The relationships between the lengths of the ligaments and kinematics of the knee and quadriceps load, for low to physiologic levels of quadriceps loads, have not previously been studied. We investigated the effects of increasing levels of quadriceps force, necessary to balance increasing levels of externally applied flexion moments, on the kinematics of the tibiofemoral joint and on the separation distances between insertions of selected fibers of the major ligaments of the knee in twelve cadavera. Static measurements were made using a six-degree-of-freedom digitizer for flexion angles ranging from 0 to 120 deg in 15 deg increments. Quadriceps generated extension of the knee was performed by applying loads to the quadriceps tendon to equilibrate each of four magnitudes of external flexion moments equivalent to 8.33, 16.67, 25.00, and 33.33 percent of values previously reported for maximum isometric extension moments. The magnitude of quadriceps force increased linearly (p < 0.0001) as external flexion moment increased throughout the entire range of flexion. Anterior translation, internal rotation, and abduction of the tibia increased linearly (p < 0.0001, p < 0.001, p < 0.001) as external flexion moment and, hence, quadriceps load increased. For the fibers studied, the anterior cruciate ligament (p < 0.0076), posterior cruciate ligament (p < 0.0001), and medial collateral ligament (p < 0.0383) lengthened linearly while the lateral collateral ligament (p < 0.0124) shortened linearly as quadriceps load increased. Based on these results for low to physiologic levels of quadriceps loads, it is reasonable to assume that the ligament lengths or knee kinematics expected with higher quadriceps loads can be extrapolated.
Skip Nav Destination
Article navigation
December 1998
Research Papers
Increasing Quadriceps Loads Affect the Lengths of the Ligaments and the Kinematics of the Knee
Y.-F. Hsieh,
Y.-F. Hsieh
The University of Chicago, Section of Orthopædics and Rehabilitation Medicine, Department of Surgery, 5841 South Maryland Ave., MC 3079, Chicago, IL 60637
Search for other works by this author on:
L. F. Draganich
L. F. Draganich
The University of Chicago, Section of Orthopædics and Rehabilitation Medicine, Department of Surgery, 5841 South Maryland Ave., MC 3079, Chicago, IL 60637
Search for other works by this author on:
Y.-F. Hsieh
The University of Chicago, Section of Orthopædics and Rehabilitation Medicine, Department of Surgery, 5841 South Maryland Ave., MC 3079, Chicago, IL 60637
L. F. Draganich
The University of Chicago, Section of Orthopædics and Rehabilitation Medicine, Department of Surgery, 5841 South Maryland Ave., MC 3079, Chicago, IL 60637
J Biomech Eng. Dec 1998, 120(6): 750-756 (7 pages)
Published Online: December 1, 1998
Article history
Received:
March 17, 1997
Revised:
May 16, 1998
Online:
January 23, 2008
Citation
Hsieh, Y., and Draganich, L. F. (December 1, 1998). "Increasing Quadriceps Loads Affect the Lengths of the Ligaments and the Kinematics of the Knee." ASME. J Biomech Eng. December 1998; 120(6): 750–756. https://doi.org/10.1115/1.2834889
Download citation file:
Get Email Alerts
Cited By
Related Articles
Effect of ACL Deficiency on MCL Strains and Joint Kinematics
J Biomech Eng (June,2007)
Torsion and Bending Imposed on a New Anterior Cruciate Ligament Prosthesis During Knee Flexion: An Evaluation Method
J Biomech Eng (November,1984)
Development and Validation of a 3-D Model to Predict Knee Joint Loading During Dynamic Movement
J Biomech Eng (December,2003)
Recruitment of Knee Joint Ligaments
J Biomech Eng (February,1991)
Related Proceedings Papers
Related Chapters
The Effect of Anterior Cruciate Ligament Injury on Tibiofemoral Joint Biomechanics: Under Draw Load
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Creating and Eliminating Workplace Hazards by Design
An Instructional Aid For Occupational Safety and Health in Mechanical Engineering Design
Experimental results gained from the physiological response of GFP biosensors in scale-down conditions
GFP Whole Cell Microbial Biosensors: Scale-up and Scale-down Effects on Biopharmaceutical Processes