In the past decade, novel tools for surgical planning and disease diagnosis have been developed to detect the liver’s mechanical properties. Some tools utilize superficial indentation type measurements to determine the elasticity of the liver parenchyma and to assume material homogeneity. In fact, the liver is a soft tissue covered with a connective sheathing that is called Glisson’s capsule. This article quantifies the effect of this capsule on the measured or “effective” elastic modulus obtained by indentation with a spherical geometry. Two sets of parametric computational studies in which the Glisson capsule thickness and elasticity were varied, demonstrated the relationship between the measured elastic response and the underlying parenchymal elastic response. Previously reported in vivo indentation data on the human liver were utilized to determine the elasticity of its parenchyma. The results indicated a linear relationship between the effective (measured) elastic response and the underlying parenchyma for the Glisson capsule thicknesses considered. When previously published human liver indentation data were analyzed, the measured elastic modulus was nearly 6.9% greater than the underlying parenchyma elastic modulus. Although the analyzed data were obtained from a single liver and yet displayed a significant variation, the Glisson capsule elasticity induced a significant but systematic error as well. The Glisson capsule thickness error was negligible for capsule parameters associated with a normal liver. Based on this work, an emphasis on the Glisson capsule’s contribution to the mechanical response of the liver would enhance the clinical potential of indentation-based novel tools for liver care.

1.
Foucher
,
J.
,
Chanteloup
,
E.
,
Vergniol
,
J.
,
Castera
,
L.
,
Le Bail
,
B.
,
Adhoute
,
X.
,
Bertet
,
P.
,
Couzigou
,
P.
, and
De Ledinghen
,
V.
, 2006, “
Diagnosis of Cirrhosis by Transient Elastography (FibroScan): A Prospective Study
,”
Gut
0017-5749,
55
(
3
), pp.
403
408
.
2.
Roulot
,
D.
,
Czernichow
,
S.
,
Le Clesiau
,
H.
,
Costes
,
J. -L.
,
Vergnaud
,
A. -C.
, and
Beaugrand
,
M.
, 2008, “
Liver Stiffness Values in Apparently Healthy Subjects: Influence of Gender and Metabolic Syndrome
,”
J. Hepatol
0168-8278,
48
(
4
), pp.
606
613
.
3.
Rouviere
,
O.
,
Yin
,
M.
,
Dresner
,
M. A.
,
Rossman
,
P. J.
,
Burgart
,
L. J.
,
Fidler
,
J. L.
, and
Ehman
,
R. L.
, 2006, “
MR Elastography of the Liver: Preliminary Results
,”
Radiology
0033-8419,
240
(
2
), pp.
440
448
.
4.
Venkatesh
,
S. K.
,
Yin
,
M.
,
Glockner
,
J. F.
,
Takahashi
,
N.
,
Araoz
,
P. A.
,
Talwalkar
,
J. A.
, and
Ehman
,
R. L.
, 2008, “
MR Elastography of Liver Tumors: Preliminary Results
,”
AJR, Am. J. Roentgenol.
0361-803X,
190
(
6
), pp.
1534
1540
.
5.
Camarillo
,
D. B.
,
Krummel
,
T. M.
, and
Salisbury
,
J. K.
, 2004, “
Robotic Technology in Surgery: Past, Present, and Future
,”
Am. J. Surg.
0002-9610,
188
, pp.
2
15
.
6.
Gutt
,
C. N.
,
Oniu
,
T.
,
Mehrabi
,
A.
,
Kashfi
,
A.
,
Schemmer
,
P.
, and
Buchler
,
M. W.
, 2004, “
Robot-Assisted Abdominal Surgery
,”
Br. J. Surg.
0007-1323,
91
, pp.
1390
1397
.
7.
Hanly
,
E. J.
, and
Talamini
,
M. A.
, 2004, “
Robotic Abdominal Surgery
,”
Am. J. Surg.
0002-9610,
188
, pp.
19
26
.
8.
Nguyen
,
N. T.
,
Hinojosa
,
M. W.
,
Finley
,
D.
,
Stevens
,
M.
, and
Paya
,
M.
, 2004, Application of Robotics in General Surgery: Initial Experience.
9.
Holbrook
,
T. L.
,
Hoyt
,
D. B.
,
Eastman
,
A. B.
,
Sise
,
M. J.
,
Kennedy
,
F.
,
Velky
,
T.
,
Conroy
,
C.
,
Pacyna
,
S.
, and
Erwin
,
S.
, 2007, “
The Impact of Safety Belt Use on Liver Injuries in Motor Vehicle Crashes: The Importance of Motor Vehicle Safety Systems
,”
J. Trauma
0022-5282,
63
(
2
), pp.
300
306
.
10.
Chui
,
C.
,
Kobayashi
,
E.
,
Chen
,
X.
,
Hisada
,
T.
, and
Sakuma
,
I.
, 2004, “
Combined Compression and Elongation Experiments and Non-Linear Modelling of Liver Tissue for Surgical Simulation
,”
Med. Biol. Eng. Comput.
0140-0118,
42
, pp.
787
798
.
11.
Miller
,
K.
, 2000, “
Constitutive Modelling of Abdominal Organs
,”
J. Biomech.
0021-9290,
33
, pp.
367
373
.
12.
Roan
,
E.
, and
Vemaganti
,
K.
, 2007, “
The Nonlinear Material Properties of the Liver Tissue Determined From No-Slip Uniaxial Compression Experiments
,”
J. Biomech. Eng.
0148-0731,
129
, pp.
450
456
.
13.
Carter
,
F. J.
,
Frank
,
T. G.
,
Davies
,
P. J.
,
McLean
,
D.
, and
Cuschieri
,
A.
, 2001, “
Measurements and Modelling of the Compliance of Human and Porcine Organs
,”
Med. Image Anal.
1361-8415,
5
, pp.
231
236
.
14.
Kerdok
,
A. E.
, and
Howe
,
R. D.
, 2005, “
A Physical Basis for a Two Time Constant Constitutive Model for Liver
,”
ASME Summer Bioengineering Conference
,
ASME
,
Vail, CO
.
15.
Hollenstein
,
M.
,
Nava
,
A.
,
Valtorta
,
D.
,
Snedeker
,
J.
, and
Mazza
,
E.
, 2006, “
Mechanical Characterization of the Liver Capsule and Parenchyma
,”
Lect. Notes Comput. Sci.
0302-9743,
4072
, pp.
150
158
.
16.
Chapman
,
G. B.
, and
Eagles
,
D. A.
, 2007, “
Ultrastructural Features of Glisson’s Capsule and the Overlying Mesothelium in Rat, Monkey and Pike Liver
,”
Tissue Cell
0040-8166,
39
(
5
), pp.
343
351
.
17.
Bataller
,
R.
, and
Brenner
,
D. A.
, 2005, “
Liver Fibrosis
,”
J. Clin. Invest.
0021-9738,
115
(
2
), pp.
209
218
.
18.
Castera
,
L.
,
Forns
,
X.
, and
Alberti
,
A.
, 2008, “
Non-Invasive Evaluation of Liver Fibrosis Using Transient Elastography
,”
J. Hepatol
0168-8278,
48
(
5
), pp.
835
847
.
19.
Coco
,
B.
,
Oliveri
,
F.
,
Malina
,
A. M.
,
Ciccorossi
,
P.
,
Sacco
,
R.
,
Colombatto
,
P.
,
Bonino
,
F.
, and
Brunetto
,
M. R.
, 2007, “
Transient Elastography: A New Surrogate Marker of Liver Fibrosis Influenced by Major Changes of Transaminases
,”
J. Viral Hepat.
1352-0504,
14
, pp.
360
369
.
20.
Yeh
,
W.
,
Li
,
P.
,
Jeng
,
Y.
,
Hsu
,
H.
,
Kuo
,
P.
,
Li
,
M.
,
Yang
,
P.
, and
Lee
,
P. H.
, 2002, “
Elastic Modulus Measurements of Human Liver and Correlation With Pathology
,”
Ultrasound Med. Biol.
0301-5629,
28
(
4
), pp.
467
474
.
21.
Yin
,
H. M.
,
Sun
,
L. Z.
,
Wang
,
G.
, and
Vannier
,
M. W.
, 2004, “
Modeling of Elastic Modulus Evolution of Cirrhotic Human Liver
,”
IEEE Trans. Biomed. Eng.
0018-9294,
51
(
10
), pp.
1854
1857
.
22.
Carter
,
T. J.
,
Sermesant
,
M.
,
Cash
,
D. M.
,
Barratt
,
D. C.
,
Tanner
,
C.
, and
Hawkes
,
D. J.
, 2005, “
Application of Soft Tissue Modelling to Image-Guided Surgery
,”
Med. Eng. Phys.
1350-4533,
27
(
10
), pp.
893
909
.
23.
Samur
,
E.
,
Sedef
,
M.
,
Basdogan
,
C.
,
Avtan
,
L.
, and
Düzgün
,
O.
, 2007, “
A Robotic Indenter for Minimally Invasive Measurement and Characterization of Soft Tissue Response
,”
Med. Image Anal.
1361-8415,
11
, pp.
361
373
.
24.
Nava
,
A.
,
Mazza
,
E.
,
Furrer
,
M.
,
Villiger
,
P.
, and
Reinhart
,
W. H.
, 2008, “
In Vivo Mechanical Characterization of Human Liver
,”
Med. Image Anal.
1361-8415,
12
(
2
), pp.
203
216
.
25.
Liu
,
H.
,
Noonan
,
D. P.
,
Althoefer
,
K.
, and
Seneviratne
,
L. D.
, 2008, “
Rolling Mechanical Imaging: A Novel Approach for Soft Tissue Modelling and Identification for Minimally Invasive Surgery
,”
IEEE International Conference on Robotics and Automation, IEEE Robotics and Automation Society
, pp.
845
850
.
26.
Arias
,
I. M.
,
Boyer
,
J. L.
,
Chisari
,
F. V.
,
Fausto
,
N.
,
Schachter
,
D.
, and
Shafritz
,
D. A.
, 2001,
The Liver Biology and Pathobiology
,
Lippincott Williams and Wilkins
,
Baltimore
.
27.
Ohtani
,
O.
, 1988, “
Three-Dimensional Organization of the Collagen Fibrillar Framework of the Human and Rat Livers
,”
Arch. Histol. Cytol.
0914-9465,
51
(
5
), pp.
473
488
.
28.
Bedossa
,
P.
, and
Carrat
,
F.
, 2009, “
Liver Biopsy: The Best, Not the Gold Standard
,”
J. Hepatol
0168-8278,
50
(
1
), pp.
1
3
.
29.
Ziol
,
M.
,
Handra-Luca
,
A.
,
Kettaneh
,
A.
,
Christidis
,
C.
,
Mal
,
F.
,
Kazemi
,
F.
,
De Ledinghen
,
V.
,
Marcellin
,
P.
,
Dhumeaux
,
D.
,
Trinchet
,
J. C.
, and
Beaugrand
,
M.
, 2005, “
Noninvasive Assessment of Liver Fibrosis by Measurement of Stiffness in Patients With Chronic Hepatitis C
,”
J. Hepatol
0168-8278,
41
, pp.
48
54
.
30.
Mazza
,
E.
,
Nava
,
A.
,
Hahnloser
,
D.
,
Jochum
,
W.
, and
Bajka
,
M.
, 2007, “
The Mechanical Response of Human Liver and Its Relation to Histology: An In Vivo Study
,”
Med. Image Anal.
1361-8415,
11
(
6
), pp.
663
672
.
31.
Schwartz
,
J. -M.
,
Denninger
,
M.
,
Rancourt
,
D.
,
Moisan
,
C.
, and
Laurendeau
,
D.
, 2005, “
Modelling Liver Tissue Properties Using a Non-Linear Visco-Elastic Model for Surgery Simulation
,”
Med. Image Anal.
1361-8415,
9
, pp.
103
112
.
32.
Jordan
,
P.
,
Socrate
,
S.
,
Zickler
,
T. E.
, and
Howe
,
R. D.
, 2009, “
Constitutive Modeling of Porcine Liver in Indentation Using 3D Ultrasound Imaging
,”
J. Mech. Behav. Biomed. Mater.
1751-6161,
2
(
2
), pp.
192
201
.
33.
Lin
,
D. C.
,
Dimitriadis
,
E. K.
, and
Horkay
,
F.
, 2007, “
Robust Strategies for Automated AFM Force Curve Analysis—II: Adhesion-Influenced Indentation of Soft, Elastic Materials
,”
ASME J. Biomech. Eng.
0148-0731,
129
(
6
), pp.
904
912
.
34.
Hertz
,
H.
, 1881, “
On the Contact of Elastic Solids
,”
J. Reine Angew. Math.
0075-4102,
92
, pp.
156
171
.
35.
Sneddon
,
I. N.
, 1965, “
The Relation Between Load and Penetration in the Axisymmetric Boussinesq Problem for a Punch of Arbitrary Profile
,”
Int. J. Eng. Sci.
0020-7225,
3
, pp.
47
57
.
36.
Groszmann
,
R. J.
,
Glickman
,
M.
,
Blei
,
A. T.
,
Storer
,
E.
, and
Conn
,
H. O.
, 1979, “
Wedged and Free Hepatic Venous Pressure Measured With a Balloon Catheter
,”
Gastroenterology
0016-5085,
76
(
2
), pp.
253
258
.
You do not currently have access to this content.