Miniscrew implants have seen increasing clinical use as orthodontic anchorage devices with demonstrated stability. The focus of this study is to develop and simulate operative factors, such as load magnitudes and anchor locations to achieve desired motions in a patient-specific 3D model undergoing orthodontic treatment with miniscrew implant anchorage. A CT scan of a patient skull was imported into Mimics software (Materialise, 12.1). Segmentation operations were performed on the images to isolate the mandible, filter out noise, then reconstruct a smooth 3D model. A model of the left canine was reconstructed with the PDL modeled as a thin solid layer. A miniscrew was modeled with dimensions based on a clinical implant (BMK OAS-T1207) then inserted into the posterior mandible. All components were volumetrically meshed and optimized in Mimics software. Elements comprising the mandible bone and teeth were assigned a material based on their gray value ranges in HU from the original scan, and meshes were exported into ANSYS software. All materials were defined as linear and isotropic. A nonlinear PDL was also defined for comparison. For transverse forces applied on the miniscrew, maximum stresses increased linearly with loading and appeared at the neck or first thread and in the cortical bone. A distal tipping force was applied on the canine, and maximum stresses appeared in the tooth at the crown and apex and in the bone at the compression surface. Under maximum loading, stresses in bone were sufficient for resorption. The nonlinear PDL exhibited lower stresses and deflections than the linear model due to increasing stiffness. Numerous stress concentrations were seen in all models. Results of this study demonstrate the potential of patient-specific 3D reconstruction from CT scans and finite-element simulation as a versatile and effective pre-operative planning tool for orthodontists.
Skip Nav Destination
ASME 2009 International Mechanical Engineering Congress and Exposition
November 13–19, 2009
Lake Buena Vista, Florida, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4375-8
PROCEEDINGS PAPER
Patient-Specific 3D Finite-Element Analysis of Miniscrew Implants During Orthodontic Treatment
Hussein H. Ammar,
Hussein H. Ammar
West Virginia University, Morgantown, WV
Search for other works by this author on:
Victor H. Mucino,
Victor H. Mucino
West Virginia University, Morgantown, WV
Search for other works by this author on:
Peter Ngan,
Peter Ngan
West Virginia University, Morgantown, WV
Search for other works by this author on:
Richard J. Crout,
Richard J. Crout
West Virginia University, Morgantown, WV
Search for other works by this author on:
Osama M. Mukdadi
Osama M. Mukdadi
West Virginia University, Morgantown, WV
Search for other works by this author on:
Hussein H. Ammar
West Virginia University, Morgantown, WV
Victor H. Mucino
West Virginia University, Morgantown, WV
Peter Ngan
West Virginia University, Morgantown, WV
Richard J. Crout
West Virginia University, Morgantown, WV
Osama M. Mukdadi
West Virginia University, Morgantown, WV
Paper No:
IMECE2009-13068, pp. 109-112; 4 pages
Published Online:
July 8, 2010
Citation
Ammar, HH, Mucino, VH, Ngan, P, Crout, RJ, & Mukdadi, OM. "Patient-Specific 3D Finite-Element Analysis of Miniscrew Implants During Orthodontic Treatment." Proceedings of the ASME 2009 International Mechanical Engineering Congress and Exposition. Volume 2: Biomedical and Biotechnology Engineering. Lake Buena Vista, Florida, USA. November 13–19, 2009. pp. 109-112. ASME. https://doi.org/10.1115/IMECE2009-13068
Download citation file:
7
Views
0
Citations
Related Proceedings Papers
Related Articles
Probing the Influence of Hybrid Thread Design On Biomechanical Response of Dental Implants: Finite Element Study and Experimental Validation
J Biomech Eng (January,0001)
Related Chapters
Understanding the Problem
Design and Application of the Worm Gear
Proper Generalized Decomposition Based Model Order Reduction Applied to Problems Defined in Degenerated Domains
Advances in Computers and Information in Engineering Research, Volume 2
Reducing Cache Contention of L2 Shared Cache on Multi-Core Processor Architecture
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3