Abstract

The spacing between the median nerve and transverse carpal ligament (TCL) within the carpal tunnel can potentially affect the nerve morphology. This study aimed to quantify the spatial relationship between the median nerve and transverse carpal ligament in asymptomatic hands. Twelve subjects were recruited to image the carpal tunnel using robot-assisted ultrasound. The median nerve and TCL were segmented from each image and three-dimensionally reconstructed using kinematic information from the robot. The TCL-median nerve distance, nerve cross-sectional area, circularity, and position were measured along the entirety of the nerve length within the carpal tunnel. Results were averaged at every 5% of nerve length. At the nerve length percentages of 0% (distal), 25%, 50%, 75%, and 100% (proximal), the TCL-median nerve distance (±SD) was 0.7 ± 0.4, 0.7 ± 0.2, 0.5 ± 0.2, 0.5 ± 0.2, and 0.6 ± 0.3 mm, respectively. The corresponding nerve cross-sectional area was 9.4 ± 1.9, 10.6 ± 2.6, 11.2 ± 2.1, 11.2 ± 1.7, and 9.7 ± 1.9 mm2. A one-way analysis of variance showed no significant differences between the respective percentages of nerve length for TCL-median nerve distance (p = 0.219) and cross-sectional area (p = 0.869). Significant (p < 0.0001) but weak correlations were observed between the TCL-median nerve distance with cross-sectional area (r = −0.247) and circularity (r = −0.244). This study shows that the healthy median nerve morphology is consistent along the continuous nerve length within the carpal tunnel, supporting the use of 2D imaging in the evaluation of the healthy nerve.

References

1.
Duncan
,
I.
,
Sullivan
,
P.
, and
Lomas
,
F.
,
1999
, “
Sonography in the Diagnosis of Carpal Tunnel Syndrome
,”
AJR, Am. J. Roentgenol.
,
173
(
3
), pp.
681
684
.10.2214/ajr.173.3.10470903
2.
Luckhaupt
,
S.
,
Dahlhamer
,
J.
,
Ward
,
B.
,
Sweeney
,
M.
,
Sestito
,
J.
, and
Calvert
,
J.
,
2013
, “
Prevalence and Work-Relatedness of Carpal Tunnel Syndrome in the Working Population, United States, 2010 National Health Interview Survey
,”
Am. J. Ind. Med.
,
56
(
6
), pp.
615
624
.10.1002/ajim.22048
3.
Yao
,
B.
,
Gan
,
K.
,
Lee
,
A.
, and
Roll
,
S.
,
2020
, “
Comparing Shape Categorization to Circularity Measurement in the Evaluation of Median Nerve Compression Using Sonography
,”
J. Diagn. Med. Sonography
,
36
(
3
), pp.
224
232
.10.1177/8756479319898471
4.
Sacks
,
J.
,
Kuo
,
Y.
,
Mclean
,
K.
,
Wollstein
,
R.
, and
Lee
,
W.
,
2006
, “
Anatomical Relationships Among the Median Nerve Thenar Branch, Superficial Palmar Arch, and Transverse Carpal Ligament
,”
Plast. Reconstr. Surg.
,
120
(
3
), pp.
713
718
.10.1097/01.prs.0000270305.37677.e7
5.
Olave
,
E.
,
Del Sol
,
M.
,
Gabrielli
,
C.
,
Mandiola
,
E.
, and
Rodrigues
,
C.
,
2001
, “
Biometric Study of the Relationships Between Palmar Neurovascular Structures, the Flexor Retinaculum and the Distal Wrist Crease
,”
J. Anat.
,
198
(
6
), pp.
737
741
.10.1046/j.1469-7580.2001.19860737.x
6.
Hung Ng
,
A. W.
,
Griffith
,
J. F.
,
Tsoi
,
C.
,
Fong
,
R. C. W.
,
Kay Mak
,
M. C.
,
Tse
,
W. L.
, and
Cheong Ho
,
P.
,
2021
, “
Ultrasonography Findings of the Carpal Tunnel After Endoscopic Carpal Tunnel Release for Carpal Tunnel Syndrome
,”
Korean J. Radiol.
,
22
(
7
), pp.
1132
1141
.10.3348/kjr.2020.1039
7.
Inui
,
A.
,
Nishimoto
,
H.
,
Mifune
,
Y.
,
Kokubu
,
T.
,
Sakata
,
R.
, and
Kurosaka
,
M.
,
2016
, “
Ultrasound Measurement of Median Nerve Cross-Sectional Area at the Inlet and Outlet of Carpal Tunnel After Carpal Tunnel Release Compared to Electrodiagnostic Findings
,”
Arch. Orthop. Trauma Surg.
,
136
(
9
), pp.
1325
1330
.10.1007/s00402-016-2514-9
8.
Huisstede
,
B.
,
Hoogvliet
,
P.
,
Randsdorp
,
M.
,
Glerum
,
S.
,
van Middelkoop
,
M.
, and
Koes
,
B.
,
2010
, “
Carpal Tunnel Syndrome. Part I: Effectiveness of Nonsurgical Treatments—A Systematic Review
,”
Arch. Phys. Med. Rehabil.
,
91
(
7
), pp.
981
1004
.10.1016/j.apmr.2010.03.022
9.
Marquardt
,
T.
,
Evans
,
P.
,
Seitz
,
W.
, Jr.
, and
Li
,
Z. M.
,
2016
, “
Carpal Arch and Median Nerve Changes During Radioulnar Wrist Compression in Carpal Tunnel Syndrome Patients
,”
J. Orthop. Res.
,
34
(
7
), pp.
1234
1240
.10.1002/jor.23126
10.
Zhang
,
L.
,
Rehemutula
,
A.
,
Peng
,
F.
,
Yu
,
C.
,
Wang
,
T. B.
, and
Chen
,
L.
,
2015
, “
Does the Ratio of the Carpal Tunnel Inlet and Outlet Cross-Sectional Areas in the Median Nerve Reflect Carpal Tunnel Syndrome Severity?
,”
Neural Regener. Res.
,
10
(
7
), pp.
1172
1176
.10.4103/1673-5374.160117
11.
Csillik
,
A.
,
Bereczki
,
D.
,
Bora
,
L.
, and
Arányi
,
Z.
,
2016
, “
The Significance of Ultrasonographic Carpal Tunnel Outlet Measurements in the Diagnosis of Carpal Tunnel Syndrome
,”
Clin. Neurophysiol.
,
127
(
12
), pp.
3516
3523
.10.1016/j.clinph.2016.09.015
12.
Hunderfund
,
A.
,
Boon
,
A.
,
Mandrekar
,
J.
, and
Sorenson
,
E.
,
2011
, “
Sonography in Carpal Tunnel Syndrome
,”
Muscle Nerve
,
44
(
4
), pp.
485
491
.10.1002/mus.22075
13.
Bathala
,
L.
,
Kumar
,
P.
,
Kumar
,
K.
,
Shaik
,
A.
, and
Visser
,
L.
,
2014
, “
Normal Values of Median Nerve Cross-Sectional Area Obtained by Ultrasound Along Its Course in the Arm With Electrophysiological Correlations, in 100 Asian Subjects
,”
Muscle Nerve
,
49
(
2
), pp.
284
286
.10.1002/mus.23912
14.
Fisse
,
A.
,
Katsanos
,
A.
,
Gold
,
R.
,
Pitarokoili
,
K.
, and
Krogias
,
C.
,
2021
, “
Cross-Sectional Area Reference Values for Peripheral Nerve Ultrasound in Adults: A Systematic Review and Meta-Analysis—Part I: Upper Extremity Nerves
,”
Eur. J. Neurol.
,
28
(
5
), pp.
1684
1691
.10.1111/ene.14759
15.
Mogk
,
J.
, and
Keir
,
P.
,
2007
, “
Evaluation of the Carpal Tunnel Based on 3-D Reconstruction From MRI
,”
J. Biomech.
,
40
(
10
), pp.
2222
2229
.10.1016/j.jbiomech.2006.10.033
16.
Shah
,
R.
, and
Li
,
Z. M.
,
2022
, “
Three-Dimensional Carpal Arch Morphology Using Robot-Assisted Ultrasonography
,”
IEEE Trans. Biomed. Eng.
,
69
(
2
), pp.
894
898
.10.1109/TBME.2021.3108720
17.
Koo
,
T.
, and
Li
,
M.
,
2016
, “
A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research
,”
J. Chiropractic Med.
,
15
(
2
), pp.
155
163
.10.1016/j.jcm.2016.02.012
18.
Shah
,
R.
, and
Li
,
Z. M.
,
2020
, “
Ligament and Bone Arch Partition of the Carpal Tunnel by Three-Dimensional Ultrasonography
,”
ASME J. Biomech. Eng.
,
142
(
9
), p.
091008
.10.1115/1.4046502
19.
Katayama
,
K.
,
Shibata
,
K.
,
Sasaki
,
T.
,
Osada
,
R.
, and
Horita
,
Y.
,
2018
, “
Development of Probe Control System and Median Nerve Extraction in Ultrasound Images for 3D Visualization
,”
Electron. Commun. Jpn.
,
101
(
11
), pp.
3
12
.10.1002/ecj.12110
20.
Funahashi
,
T.
,
Suzuki
,
T.
,
Hayakawa
,
K.
,
Nakane
,
T.
,
Maeda
,
A.
,
Kuroiwa
,
T.
,
Kawano
,
Y.
,
Iwamoto
,
T.
, and
Fujita
,
N.
,
2022
, “
Visualization of the Morphological Changes in the Median Nerve After Carpal Tunnel Release Using Three-Dimensional Magnetic Resonance Imaging
,”
Eur. Radiol.
,
32
(
5
), pp.
3016
3023
.10.1007/s00330-021-08447-y
21.
Sun
,
K.
,
Zhang
,
J.
,
Chen
,
T.
,
Chen
,
Z.
,
Chen
,
Z.
,
Li
,
Z.
,
Li
,
H.
, and
Hu
,
P.
,
2009
, “
Three-Dimensional Reconstruction and Visualization of the Median Nerve From Serial Tissue Sections
,”
Microsurgery
,
29
(
7
), pp.
573
577
.10.1002/micr.20646
22.
Lakshminarayanan
,
K.
,
Shah
,
R.
, and
Li
,
Z.-M.
,
2020
, “
Morphological and Positional Changes of the Carpal Arch and Median Nerve Associated With Wrist Deviations
,”
Clin. Biomech.
,
71
, pp.
133
138
.10.1016/j.clinbiomech.2019.10.024
23.
van Doesburg
,
M.
,
Henderson
,
J.
,
van der Molen
,
A.
,
An
,
K. N.
, and
Amadio
,
P.
,
2012
, “
Transverse Plane Tendon and Median Nerve Motion in the Carpal Tunnel: Ultrasound Comparison of Carpal Tunnel Syndrome Patients and Healthy Volunteers
,”
PLoS One
,
7
(
5
), p.
e37081
.10.1371/journal.pone.0037081
24.
Pacek
,
C.
,
Tang
,
J.
,
Goitz
,
R.
,
Kaufmann
,
R.
, and
Li
,
Z. M.
,
2010
, “
Morphological Analysis of the Carpal Tunnel
,”
Hand
,
5
(
1
), pp.
77
81
.10.1007/s11552-009-9220-9
25.
Cobb
,
T.
,
Dalley
,
B.
,
Posteraro
,
R.
, and
Lewis
,
R.
,
1993
, “
Anatomy of the Flexor Retinaculum
,”
J. Hand Surg.
,
18
(
1
), pp.
91
99
.10.1016/0363-5023(93)90251-W
26.
Sanmugalingam
,
N.
,
Rault
,
M.
, and
Toms
,
A.
,
2020
, “
Normal Variations in Position and Relations of the Median Nerve in the Carpal Tunnel: A Cross-Sectional Observational Study Using Clinical Magnetic Resonance Imaging
,”
Clin. Anat.
,
33
(
4
), pp.
598
604
.10.1002/ca.23458
27.
Wang
,
Y.
,
Zhao
,
C.
,
Passe
,
S.
,
Filius
,
A.
,
Thoreson
,
A.
,
An
,
K. N.
, and
Amadio
,
P.
,
2014
, “
Transverse Ultrasound Assessment of Median Nerve Deformation and Displacement in the Human Carpal Tunnel During Wrist Movements
,”
Ultrasound Med. Biol.
,
40
(
1
), pp.
53
61
.10.1016/j.ultrasmedbio.2013.09.009
28.
Kang
,
H.
, and
Shik Yoon
,
J.
,
2016
, “
Effect of Finger Motion on Transverse Median Nerve Movement in the Carpal Tunnel
,”
Muscle Nerve
,
54
(
4
), pp.
738
742
.10.1002/mus.25101
29.
Goetz
,
J.
,
Thedens
,
D.
,
Kunze
,
N.
,
Lawler
,
E.
, and
Brown
,
T.
,
2010
, “
Day-to-Day Variability of Median Nerve Location Within the Carpal Tunnel
,”
Clin. Biomech.
,
25
(
7
), pp.
660
665
.10.1016/j.clinbiomech.2010.04.009
30.
Kim
,
H.
,
Joo
,
S.
,
Cho
,
H.
, and
Kim
,
Y.
,
2013
, “
Comparison of Proximal and Distal Cross-Sectional Areas of the Median Nerve, Carpal Tunnel, and Nerve/Tunnel Index in Subjects With Carpal Tunnel Syndrome
,”
Arch. Phys. Med. Rehabil.
,
94
(
11
), pp.
2151
2156
.10.1016/j.apmr.2013.05.008
31.
Korstanje
,
J. W.
,
Balen
,
R.
,
Boer
,
M.
,
Blok
,
J.
,
Slijper
,
H.
,
Stam
,
H.
,
Hovius
,
S.
, and
Selles
,
R.
,
2013
, “
Assessment of Transverse Ultrasonographic Parameters to Optimize Carpal Tunnel Syndrome Diagnosis in a Case-Control Study
,”
Muscle Nerve
,
48
(
4
), pp.
532
538
.10.1002/mus.23788
You do not currently have access to this content.