “
Circuit Failure Due to Fine Dust Mode Particulate Air Pollution
,”
18th International Symposium for Testing and Failure Analysis (ISTFA)
, Los Angeles, CA, Oct. 19–23, pp.
329
333
.
8.
Cole
,
M.
,
Hedlund
,
L.
,
Hutt
,
G.
,
Kiraly
,
T.
,
Klein
,
L.
,
Nickel
,
S.
,
Singh
,
P.
, and
Tofil
,
T.
,
2010
, “
Harsh Environmental Impact on Resistor Reliability
,”
SMTA International Conference
, Orlando, FL, Oct. 24–28, Paper No.
SMTAI10HE2
.https://www.smta.org/knowledge/proceedings_abstract.cfm?PROC_ID=2997
9.
European Union
,
2003
, “
Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
,”
Off. J. Eur. Union
,
L037
, pp.
19
23
.https://ec.europa.eu/environment/waste/rohs_eee/legis_en.htm
10.
Fu
,
H.
,
Chen
,
C.
,
Singh
,
P.
,
Zhang
,
J.
,
Kurella
,
A.
,
Chen
,
X.
,
Jiang
,
X.
,
Burlingame
,
J.
, and
Lee
,
S.
,
2012
, “
Investigation of Factors That Influence Creep Corrosion on Printed Circuit Boards
,”
SMTA Pan Pacific Microelectronics Symposium
, Kauai, HI, Feb. 14–16, Paper No. PP2012_WA1.4.
11.
Shah
,
J. M.
,
Anand
,
R.
,
Saini
,
S.
,
Cyriac
,
R.
,
Agonafer
,
D.
,
Singh
,
P.
, and
Kaler
,
M.
,
2019
, “
Development of a Technique to Measure Deliquescent Relative Humidity of Particulate Contaminants and Determination of the Operating Relative Humidity of a Data Center
,”
ASME
Paper No. IPACK2019-6601.10.1115/IPACK2019-6601
12.
Thirunavakkarasu
,
G.
,
Saini
,
S.
,
Shah
,
J. M.
, and
Agonafer
,
D.
,
2018
, “
Airflow Pattern and Path Flow Simulation of Airborne Particulate Contaminants in a High-Density Data Center Utilizing Airside Economization
,”
ASME
Paper No. IPACK2018-8436.10.1115/IPACK2018-8436
13.
Saini
,
S.
,
2018
, “
Airflow Path and Flow Pattern Analysis of Sub-Micron Particulate Contaminants in a Data Center With Hot Aisle Containment System Utilizing Direct Air Cooling
,”
Master's thesis
,
University of Texas at Arlington
, Arlington, TX.https://rc.library.uta.edu/uta-ir/bitstream/handle/10106/28319/SAINI-THESIS-2018.pdf?sequence=1
14.
Thirunavakkarasu
,
G.
,
2018
, “
Air Flow Pattern and Path Flow Simulation of Airborne Particulate Contaminants in a Cold-Aisle Containment High-Density Data Center Utilizing Airside Economization
,” Master's thesis,
University of Texas at Arlington
, Arlington, TX.
15.
ISA,
1985
, “
Environmental Conditions for Process Measurement and Control Systems: Airborne Contamination
,”
ISA-The Instrumentation Systems, and Automation Society
, ISA, Research Triangle Park, NC, Standard No. ISA-71.04-1985.
16.
ISA,
2013
, “
Environmental Conditions for Process Measurement and Control Systems: Airborne Contaminants
,”
ISA-The Instrumentation Systems, and Automation Society
, ISA, Research Triangle Park, NC, Standard No.
ISA-71.04-2013
.https://webstore.ansi.org/standards/isa/ansiisa71042013
17.
Awe
,
O.
,
2016
, “
The Effects of Temperature and Relative Humidity on Exposure of Legacy and Future Technology Hardware, Under Real Data Center Conditions in an ANSI/ISA Classified G2 Environment
,”
Ph.D. dissertation
,
University of Texas at Arlington
, Arlington, TX. http://hdl.handle.net/10106/26144
18.
Gebrehiwot
,
B. K.
,
2016
, “
Maximizing Use of Air–Side Economization, Direct and Indirect Evaporative Cooling for Energy Efficient Data Centers
,”
Ph.D. dissertation
, University of Texas at Arlington, Arlington, TX. http://hdl.handle.net/10106/25759
19.
Shah
,
J. M.
,
Awe
,
O.
,
Agarwal
,
P.
,
Iziren
,
A.
,
Agonafer
,
D.
,
Singh
,
P.
,
Kannan
,
N.
, and
Kaler
,
M.
,
2016
, “
Qualitative Study of Cumulative Corrosion Damage of IT Equipment in a Data Center Utilizing Air-Side Economizer
,”
ASME
Paper No. IMECE2016-66199.10.1115/IMECE2016-66199
20.
Shah
,
J. M.
,
Awe
,
O.
,
Gebrehiwot
,
B.
,
Agonafer
,
D.
,
Singh
,
P.
,
Kannan
,
N.
, and
Kaler
,
M.
,
2017
, “
Qualitative Study of Cumulative Corrosion Damage of Information Technology Equipment in a Data Center Utilizing Air-Side Economizer Operating in Recommended and Expanded ASHRAE Envelope
,”
ASME J. Electron. Packag.
,
139
(
2
), p.
020903
.10.1115/1.4036363
21.
ASTM
, 2019, “
Standard Test Method for Coulometric Reduction of Surface Films on Metallic Test Samples
,” American Society for Testing and Materials, West Conshohocken, PA, Standard No.
ASTM B825
.10.1520/B0825-19
22.
Shah
,
J. M.
,
Misrak
,
A.
,
Agonafer
,
D.
, and
Kaler
,
M.
,
2019
, “
Identification and Characterization of Particulate Contaminants Found at a Data Center Using Airside Economization
,”
ASME J. Electron. Packag.
,
141
(
3
), p.
031003
.10.1115/1.4043481
23.
Shah
,
J. M.
,
2018
, “
Characterizing Contamination to Expand ASHRAE Envelope in Airside Economization and Thermal and Reliability in Immersion Cooling of Data Centers
,”
Ph.D. dissertation
,
University of Texas at Arlington
, Arlington, TX.https://www.researchgate.net/publication/332951031_CHARACTERIZING_CONTAMINATION_TO_EXPAND_ASHRAE_ENVELOPE_IN_AIRSIDE_ECONOMIZATION_AND_THERM
You do not currently have access to this content.