Advanced prosthetic knees for transfemoral amputees are currently based on controlled damper mechanisms. Such devices require little energy to operate, but can only produce negative or zero joint power, while normal knee joint function requires alternative phases of positive and negative work. The inability to generate positive work may limit the user’s functional capabilities, may cause undesirable adaptive behavior, and may contribute to excessive metabolic energy cost for locomotion. In order to overcome these problems, we present a novel concept for an energy-storing prosthetic knee, consisting of a rotary hydraulic actuator, two valves, and a spring-loaded hydraulic accumulator. In this paper, performance of the proposed device will be assessed by computational modeling and by simulation of functional activities. A computational model of the hydraulic system was developed, with methods to obtain optimal valve control patterns for any given activity. The objective function for optimal control was based on tracking of joint angles, tracking of joint moments, and the energy cost of operating the valves. Optimal control solutions were obtained, based on data collected from three subjects during walking, running, and a sit-stand-sit cycle. Optimal control simulations showed that the proposed device allows near-normal knee function during all three activities, provided that the accumulator stiffness was tuned to each activity. When the energy storage mechanism was turned off in the simulations, the system functioned as a controlled damper device and optimal control results were similar to literature data on human performance with such devices. When the accumulator stiffness was tuned to walking, simulated performance for the other activities was sub-optimal but still better than with a controlled damper. We conclude that the energy-storing knee concept is valid for the three activities studied, that modeling and optimal control can assist the design process, and that further studies using human subjects are justified.
Skip Nav Destination
Article navigation
Research Papers
Modeling and Optimal Control of an Energy-Storing Prosthetic Knee
Antonie J. van den Bogert,
bogert@orchardkinetics.com
Antonie J. van den Bogert
Orchard Kinetics
, Cleveland, OH
Search for other works by this author on:
Sergey Samorezov,
Sergey Samorezov
Department of Biomedical Engineering
, Cleveland Clinic, Cleveland, OH
Search for other works by this author on:
Brian L. Davis,
Brian L. Davis
Austen BioInnovation Institute
, Akron, OH
Search for other works by this author on:
William A. Smith
William A. Smith
Department of Biomedical Engineering
, Cleveland Clinic, Cleveland, OH
Search for other works by this author on:
Antonie J. van den Bogert
Sergey Samorezov
Department of Biomedical Engineering
, Cleveland Clinic, Cleveland, OH
Brian L. Davis
Austen BioInnovation Institute
, Akron, OH
William A. Smith
Department of Biomedical Engineering
, Cleveland Clinic, Cleveland, OH
J Biomech Eng. May 2012, 134(5): 051007 (8 pages)
Published Online: June 5, 2012
Article history
Received:
June 21, 2011
Revised:
March 26, 2012
Posted:
May 1, 2012
Published:
June 5, 2012
Online:
June 5, 2012
Citation
van den Bogert, A. J., Samorezov, S., Davis, B. L., and Smith, W. A. (June 5, 2012). "Modeling and Optimal Control of an Energy-Storing Prosthetic Knee." ASME. J Biomech Eng. May 2012; 134(5): 051007. https://doi.org/10.1115/1.4006680
Download citation file:
Get Email Alerts
Cited By
Bone Remodeling Around Solid and Porous Interbody Cages in the Lumbar Spine
J Biomech Eng (October 2022)
A Computational Framework for Atrioventricular Valve Modeling Using Open-Source Software
J Biomech Eng (October 2022)
In Vitro Biomechanics of the Cervical Spine: A Systematic Review
J Biomech Eng (October 2022)
Related Articles
The Effects of the Inertial Properties of Above-Knee Prostheses on Optimal Stiffness, Damping, and Engagement Parameters of Passive Prosthetic Knees
J Biomech Eng (December,2016)
Determination of Optimal Counter-Mass Location in Active Prostheses for Transfemoral Amputees to Replicate Sound Limb Swing
J. Med. Devices (December,2014)
Design of a Four-Bar Latch Mechanism and a Shear-Based Rotary Viscous Damper for Single-Axis Prosthetic Knees
J. Mechanisms Robotics (June,2022)
The Design and Initial Experimental Validation of an Active Myoelectric Transfemoral Prosthesis
J. Med. Devices (March,2012)
Related Proceedings Papers
Related Chapters
Key Components of Liquid Cooled Systems
Thermal Design of Liquid Cooled Microelectronic Equipment
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
QP Based Encoder Feedback Control
Robot Manipulator Redundancy Resolution