It is important to have a quantitative method to establish a standard way to measure stability and osseointegration of implants. Among other benefits, these measurements would provide information leading to the prediction of healing time around the implant and the monitoring of the health of the implant’s interface. The dental industry has been looking for non-destructive methods to measure implant integration within the bone. In previous studies, resonance frequency analysis revealed a clear relationship between resonance frequency measurements and stiffness of the implant interface and the effective length of the implant. These studies have examined only one mode of vibration or have suffered from measurement difficulties. Furthermore, no study has evaluated the damping properties of the interface and surrounding tissues. This paper describes the development of an instrument capable of capturing and measuring information to characterize the process of dental implant osseointergration. The parameters needed to measure stability and osseointegration of implants are the stiffness of the implant components (which are a function of their geometry and material composition) and the stiffness and damping properties of the implant-bone interface and surrounding tissues. The instrument developed provides valuable information about the stiffness and damping properties of the implant-bone interface obtained through resonance frequency analysis with torsional, longitudinal and transverse vibration. Experimental, analytical, and finite element analysis results are presented.
Skip Nav Destination
ASME 2002 International Mechanical Engineering Congress and Exposition
November 17–22, 2002
New Orleans, Louisiana, USA
Conference Sponsors:
- Nondestructive Evaluation Division
ISBN:
0-7918-3649-5
PROCEEDINGS PAPER
Quantitative Determination of the Stability of Implant-Bone Interface Using Resonance Frequency Analysis
Daniel Delgado,
Daniel Delgado
University of Texas-Pan American, Edinburg, TX
Search for other works by this author on:
Arturo A. Fuentes,
Arturo A. Fuentes
University of Texas-Pan American, Edinburg, TX
Search for other works by this author on:
Robert Jones,
Robert Jones
University of Texas-Pan American, Edinburg, TX
Search for other works by this author on:
Arnold Lumsdaine
Arnold Lumsdaine
University of Tennesse at Knoxville, Knoxville, TN
Search for other works by this author on:
Daniel Delgado
University of Texas-Pan American, Edinburg, TX
Arturo A. Fuentes
University of Texas-Pan American, Edinburg, TX
Robert Jones
University of Texas-Pan American, Edinburg, TX
Arnold Lumsdaine
University of Tennesse at Knoxville, Knoxville, TN
Paper No:
IMECE2002-33490, pp. 103-111; 9 pages
Published Online:
June 3, 2008
Citation
Delgado, D, Fuentes, AA, Jones, R, & Lumsdaine, A. "Quantitative Determination of the Stability of Implant-Bone Interface Using Resonance Frequency Analysis." Proceedings of the ASME 2002 International Mechanical Engineering Congress and Exposition. Nondestructive Evaluation. New Orleans, Louisiana, USA. November 17–22, 2002. pp. 103-111. ASME. https://doi.org/10.1115/IMECE2002-33490
Download citation file:
3
Views
Related Proceedings Papers
Related Articles
Closure to “Discussion of ‘On Stability of Time-Varying Multidimensional Linear Systems’ ” [ASME J. Vibr. Acoust., 121 , No. 4, pp. 509–511 (1999)]
J. Vib. Acoust (July,2000)
Development and Validation of a Three-Dimensional Finite Element Model of the Face
J Biomech Eng (April,2009)
Non-linear Dynamic Modelling and Analysis of Split-Torque Face-Gear Drive Systems
J. Vib. Acoust (January,0001)
Related Chapters
Challenges in biomacromolecular delivery
Biocompatible Nanomaterials for Targeted and Controlled Delivery of Biomacromolecules
Contact (Joint) Stiffness and Damping
Handbook on Stiffness & Damping in Mechanical Design
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2