The Fontan operation is one in which the right heart is bypassed leaving the left ventricle to drive the blood through both the capillaries and the lungs, making it important to design an operation which is hemodynamically efficient. The object here was to relate the pressure in Fontan connections to its geometry with the aim of increasing the hemodynamically efficiency. From CT or magnetic resonance images, glass models were made of realistic atrio-pulmonary (AP) and cavo-pulmonary (CP) connections in which the right atrium and/or ventricle are bypassed. The glass models were connected to a steady flow loop and flow visualization, pressure and 3 component LDA measurements made. In the AP model the large atrium and curvature of the conduit created swirling patterns, the magnitude of which was similar to the axial velocity. This led to an inefficient flow and a subsequent large pressure loss (780 Pa). In contrast, the CP connection with a small intra-atrial chamber had reduced swirling and a significantly smaller pressure loss (400 Pa at 8 l.min) and was therefore a more efficient connection. There were, however, still pressure losses and it was found that these occurred where there was a large bending of the flow, such as from the superior vena cava to the MPA and from the MPA to the right pulmonary artery.
Skip Nav Destination
Article navigation
November 1995
Technical Papers
Hemodynamics of the Fontan Connection: An In-Vitro Study
Young H. Kim,
Young H. Kim
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
Search for other works by this author on:
P. G. Walker,
P. G. Walker
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
Search for other works by this author on:
A. A. Fontaine,
A. A. Fontaine
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
Search for other works by this author on:
S. Panchal,
S. Panchal
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
Search for other works by this author on:
A. E. Ensley,
A. E. Ensley
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
Search for other works by this author on:
J. Oshinski,
J. Oshinski
Egleston Children’s Hospital, Emory University, Atlanta, GA
Search for other works by this author on:
S. Sharma,
S. Sharma
Egleston Children’s Hospital, Emory University, Atlanta, GA
Search for other works by this author on:
B. Ha,
B. Ha
Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, N.C.
Search for other works by this author on:
C. L. Lucas,
C. L. Lucas
Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, N.C.
Search for other works by this author on:
A. P. Yoganathan
A. P. Yoganathan
Bioengineering Center, Georgia Institute of Technology, Atlanta, GA 30332-0405
Search for other works by this author on:
Young H. Kim
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
P. G. Walker
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
A. A. Fontaine
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
S. Panchal
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
A. E. Ensley
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100
J. Oshinski
Egleston Children’s Hospital, Emory University, Atlanta, GA
S. Sharma
Egleston Children’s Hospital, Emory University, Atlanta, GA
B. Ha
Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, N.C.
C. L. Lucas
Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, N.C.
A. P. Yoganathan
Bioengineering Center, Georgia Institute of Technology, Atlanta, GA 30332-0405
J Biomech Eng. Nov 1995, 117(4): 423-428 (6 pages)
Published Online: November 1, 1995
Article history
Received:
May 17, 1994
Revised:
October 19, 1994
Online:
October 30, 2007
Citation
Kim, Y. H., Walker, P. G., Fontaine, A. A., Panchal, S., Ensley, A. E., Oshinski, J., Sharma, S., Ha, B., Lucas, C. L., and Yoganathan, A. P. (November 1, 1995). "Hemodynamics of the Fontan Connection: An In-Vitro Study." ASME. J Biomech Eng. November 1995; 117(4): 423–428. https://doi.org/10.1115/1.2794203
Download citation file:
Get Email Alerts
Related Articles
A Computational Pulsatile Model of the Bidirectional Cavopulmonary Anastomosis: The Influence of Pulmonary Forward Flow
J Biomech Eng (November,1996)
Distribution of Hepatic Venous Blood in the Total Cavo Pulmonary Connection: An In Vitro Study Into the Effects of Connection Geometry
J Biomech Eng (December,2001)
The Role of Collagen Synthesis in Ventricular and Vascular Adaptation to Hypoxic Pulmonary Hypertension
J Biomech Eng (February,2013)
Hemodynamics Characteristics of a Four-Way Right-Atrium Bypass Connector
J. Fluids Eng (December,2018)
Related Proceedings Papers
Related Chapters
Health and Safety and Emergency Response
Pipeline Transportation of Carbon Dioxide Containing Impurities
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices