Abstract
Results of a study on flow boiling heat transfer enhancement of kerosene with ribbed tube (rib pitch 9 mm, rib height 0.4 ∼ 0.6 mm, rib width 3.9 mm) are reported. Experiments of upward flow boiling heat transfer in smooth tube and ribbed tube at a pressure 2 bar were performed for a range of heat flux (28.5 ∼ 93.75 kW/m2), mass flux (410 ∼ 810 kg/m2 s) and equilibrium mass quality (0 ∼ 0.3) respectively. Heat transfer coefficients in the ribbed tube are improved by a factor of 1.4 ∼ 1.6 as compared with the smooth tube. A correlation of flow boiling heat transfer coefficients is proposed for the enhanced ribbed tube. Phenomenon and mechanism of flow boiling heat transfer with kerosene are discussed.
Volume Subject Area:
Boiling Heat Transfer
This content is only available via PDF.
Copyright © 1997 by The American Society of Mechanical Engineers
You do not currently have access to this content.