This paper introduces a control problem of regulation of energy flows in a two-site electricity and heat supply system, where two combined heat and power (CHP) plants are interconnected via electricity and heat flows. The control problem is motivated by recent development of fast operation of CHP plants to provide ancillary services of power system on the order of tens of seconds to minutes. Due to the physical constraint that the responses of the heat subsystem are not necessary as fast as those of the electric subsystem, the target controlled state is not represented by any isolated equilibrium point, implying that stability of the system is lost in the long-term sense on the order of hours. In this paper, we first prove in the context of nonlinear control theory that the state-space model of the two-site system is nonminimum phase due to nonexistence of isolated equilibrium points of the associated zero dynamics. Instead, we locate a one-dimensional (1D) invariant manifold that represents the target controlled flows completely. Then, by utilizing a virtual output under which the state-space model becomes minimum phase, we synthesize a controller that achieves not only the regulation of energy flows in the short-term regime but also stabilization of an equilibrium point in the long-term regime. Effectiveness of the synthesized controller is established with numerical simulations with a practical set of model parameters.

References

1.
Geidl
,
M.
,
Koeppel
,
G.
,
Favre-Perrod
,
P.
,
Klöckl
,
B.
,
Andersson
,
G.
, and
Fröhlich
,
K.
,
2007
, “
Energy Hubs for the Future
,”
IEEE Power Energy Mag.
,
5
(
1
), pp.
24
30
.
2.
O'Malley
,
M.
, and
Kroposki
,
B.
,
2013
, “
Energy Comes Together: The Integration of All Systems
,”
IEEE Power Energy Mag.
,
11
(
5
), pp.
18
23
.
3.
Liu
,
X.
,
Wu
,
J.
,
Jenkins
,
N.
, and
Bagdanavicius
,
A.
,
2016
, “
Combined Analysis of Electricity and Heat Networks
,”
Appl. Energy
,
162
, pp.
1238
1250
.
4.
Geidl
,
M.
, and
Andersson
,
G.
,
2007
, “
Optimal Power Flow of Multiple Energy Carriers
,”
IEEE Trans. Power Syst.
,
22
(
1
), pp.
145
155
.
5.
Chicco
,
G.
, and
Mancarella
,
P.
,
2009
, “
Distributed Multi-Generation: A Comprehensive View
,”
Renewable Sustainable Energy Rev.
,
13
(
3
), pp.
535
551
.
6.
Mancarella
,
P.
,
2014
, “
MES (Multi-Energy Systems): An Overview of Concepts and Evaluation Models
,”
Energy
,
65
, pp.
1
17
.
7.
Hara
,
S.
,
2013
, “
Glocal Control Viewpoint for Integrated Energy System
,”
52nd IEEE Conference on Decision and Control Workshop
,
Florence, Italy
,
Dec. 9
.
8.
Rebours
,
Y. G.
,
Kirschen
,
D. S.
,
Trotignon
,
M.
, and
Rossignol
,
S.
,
2007
, “
A Survey of Frequency and Voltage Control Ancillary Services—Part I: Technical Features
,”
IEEE Trans. Power Syst.
,
22
(
1
), pp.
350
357
.
9.
Galus
,
M. D.
,
Koch
,
S.
, and
Andersson
,
G.
,
2011
, “
Provision of Load Frequency Control by Phevs, Controllable Loads, and a Cogeneration Unit
,”
IEEE Trans. Ind. Electron.
,
58
(
10
), pp.
4568
4582
.
10.
Shinji
,
T.
,
Sekine
,
T.
,
Akisawa
,
A.
,
Kashiwagi
,
T.
,
Fujita
,
G.
, and
Matsubara
,
M.
,
2008
, “
Reduction of Power Fluctuation by Distributed Generation in Micro Grid
,”
Electr. Eng. Jpn.
,
163
(
2
), pp.
22
29
.
11.
Mueller
,
S.
,
Tuth
,
R.
,
Fischer
,
D.
,
Wille-Haussmann
,
B.
, and
Wittwer
,
C.
,
2014
, “
Balancing Fluctuating Renewable Energy Generation Using Cogeneration and Heat Pump Systems
,”
Energy Technol.
,
2
(
1
), pp.
83
89
.
12.
Hoshino
,
H.
,
Susuki
,
Y.
, and
Hikihara
,
T.
,
2014
, “
A Nonlinear Dynamical Model of Two-Sites Electricity and Heat Supply System
,”
International Symposium on Nonlinear Theory and Its Applications
(
NOLTA
),
Luzern, Switzerland
,
Sept. 14–18
, pp.
482
485
.http://www.ieice.org/nolta/symposium/archive/2014/articles/C2L-A2-6065.pdf
13.
Hoshino
,
H.
, and
Susuki
,
Y.
,
2015
, “
Graph-Based Modeling and Analysis of Dynamic Flows in Steam Supply Networks
,”
54th IEEE Conference on Decision and Control
(
CDC
),
Osaka, Japan
,
Dec. 15–18
, pp.
1358
1363
.
14.
Hoshino
,
H.
,
Susuki
,
Y.
, and
Hikihara
,
T.
,
2016
, “
A Lumped-Parameter Model of Multiscale Dynamics in Steam Supply Systems
,”
ASME J. Comput. Nonlinear Dyn.
,
11
(
6
), p.
061018
.
15.
Hoshino
,
H.
,
Susuki
,
Y.
,
Koo
,
T. J.
, and
Hikihara
,
T.
,
2017
, “
Nonlinear Control of Combined Heat and Power Plants in a Two-Site Regional Energy System—Simultaneous Regulation of Electricity and Gas Flows
,”
Trans. ISCIE
,
30
(
5
), pp.
157
166 (
in Japanese).
16.
Isidori
,
A.
,
1995
,
Nonlinear Control Systems
, 3rd ed.,
Springer-Verlag
,
London
.
17.
Sastry
,
S.
,
1999
,
Nonlinear Systems: Analysis, Stability, and Control
,
Springer-Verlag
,
New York
.
18.
Fiorentini
,
L.
, and
Serrani
,
A.
,
2012
, “
Adaptive Restricted Trajectory Tracking for a Non-Minimum Phase Hypersonic Vehicle Model
,”
Automatica
,
48
(
7
), pp.
1248
1261
.
19.
Ilić
,
M. D.
, and
Liu
,
Q.
,
2012
, “
Toward Sensing, Communications and Control Architectures for Frequency Regulation in Systems With Highly Variable Resources
,”
Control and Optimization Methods for Electric Smart Grids
,
A.
Chakrabortty
and
M. D.
Ilić
, eds.,
Springer-Verlag
,
New York
.
20.
Dörfler
,
F.
,
Simpson-Porco
,
J. W.
, and
Bullo
,
F.
,
2016
, “
Breaking the Hierarchy: Distributed Control and Economic Optimality in Microgrids
,”
IEEE Trans. Control Network Syst.
,
3
(
3
), pp.
241
253
.
21.
Stegink
,
T. W.
,
Persis
,
C. D.
, and
van der Schaft
,
A. J.
,
2017
, “
Stabilization of Structure-Preserving Power Networks With Market Dynamics
,”
IFAC-PapersOnLine
,
50
(
1
), pp.
6737
6742.
22.
Persis
,
C. D.
,
Jensen
,
T. N.
,
Ortega
,
R.
, and
Wisniewski
,
R.
,
2014
, “
Output Regulation of Large-Scale Hydraulic Networks
,”
IEEE Trans. Control Syst. Technol.
,
22
(
1
), pp.
238
245
.
23.
Energy Networks Association
,
2015
, “
Active Network Management Good Practice Guide
,” Energy Networks Association,
London
, accessed Jan. 17, 2019, http://www.energynetworks.org/assets/files/news/publications/1500205_ENA_ANM_report_AW_online.pdf
24.
Zhong
,
W.
,
Feng
,
H.
,
Wang
,
X.
,
Wu
,
D.
,
Xue
,
M.
, and
Wang
,
J.
,
2015
, “
Online Hydraulic Calculation and Operation Optimization of Industrial Steam Heating Networks Considering Heat Dissipation in Pipes
,”
Energy
,
87
, pp.
566
577
.
25.
Buoro
,
D.
,
Pinamonti
,
P.
, and
Reini
,
M.
,
2014
, “
Optimization of a Distributed Cogeneration System With Solar District Heating
,”
Appl. Energy
,
124
, pp.
298
308
.
26.
NEDO
,
2018
, “
News Release: NEDO Conducts World's First Technology Demonstration for Hydrogen-Fueled Cogeneration System in Urban Areas
,” NEDO,
Tokyo, Japan
, accessed Mar. 22, 2018, http://www.nedo.go.jp/english/news/AA5en_ 100348.html
27.
Arapostathis
,
A.
,
Sastry
,
S.
, and
Varaiya
,
P.
,
1981
, “
Analysis of Power-Flow Equation
,”
Int. J. Electr. Power Energy Syst.
,
3
(
3
), pp.
115
126
.
28.
Ueda
,
Y.
,
Enomoto
,
T.
, and
Stewart
,
H. B.
,
1992
, “
Chaotic Transients and Fractal Structures Governing Coupled Swing Dynamics
,”
Applied Chaos
,
J. H.
Kim
and
J.
Stringer
, eds.,
Wiley
,
Hoboken, NJ
, pp.
207
218
.
29.
Kundur
,
P.
,
1994
,
Power System Stability and Control
,
McGraw-Hill
,
New York
.
30.
Bujak
,
J.
,
2009
, “
Optimal Control of Energy Losses in Multi-Boiler Steam Systems
,”
Energy
,
34
(
9
), pp.
1260
1270
.
31.
Chinese
,
D.
,
2008
, “
Optimal Size and Layout Planning for District Heating and Cooling Networks With Distributed Generation Options
,”
Int. J. Energy Sector Manage.
,
2
(
3
), pp.
385
419
.
32.
Rowen
,
W. I.
,
1983
, “
Simplified Mathematical Representations of Heavy-Duty Gas Turbines
,”
J. Eng. Power
,
105
(
4
), pp.
865
869
.
33.
Machowski
,
J.
,
Bialek
,
J. W.
, and
Bumby
,
J. R.
,
2008
,
Power System Dynamics: Stability and Control
, 2nd ed.,
Wiley
,
Hoboken, NJ
.
34.
Åström
,
K. J.
, and
Bell
,
R. D.
,
2000
, “
Drum-Boiler Dynamics
,”
Automatica
,
36
(
3
), pp.
363
378
.
35.
Krstic
,
M.
,
Kanellakopoulos
,
I.
, and
Kokotovic
,
P. V.
,
1995
,
Nonlinear and Adaptive Control Design
,
Wiley
,
New York
.
36.
Sepulchre
,
R.
,
Janković
,
M.
, and
Kokotović
,
P. K.
,
1997
,
Constructive Nonlinear Control
,
Springer-Verlag
,
London
.
37.
Chen
,
Z.
, and
Huang
,
J.
,
2015
,
Nonlinear Output Regulation
,
SIAM
,
Philadelphia, PA
.
38.
Kim
,
T. S.
,
Lee
,
D. K.
, and
Ro
,
S. T.
,
2000
, “
Dynamic Behavior Analysis of a Heat Recovery Steam Generator During Start-Up
,”
Int. J. Energy Res.
,
24
(
2
), pp.
137
149
.
39.
Osiadacz
,
A. J.
,
1987
,
Simulation and Analysis of Gas Networks
,
E. F. N. Spon
,
Houston, TX
.
You do not currently have access to this content.