1-20 of 170
Keywords: prosthetics
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Article Type: Research Papers
J Biomech Eng. December 2011, 133(12): 121003.
Published Online: December 21, 2011
... haemodynamics prosthetics shear flow Cardiac valve prosthesis Transvalvular flow Strains Blood damaging potential Heart valves that fail to perform their physiological function correctly can be replaced either by mechanical or biological prosthetic valves. Despite the abundant variety...
Journal Articles
Article Type: Research Papers
J Biomech Eng. December 2011, 133(12): 121001.
Published Online: December 21, 2011
... of the gaps. 17 05 2011 10 11 2011 21 12 2011 27 12 2011 21 12 2011 biological fluid dynamics bone cellular biophysics computational fluid dynamics micromechanics prosthetics tissue engineering Total hip replacement (THR) aseptic loosening osteolysis capsular...
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. October 2011, 133(10): 104503.
Published Online: November 3, 2011
... 2011 27 09 2011 03 11 2011 03 11 2011 biomagnetism biomechanics biomedical materials biomedical measurement bone magnetic sensors orthopaedics patient diagnosis prosthetics total hip replacement aseptic loosening loosening sensor in vivo measurement diagnostic...
Journal Articles
Article Type: Research Papers
J Biomech Eng. September 2011, 133(9): 091002.
Published Online: October 4, 2011
... strategies to improve patellar tendon autograft integration into bone using this model. 21 06 2011 23 08 2011 04 10 2011 04 10 2011 biochemistry biomechanics bone failure (mechanical) mechanical stability molecular biophysics muscle prosthetics proteins surgery tissue...
Journal Articles
Article Type: Research Papers
J Biomech Eng. August 2011, 133(8): 081009.
Published Online: September 20, 2011
... biomechanics bone durability finite element analysis kinematics orthopaedics polymers prosthetics rods (structures) titanium PEEK polyetheretherketone lumbar fusion semi-rigid dynamic stabilization Spinal arthrodesis is intended to provide stability by limiting long term motion...
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. July 2011, 133(7): 074503.
Published Online: July 22, 2011
... carbon fibres filled polymers gait analysis infrared imaging mechanical testing orthopaedics prosthetics strain measurement biomechanics infrared thermography stress strain composite hip implant Metallic hip implants are much stiffer than bone and, thus, carry a higher proportion...
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. June 2011, 133(6): 064504.
Published Online: June 22, 2011
... the lateral condyle. The study proposes a method for predicting the geometry of the femoral condyles with good accuracy. The B-spline model showed best results. 17 11 2010 10 05 2011 30 05 2011 22 06 2011 22 06 2011 bone orthotics physiological models prosthetics splines...
Journal Articles
Article Type: Research Papers
J Biomech Eng. May 2011, 133(5): 051006.
Published Online: April 28, 2011
...Melanie L. Thompson; David Backman; Rickard Branemark; Chris K. Mechefske Osseointegrated transfemoral implants have been introduced as a prosthetic solution for above knee amputees. They have shown great promise, providing an alternative for individuals who could not be accommodated...
Journal Articles
Article Type: Research Papers
J Biomech Eng. April 2011, 133(4): 041009.
Published Online: March 23, 2011
... with rigid leaflets. 05 10 2010 03 02 2011 18 02 2011 23 03 2011 23 03 2011 cardiology haemodynamics haemorheology prosthetics shear modulus Among the different prosthetic heart valves, the mechanical bileaflet heart valve is the most implanted design with more...
Journal Articles
Article Type: Research Papers
J Biomech Eng. April 2011, 133(4): 041002.
Published Online: February 17, 2011
... 01 2011 17 02 2011 17 02 2011 biomedical equipment biomedical imaging blood flow measurement computational fluid dynamics confined flow error analysis haemorheology health and safety jets nozzles prosthetics turbulence viscosity particle image velocimetry...
Journal Articles
Article Type: Research Papers
J Biomech Eng. March 2011, 133(3): 031005.
Published Online: February 7, 2011
... 2010 26 11 2010 22 12 2010 07 02 2011 07 02 2011 biomechanics bone dentistry elastic moduli finite element analysis prosthetics implant design biomechanical surrounding finite element method factorial analysis It is general consensus that low amounts...
Journal Articles
Article Type: Research Papers
J Biomech Eng. February 2011, 133(2): 021010.
Published Online: January 31, 2011
... calibration force sensors physiological models prosthetics surgery vertical ground reaction forces ovine instrumented treadmill sensor implantation activities of daily living Treating injuries to the anterior cruciate ligament (ACL) and its graft replacements remain important clinical...
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. February 2011, 133(2): 024501.
Published Online: January 31, 2011
...A. I. Hussein; J. C. Stranart; S. A. Meguid; E. R. Bogoch Silicone implants are used for prosthetic arthroplasty of metacarpophalangeal (MCP) joints severely damaged by rheumatoid arthritis. Different silicone elastomer MCP implant designs have been developed, including the Swanson and the NeuFlex...
Journal Articles
Article Type: Research Papers
J Biomech Eng. February 2011, 133(2): 021006.
Published Online: January 24, 2011
... measurement biomedical optical imaging biomedical ultrasonics bone Brillouin spectra elasticity prosthetics titanium alloys vanadium alloys bone implant osseointegration elastic wave velocity micro-Brillouin scattering Pure titanium and its alloy (Ti–6Al–4V) are widely used materials...
Journal Articles
Article Type: Research Papers
J Biomech Eng. January 2011, 133(1): 011009.
Published Online: December 23, 2010
... 20 09 2010 25 10 2010 23 12 2010 23 12 2010 anthropometry biological tissues biomechanics bone finite element analysis mechanical contact neurophysiology orthopaedics physiological models prosthetics stress analysis The principal motivations for the use...
Journal Articles
Article Type: Research Papers
J Biomech Eng. January 2011, 133(1): 011012.
Published Online: December 23, 2010
... 28 10 2010 18 11 2010 29 11 2010 23 12 2010 23 12 2010 compressive strength diseases failure (mechanical) injuries prosthetics knee hyperextension anterior cruciate ligament posterior cruciate ligament injury The knee is one of the most frequently...
Journal Articles
Article Type: Research Papers
J Biomech Eng. November 2010, 132(11): 111005.
Published Online: October 15, 2010
... cardiovascular system haemodynamics image reconstruction kinematics medical image processing prosthetics pulsatile flow Patients with heart valve disease commonly undergo surgery to replace their diseased valves with artificial ones. More than half of all the replaced valves are mechanical heart...
Journal Articles
Article Type: Research Papers
J Biomech Eng. October 2010, 132(10): 101006.
Published Online: October 1, 2010
... prosthetics Deep vein thrombosis (DVT) and pulmonary embolism (PE) are collectively referred to as venous thromboembolism (VTE), which is the third leading cause of cardiovascular related death after myocardial infarction and stroke ( 1 ). It is estimated that there are more than 900,000 cases of VTE...
Journal Articles
Article Type: Research Papers
J Biomech Eng. October 2010, 132(10): 101008.
Published Online: October 1, 2010
... prostheses. 24 06 2010 17 08 2010 01 09 2010 01 10 2010 01 10 2010 anthropometry biomechanics biomedical MRI bone correlation methods medical image processing prosthetics meniscus anthropometry sex sizing MRI The meniscus plays an important role...
Journal Articles
Article Type: Research Papers
J Biomech Eng. September 2010, 132(9): 091012.
Published Online: September 1, 2010
... mechanical testing moulding prosthetics To calculate the material properties from mechanical testing data, the length and cross-sectional area of the object are needed. Measuring the cross-sectional area is simple for items such as metal rods, but it is not as straightforward for soft tissues...