Biodegradable magnesium-calcium (MgCa) alloys are capable of gradually dissolving and becoming absorbed in the human body after implantation. The critical issue that hinders the application of MgCa implants is their fast corrosion rate in human body fluids. A promising approach to tackle this issue is to tailor surface integrity of orthopedic implants for tuning the corrosion kinetic. The synergistic dry cutting and burnishing is used in this study to modify surface integrity of MgCa0.8 (wt%) implants for controlled corrosion performance. The effects of cutting speed and rolling force, as key parameters in the synergistic dry cutting-finish burnishing, on the electrochemical responses of the processed surfaces are investigated in the simulated body fluid (SBF). Potentiodynamic polarization curves are measured, and morphology and elemental composition of corroded surfaces are studied utilizing scan electron microscopy (SEM) and energy dispersive spectroscopy (EDS), respectively.
Skip Nav Destination
ASME 2011 6th Frontiers in Biomedical Devices Conference
September 26–27, 2011
Irvine, California, USA
Conference Sponsors:
- Bioengineering Division
PROCEEDINGS PAPER
Effects of Surface Integrity on In-Vitro Corrosion of Biodegradable Magnesium-Calcium Orthopedic Implants
M. Salahshoor,
M. Salahshoor
The University of Alabama, Tuscaloosa, AL
Search for other works by this author on:
Y. B. Guo
Y. B. Guo
The University of Alabama, Tuscaloosa, AL
Search for other works by this author on:
M. Salahshoor
The University of Alabama, Tuscaloosa, AL
Y. B. Guo
The University of Alabama, Tuscaloosa, AL
Paper No:
BioMed2011-66003, pp. 21-22; 2 pages
Published Online:
July 18, 2013
Citation
Salahshoor, M, & Guo, YB. "Effects of Surface Integrity on In-Vitro Corrosion of Biodegradable Magnesium-Calcium Orthopedic Implants." Proceedings of the ASME 2011 6th Frontiers in Biomedical Devices Conference. ASME 2011 6th Frontiers in Biomedical Devices Conference and Exhibition. Irvine, California, USA. September 26–27, 2011. pp. 21-22. ASME. https://doi.org/10.1115/BioMed2011-66003
Download citation file:
3
Views
0
Citations
Related Proceedings Papers
Related Articles
Anodic Behavior of Specimens Prepared From a Full-Diameter Alloy 22 Fabricated Mockup Container for Nuclear Waste
J. Pressure Vessel Technol (November,2007)
Related Chapters
Joint Polarization Information for Fast Multi-Target Localization in Bistatic MIMO Radar System
International Symposium on Information Engineering and Electronic Commerce, 3rd (IEEC 2011)
The Study on Linear Component Technique in Identifying the Polarization of Electromagnetic Waves
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)
Mathematical Background
Vibrations of Linear Piezostructures