The intravenous fluid of choice for acute blood volume replacement remains controversial. We focus here on the two hydroxyethyl (HES) available in Canada: HES 130/0.40 (Voluven®) and HES 260/0.45 (Pentaspan®). Although information regarding their pharmacokinetic and risk/benefit profiles are available, how the infusion of these fluids could affect blood viscosity and vascular endothelial function in humans is largely unknown. Dynamic viscosity was measured at 21°C and 37°C through capillary viscometry. The HES solutions were driven through a closed flow loop at room temperature (21°C). Viscosity at 21°C was 7.62 centipoise (cP) for HES 260/0.45 and 2.73 cP for HES 130/0.40 decreasing to 4.23 cP for HES 260/0.45 and 1.72 cP for HES 130/0.40 at 37°C. Analysis of viscous behaviour through pipe flow found that HES 260/0.45 displayed marginal variations in viscosity suggesting Newtonian behaviour across our range of Re measured. HES 130/0.40 displayed an appreciable increase in viscosity at higher Re suggesting the presence of shear thickening behaviour. Human aortic endothelial cells (HAEC) and human microvascular endothelial cells (HMVEC) were exposed to the HES solutions and saline to identify chemical effects on vascular endothelium. Western blot quantification showed that E-selectin was the leukocyte adhesion receptor that was most strongly affected, and this was not dose dependent. Interestingly, HAEC and HMVEC had different responses to HES treatment, suggesting that different vascular tissues may have different outcomes to HES infusion. Protein expression in HMVEC decreased when exposed to both HES solutions.
Skip Nav Destination
ASME 2010 International Mechanical Engineering Congress and Exposition
November 12–18, 2010
Vancouver, British Columbia, Canada
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4426-7
PROCEEDINGS PAPER
Effects of Starch Volume Expanders on Blood Viscosity and Vascular Endothelial Markers
Andrew M. Walker,
Andrew M. Walker
University of Calgary, Calgary, AB, Canada
Search for other works by this author on:
Kogan Lee,
Kogan Lee
University of Calgary, Calgary, AB, Canada
Search for other works by this author on:
Kristina D. Rinker,
Kristina D. Rinker
University of Calgary, Calgary, AB, Canada
Search for other works by this author on:
Robert D. Shepherd,
Robert D. Shepherd
University of Calgary, Calgary, AB, Canada
Search for other works by this author on:
Gary M. Dobson,
Gary M. Dobson
University of Calgary, Calgary, AB, Canada
Search for other works by this author on:
Clifton R. Johnston
Clifton R. Johnston
University of Calgary, Calgary, AB, Canada
Search for other works by this author on:
Andrew M. Walker
University of Calgary, Calgary, AB, Canada
Kogan Lee
University of Calgary, Calgary, AB, Canada
Kristina D. Rinker
University of Calgary, Calgary, AB, Canada
Robert D. Shepherd
University of Calgary, Calgary, AB, Canada
Gary M. Dobson
University of Calgary, Calgary, AB, Canada
Clifton R. Johnston
University of Calgary, Calgary, AB, Canada
Paper No:
IMECE2010-40628, pp. 253-261; 9 pages
Published Online:
April 30, 2012
Citation
Walker, AM, Lee, K, Rinker, KD, Shepherd, RD, Dobson, GM, & Johnston, CR. "Effects of Starch Volume Expanders on Blood Viscosity and Vascular Endothelial Markers." Proceedings of the ASME 2010 International Mechanical Engineering Congress and Exposition. Volume 2: Biomedical and Biotechnology Engineering. Vancouver, British Columbia, Canada. November 12–18, 2010. pp. 253-261. ASME. https://doi.org/10.1115/IMECE2010-40628
Download citation file:
9
Views
Related Proceedings Papers
Related Articles
Influence of Cell Deformation on Leukocyte Rolling Adhesion in Shear Flow
J Biomech Eng (December,1999)
Blood Flow in Small Curved Tubes
J Biomech Eng (December,2003)
Measuring the Mechanical Properties of Individual Human Blood Cells
J Biomech Eng (November,1993)
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices
Characterization and evaluation
Biocompatible Nanomaterials for Targeted and Controlled Delivery of Biomacromolecules