An automotive air conditioning system was subjected to varying percentages of oil in circulation (OIC) to investigate its impact on the evaporator, the condenser, and cycle performance. Since automotive air conditioning systems do not typically use oil separators, the compressor lubricant circulates through the system and effects evaporator, condenser and cycle performance. The OIC of the system was controlled by means of an oil separator installed in a parallel line at the compressor outlet allowing variable amounts of refrigerant to pass through the separator. The separated oil was returned upstream of the compressor inlet. It was found that the amount of OIC had an impact on the air conditioning system’s performance. The information presented allows the designer to judge the performance merits of installing an oil separator in an actual automotive air conditioning system of the type that was being simulated. The test system was built on a workbench to facilitate installation of various sensors to measure temperatures, pressures, relative humidity, flow rates, and power consumption. The workbench was placed across two environmental chambers such that the environmental conditions at the evaporator and condenser could be independently controlled. A test matrix of varying refrigerant flow rates, air flow rates, environmental conditions, and OIC were designed to simulate a range of car speed conditions that would be encountered in practice. An analysis was performed on the data collected from the workbench and the equations used in that analysis are presented in the paper. Although the results show some increase in heat transfer performance and cycle efficiency the overall improvements were moderate.
Skip Nav Destination
ASME 2004 Heat Transfer/Fluids Engineering Summer Conference
July 11–15, 2004
Charlotte, North Carolina, USA
Conference Sponsors:
- Heat Transfer Division and Fluids Engineering Division
ISBN:
0-7918-4693-8
PROCEEDINGS PAPER
The Effects of Oil in Circulation on the Performance of an Automotive Air Conditioning System
Pat T. Mackenzie,
Pat T. Mackenzie
Kansas State University, Manhattan, KS
Search for other works by this author on:
Paul A. Lebbin,
Paul A. Lebbin
Kansas State University, Manhattan, KS
Search for other works by this author on:
Steven J. Eckels,
Steven J. Eckels
Kansas State University, Manhattan, KS
Search for other works by this author on:
Mohammad H. Hosni
Mohammad H. Hosni
Kansas State University, Manhattan, KS
Search for other works by this author on:
Pat T. Mackenzie
Kansas State University, Manhattan, KS
Paul A. Lebbin
Kansas State University, Manhattan, KS
Steven J. Eckels
Kansas State University, Manhattan, KS
Mohammad H. Hosni
Kansas State University, Manhattan, KS
Paper No:
HT-FED2004-56778, pp. 179-187; 9 pages
Published Online:
February 24, 2009
Citation
Mackenzie, PT, Lebbin, PA, Eckels, SJ, & Hosni, MH. "The Effects of Oil in Circulation on the Performance of an Automotive Air Conditioning System." Proceedings of the ASME 2004 Heat Transfer/Fluids Engineering Summer Conference. Volume 4. Charlotte, North Carolina, USA. July 11–15, 2004. pp. 179-187. ASME. https://doi.org/10.1115/HT-FED2004-56778
Download citation file:
12
Views
Related Proceedings Papers
Related Articles
Bringing Automated Fault Detection and Diagnostics Tools for HVAC&R Into the Mainstream
J. Eng. Sustain. Bldgs. Cities (August,2020)
Characteristic Physical Parameter Approach to Modeling Chillers Suitable for Fault Detection, Diagnosis, and Evaluation
J. Sol. Energy Eng (August,2003)
Capacity Control for Refrigeration and Air-Conditioning Systems: A Comparative Study
J. Energy Resour. Technol (March,2001)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential