The glenohumeral joint is frequently dislocated causing injury to the glenohumeral capsule (axillary pouch (AP), anterior band of the inferior glenohumeral ligament (AB-IGHL), posterior band of the inferior glenohumeral ligament (PB-IGHL), posterior (Post), and anterosuperior region (AS)). [1, 2] The capsule is a passive stabilizer to the glenohumeral joint and primarily functions to resist dislocation during extreme ranges of motion. [3] When unloaded, the capsule consists of randomly oriented collagen fibers, which play a pertinent role in its function to resist loading in multiple directions. [4] The location of failure in only the axillary pouch has been shown to correspond with the highest degree of collagen fiber orientation and maximum principle strain just prior to failure. [4, 5] However, several discrepancies were found when comparing the collagen fiber alignment between the AB-IGHL, AP, and PB-IGHL. [3,6,7] Therefore, the objective was to determine the collagen fiber alignment and maximum principal strain in five regions of the capsule during uniaxial extension to failure and to determine if these parameters could predict the location of tissue failure. Since the capsule functions as a continuous sheet, we hypothesized that maximum principal strain and peak collagen fiber alignment would correspond with the location of tissue failure in all regions of the glenohumeral capsule.
Skip Nav Destination
ASME 2011 Summer Bioengineering Conference
June 22–25, 2011
Farmington, Pennsylvania, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-5458-7
PROCEEDINGS PAPER
Collagen Fiber Alignment and Maximum Principal Strain in the Glenohumeral Capsule Predict Location of Failure During Uniaxial Extension
Kelvin Luu,
Kelvin Luu
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Carrie A. Voycheck,
Carrie A. Voycheck
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Patrick J. McMahon,
Patrick J. McMahon
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Richard E. Debski
Richard E. Debski
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Kelvin Luu
University of Pittsburgh, Pittsburgh, PA
Carrie A. Voycheck
University of Pittsburgh, Pittsburgh, PA
Patrick J. McMahon
University of Pittsburgh, Pittsburgh, PA
Richard E. Debski
University of Pittsburgh, Pittsburgh, PA
Paper No:
SBC2011-53492, pp. 903-904; 2 pages
Published Online:
July 17, 2013
Citation
Luu, K, Voycheck, CA, McMahon, PJ, & Debski, RE. "Collagen Fiber Alignment and Maximum Principal Strain in the Glenohumeral Capsule Predict Location of Failure During Uniaxial Extension." Proceedings of the ASME 2011 Summer Bioengineering Conference. ASME 2011 Summer Bioengineering Conference, Parts A and B. Farmington, Pennsylvania, USA. June 22–25, 2011. pp. 903-904. ASME. https://doi.org/10.1115/SBC2011-53492
Download citation file:
4
Views
0
Citations
Related Proceedings Papers
Related Articles
Thermal Therapy in Urologic Systems: A Comparison of Arrhenius and Thermal Isoeffective Dose Models in Predicting Hyperthermic Injury
J Biomech Eng (July,2009)
Simulation of Soft Tissue Failure Using the Material Point Method
J Biomech Eng (December,2006)
The Impact of Glenoid Labrum Thickness and Modulus on Labrum and Glenohumeral Capsule Function
J Biomech Eng (December,2010)
Related Chapters
Experimental Research on Fiber Grating Sensor Acoustic Emission Detection of Rock Material Specimen Failure
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)
Role of Dislocation Patterns on Hydrogen Trapping in Deformed Pure Nickel: A TDMS Analysis
International Hydrogen Conference (IHC 2012): Hydrogen-Materials Interactions
Hydrogen Enhanced Dislocation Emission at a Crack Tip
International Hydrogen Conference (IHC 2012): Hydrogen-Materials Interactions