With a large capacity thermal storage system using phase change material (PCM), Concentrated Solar Power (CSP) is a promising technology for high efficiency of solar energy utilization. In a thermal storage system, a dual-media thermal storage tank is typically adopted in industry for the purpose of reducing the use of the heat transfer fluid (HTF). While the dual-media sensible heat storage system has been well studied, a dual-media latent heat storage system (LHSS) still needs more attention and study; particularly, the sizing of volumes of storage tanks considering actual operation conditions is of significance. In this paper, a strategy for LHSS volume sizing is proposed, which is based on computations using an enthalpy-based 1D model. One example of 60MW solar thermal power plant with 35% thermal efficiency is presented. In the study, potassium hydroxide (KOH) is adopted as PCM and Therminol VP-1 is used as HTF. The operational temperatures of the storage system are 390°C and 310°C, respectively for the high and low temperatures. The system is assumed to operate for 100 days with 6 hours charge and 6 hours discharge every day. From the study, the needed height of the thermal storage tank is calculated from using the strategy of tank sizing. The method for tank volume sizing is of significance to engineering application.