Osteoarthritis sufferers commonly have first metatarsophalangeal joint (MTPJ) problems in which articular surfaces are changed permanently due to fatigue. Therefore, medical devices for early diagnosis would increase the opportunity for prevention of disease progression. In previous studies on stiffness of the first MTPJ many details, although functionally of great importance, have not been fully considered including: design and size of the device, tribology consideration, and errors from device. Therefore, the motivation of our research was to enhance the device design by reducing the size of the device, and device design was enhanced by minimizing measurement errors through development of a new ergonomic left and right foot instrument located medial to the first MTPJ (instead of beneath the foot). The first MTPJ stiffness (N mm/kg radian) measurement was taken on 28 subjects with two replicates per subject by the same tester. The first MTPJ stiffness ranged from 3.49 to 14.42 N mm/kg radian with the mean (SD) value of 8.28 (3.15) N mm/kg radian for the left feet and 3.91 to 11.90 N mm/kg radian with the mean (SD) value of 7.65 (2.07) N mm/kg radian for the right feet. Reliability evaluation was measured using intraclass correlation coefficient and described an excellent reliability between two tests.

References

1.
Vanore
,
J. V.
,
Christensen
,
J. C.
,
Kravitz
,
S. R.
,
Schuberth
,
J. M.
,
Thomas
,
J. L.
,
Weil
,
L. S.
,
Zlotoff
,
H. J.
, and
Couture
,
S. D.
,
2003
, “
Diagnosis and Treatment of First Metatarsophalangeal Joint Disorders. Section 1: Hallux Valgus
,”
J. Foot Ankle Surg.
,
42
(
3
), pp.
112
123
.
2.
Gu
,
Y.-T.
,
Chen
,
J.
,
Meng
,
Z.-L.
,
Ge
,
W.-Y.
,
Bian
,
Y.-Y.
,
Cheng
,
S.-W.
,
Xing
,
C.-K.
,
Yao
,
J.-L.
,
Fu
,
J.
, and
Peng
,
L.
,
2017
, “
Research Progress on Osteoarthritis Treatment Mechanisms
,”
Biomed. Pharmacother.
,
93
(
Suppl. C
), pp.
1246
1252
.
3.
Nix
,
S.
,
Smith
,
M.
, and
Vicenzino
,
B.
,
2010
, “
Prevalence of Hallux Valgus in the General Population: A Systematic Review and Meta-Analysis
,”
J. Foot Ankle Res.
,
3
(
1
), p.
21
.
4.
Tomanik
,
M.
,
Nikodem
,
A.
, and
Filipiak
,
J.
,
2016
, “
Microhardness of Human Cancellous Bone Tissue in Progressive Hip Osteoarthritis
,”
J. Mech. Behav. Biomed. Mater.
,
64
(
Suppl. C
), pp.
86
93
.
5.
Iolascon
,
G.
,
Gimigliano
,
F.
,
Moretti
,
A.
,
de Sire
,
A.
,
Migliore
,
A.
,
Brandi
,
M. L.
, and
Piscitelli
,
P.
,
2017
, “
Early Osteoarthritis: How to Define, Diagnose, and Manage: A Systematic Review
,”
Eur. Geriatr. Med.
,
8
(
5–6
), pp.
383
396
.
6.
Heng
,
M. L.
,
Chua
,
Y. K.
,
Pek
,
H. K.
,
Krishnasamy
,
P.
, and
Kong
,
P. W.
,
2016
, “
A Novel Method of Measuring Passive Quasi-Stiffness in the First Metatarsophalangeal Joint
,”
J. Foot Ankle Res.
,
9
(
1
), p.
41
.
7.
Cody
,
E. A.
,
Kraszewski
,
A. P.
,
Marinescu
,
A.
,
Kunas
,
G. C.
,
Mani
,
S. B.
,
Rao
,
S.
,
Hillstrom
,
H. H.
, and
Ellis
,
S. J.
,
2017
, “
Measuring Joint Flexibility in Hallux Rigidus Using a Novel Flexibility Jig
,”
Foot Ankle Int.
,
38
(
8
), pp.
885
892
.
8.
Man
,
H.-S.
,
Leung
,
A. K.-L.
,
Cheung
,
J. T.-M.
, and
Sterzing
,
T.
,
2016
, “
Reliability of Metatarsophalangeal and Ankle Joint Torque Measurements by an Innovative Device
,”
Gait Posture
,
48
, pp.
189
193
.
9.
Creighton
,
D.
, and
Olson
,
V. L.
,
1987
, “
Evaluation of Range of Motion of the First Metatarsophalangeal Joint in Runners With Plantar Faciitis*
,”
J. Orthop. Sports Phys. Ther.
,
8
(
7
), pp.
357
361
.
10.
Clarkson
,
D. M.
,
2017
, “
Medical Device Guidebook: A Browser Information Resource for Medical Device Users
,”
Med. Eng. Phys.
,
41
(
Suppl. C
), pp.
97
102
.
11.
Shapiro
,
S. S.
, and
Wilk
,
M. B.
,
1965
, “
An Analysis of Variance Test for Normality (Complete Samples)
,”
Biometrika
,
52
(
3/4
), pp.
591
611
.
12.
Shrout
,
P. E.
, and
Fleiss
,
J. L.
,
1979
, “
Intraclass Correlations: Uses in Assessing Rater Reliability
,”
Psychol. Bull.
,
86
(
2
), p.
420
.
13.
Sheng
,
Y.
, and
Sheng
,
Z.
,
2012
, “
Is Coefficient Alpha Robust to Non-Normal Data?
,”
Front. Psychol.
,
3
, p.
34
.
14.
Jacobson
,
B.
, and
Murray
,
A.
,
2007
,
Medical Devices: Use and Safety
,
Elsevier Health Sciences
, Amsterdam, The Netherlands.
15.
Shereff
,
M. J.
,
Bejjani
,
F. J.
, and
Kummer
,
F. J.
,
1986
, “
Kinematics of the First Metatarsophalangeal Joint
,”
J. Bone Jt. Surg. Am.
,
68
(
3
), pp.
392
398
.
16.
Sharples
,
S.
,
Martin
,
J.
,
Lang
,
A.
,
Craven
,
M.
,
O'Neill
,
S.
, and
Barnett
,
J.
,
2012
, “
Medical Device Design in Context: A Model of User–Device Interaction and Consequences
,”
Displays
,
33
(
4–5
), pp.
221
232
.
17.
Shah
,
S. G. S.
, and
Robinson
,
I.
,
1990
, “
Medical Device Technologies: Who is the User?
,”
Int. J. Healthcare Technol. Manage.
,
9
(
2
), pp.
181
197
.
18.
Fratzl
,
P.
,
2008
,
Collagen: Structure and Mechanics, an Introduction
,
Springer
, Berlin, pp.
1
13
.
19.
Bandy
,
W. D.
, and
Sanders
,
B.
,
2007
,
Therapeutic Exercise for Physical Therapist Assistants
,
Lippincott Williams & Wilkins
, Philadelphia, PA.
20.
Zachazewski
,
J.
,
1990
, “
Flexibility for Sports
,”
Sports Physical Therapy
,
Appleton & Lange
,
Norwalk, CT
.
21.
Wright
,
V.
, and
Johns
,
R. J.
,
1961
, “
Quantitative and Qualitative Analysis of Joint Stiffness in Normal Subjects and in Patients With Connective Tissue Diseases
,”
Ann. Rheum. Dis.
,
20
(
1
), pp.
36
46
.
22.
Ab Rahman
,
J.
,
2015
,
Brief Guidelines for Methods and Statistics in Medical Research
,
Springer
, Berlin.
23.
Watkins, J., 2009,
Pocket Podiatry: Functional Anatomy
, Elsevier Health Sciences, Amsterdam, The Netherlands.
24.
Mickle
,
K. J.
,
Munro
,
B. J.
,
Lord
,
S. R.
,
Menz
,
H. B.
, and
Steele
,
J. R.
, 2011, “
Soft Tissue Thickness Under the Metatarsal Heads is Reduced in Older People With Toe Deformities
,”
J. Orthop. Res.
,
29
(7), pp. 1042–1046.https://onlinelibrary.wiley.com/doi/pdf/10.1002/jor.21328
25.
Kelikian
,
A. S.
, and
Sarrafian
,
S. K.
, 2011,
Sarrafian's Anatomy of the Foot and A: Descriptive, Topographic, Functional
, Lippincott Williams & Wilkins, Philadelphia, PA.
You do not currently have access to this content.