It has been well supported in the literature that using compression screws is the preferred method to achieve fixation of an arthrodesis [1, 2]. Indications for isolated subtalar arthrodesis include trauma, arthritis, talocalcaneal coalition, adult acquired flatfoot, posterior tibial tendon dysfunction, and Charcot neuroarthropathy [3, 4]. With the increase in bone screw shapes and designs, there is a desire to achieve the best compression generated by a type of screw so as to promote excellent bone healing and outcome for the patient; this will also allow the stability of the construct achieved by the screw and its placement to be determined. As indicated by Wheeler, et. al.[5] screw choice, compression, stability and loading can be very important when it comes to healing of fractures in small bones.
Skip Nav Destination
ASME 2008 3rd Frontiers in Biomedical Devices Conference
June 18–20, 2008
Irvine, California, USA
Conference Sponsors:
- Nanotechnology Institute
ISBN:
0-7918-4833-7
PROCEEDINGS PAPER
Bending, Torsional, and Pullout Strength of Compression Screws in Cadaver Foot and Ankle Specimens
Ferris M. Pfeiffer,
Ferris M. Pfeiffer
Brenoak Labs LLC, Columbia, MO
Search for other works by this author on:
Paul S. Shurnas,
Paul S. Shurnas
Columbia Orthopaedic Group; COG Clinical Research Group LLC, Columbia, MO
Search for other works by this author on:
Dennis L. Abernathie,
Dennis L. Abernathie
Brenoak Labs LLC; Columbia Orthopaedic Group; COG Clinical Research Group LLC, Columbia, MO
Search for other works by this author on:
James A. Ronan
James A. Ronan
COG Clinical Research Group LLC, Columbia, MO
Search for other works by this author on:
Ferris M. Pfeiffer
Brenoak Labs LLC, Columbia, MO
Paul S. Shurnas
Columbia Orthopaedic Group; COG Clinical Research Group LLC, Columbia, MO
Dennis L. Abernathie
Brenoak Labs LLC; Columbia Orthopaedic Group; COG Clinical Research Group LLC, Columbia, MO
James A. Ronan
COG Clinical Research Group LLC, Columbia, MO
Paper No:
BioMed2008-38064, pp. 21-22; 2 pages
Published Online:
June 5, 2009
Citation
Pfeiffer, FM, Shurnas, PS, Abernathie, DL, & Ronan, JA. "Bending, Torsional, and Pullout Strength of Compression Screws in Cadaver Foot and Ankle Specimens." Proceedings of the ASME 2008 3rd Frontiers in Biomedical Devices Conference. ASME 2008 3rd Frontiers in Biomedical Devices Conference. Irvine, California, USA. June 18–20, 2008. pp. 21-22. ASME. https://doi.org/10.1115/BioMed2008-38064
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
High Speed Fracture Fixation: Assessing Resulting Fixation Stability and Fastener Withdrawal Strength
J Biomech Eng (September,2013)
Factors Affecting the Pullout Strength of Cancellous Bone Screws
J Biomech Eng (August,1996)
An Instrumented Spacial Linkage for Monitoring Relative Three-Dimensional Motion Between Fracture Fragments
J Biomech Eng (November,1996)
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Aerial Image Classification Using Fuzzy Miner
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)
Crystallographic Analysis of Hydrogen-Related Fracture in Medium Carbon Martensitic Steel
International Hydrogen Conference (IHC 2012): Hydrogen-Materials Interactions