Skip Nav Destination
Issues
March 2013
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Research Papers
A Feature-Based Morphing Methodology for Computationally Modeled Biological Structures Applied to Left Atrial Fiber Directions
J Biomech Eng. March 2013, 135(3): 031001.
doi: https://doi.org/10.1115/1.4023369
Topics:
Algorithms
,
Anisotropy
,
Biological tissues
,
Fibers
,
Finite element methods
,
Finite element model
,
Geometry
,
Simulation
,
Stress
,
Topology
Localization of Viscous Behavior and Shear Energy Dissipation in Articular Cartilage Under Dynamic Shear Loading
J Biomech Eng. March 2013, 135(3): 031002.
doi: https://doi.org/10.1115/1.4007454
Topics:
Biological tissues
,
Cartilage
,
Energy dissipation
,
Shear (Mechanics)
,
Shear modulus
,
Displacement
Optimized Design of an Instrumented Spatial Linkage that Minimizes Errors in Locating the Rotational Axes of the Tibiofemoral Joint: A Computational Analysis
J Biomech Eng. March 2013, 135(3): 031003.
doi: https://doi.org/10.1115/1.4023135
Determination and Modeling of the Inelasticity Over the Length of the Porcine Carotid Artery
J Biomech Eng. March 2013, 135(3): 031004.
doi: https://doi.org/10.1115/1.4023371
Topics:
Biological tissues
,
Carotid arteries
,
Constitutive equations
,
Cycles
,
Modeling
,
Stress
,
Damage
Comparative Study on Tube-Load Modeling of Arterial Hemodynamics in Humans
Mohammad Rashedi, Nima Fazeli, Alyssa Chappell, Shaohua Wang, Roderick MacArthur, M. Sean McMurtry, Barry A. Finegan, Jin-Oh Hahn
J Biomech Eng. March 2013, 135(3): 031005.
doi: https://doi.org/10.1115/1.4023373
Topics:
Hemodynamics
,
Stress
,
Modeling
Technical Briefs
Tendon Fascicles Exhibit a Linear Correlation Between Poisson's Ratio and Force During Uniaxial Stress Relaxation
J Biomech Eng. March 2013, 135(3): 034501.
doi: https://doi.org/10.1115/1.4023134
Topics:
Poisson ratio
,
Relaxation (Physics)
,
Stress
,
Tendons
,
Biological tissues
,
Viscoelasticity
Left Ventricular Pressure Gating in Ovine Cardiac Studies: A Software-Based Method
Gabriel Acevedo-Bolton, Takamaro Suzuki, Deepak Malhotra, Zhihong Zhang, Arthur W. Wallace, Julius M. Guccione, David A. Saloner, Mark B. Ratcliffe
J Biomech Eng. March 2013, 135(3): 034502.
doi: https://doi.org/10.1115/1.4023370
Topics:
Biological tissues
,
Computer software
,
Pressure
,
Signals
,
Circuits
,
Noise (Sound)
,
Imaging
,
Magnetic resonance imaging
A Model of the Recruitment-Derecruitment and Volume of Lung Units in an Excised Lung as it is Inflated-Deflated Between Minimum and Maximum Lung Volume
J Biomech Eng. March 2013, 135(3): 034503.
doi: https://doi.org/10.1115/1.4023372
Hydrodynamic Modeling of Targeted Magnetic-Particle Delivery in a Blood Vessel
J Biomech Eng. March 2013, 135(3): 034504.
doi: https://doi.org/10.1115/1.4023137
In Vitro Pulsatility Analysis of Axial-Flow and Centrifugal-Flow Left Ventricular Assist Devices
J Biomech Eng. March 2013, 135(3): 034505.
doi: https://doi.org/10.1115/1.4023525
Topics:
Axial flow
,
Flow (Dynamics)
,
Pumps
,
Ventricular assist devices
,
Pressure
Design Innovation Papers
Combined in Vivo/in Vitro Method to Study Anteriomedial Bundle Strain in the Anterior Cruciate Ligament Using a Dynamic Knee Simulator
J Biomech Eng. March 2013, 135(3): 035001.
doi: https://doi.org/10.1115/1.4023520
Topics:
Anterior cruciate ligament
,
Knee
,
Muscle
,
Simulation